Utilization of superconducting magnetic energy storage and doubly fed induction generator for enhancing stability of interconnected power system

被引:2
|
作者
Kumar, Abdul Waheed [1 ]
Mufti, Mairaj Ud Din [1 ]
Zargar, Mubashar Yaqoob [2 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Srinagar, Jammu & Kashmir, India
[2] Islamic Univ Sci & Technol, Dept Elect Engn, Awantipora, Jammu & Kashmir, India
关键词
doubly fed induction generator; dynamic stability; eigenvalue analysis; superconducting magnetic energy storage; virtual synchronous generator; LARGE-SCALE; WIND FARM;
D O I
10.1002/cta.3699
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the share of wind power keeps on increasing, the interaction between synchronous and wind generators pose a challenging issue on power system stability. In order to investigate the impact of wind penetration on stability of power system, appropriate modeling of wind energy conversion systems (WECSs) is necessary. Moreover, it is needed to comprehensively study the impact of wind penetration on power system oscillations. This paper presents a didactic approach for integrating a doubly fed induction generator (DFIG)-based wind farm from SimPower Systems library to a five-area 68-bus power system modeled in Simulink. Inter-area oscillations with and without wind power penetration are investigated for their characteristics. Renewable energy sources are connected to the grid via power electronics converters at the cost of a reduction in inertia. The concept of virtual synchronous generator (VSG) produces virtual inertia by exchanging active power with the power system. The impact of superconducting magnetic energy storage (SMES) and DFIG on enhancing damping performance of inter-area is investigated. The increase in damping ratios of inter-area oscillatory modes verifies the enhancement in small signal stability by connecting SMES and DFIG to the power system. The usage of SMES operating in VSG mode to improve the dynamic stability with highly erratic wind profile is also investigated. The developed MATLAB/SIMULINK-based DFIG model is simple to use and can be expanded to build efficient controllers. The fidelity of the DFIG model and VSG technology is verified in real time by Opal-RT (OP4510).
引用
收藏
页码:5251 / 5268
页数:18
相关论文
共 50 条
  • [41] On the stability of power systems containing doubly fed induction generator-based generation
    Elkington, Katherine
    Enazkins, Valerijs
    Ghandhari, Mehrdad
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (09) : 1477 - 1484
  • [42] Control of Doubly Fed Induction Generator in Standalone Wind Energy Conversion System
    Sharma, Shailendra
    Singh, Bhim
    Chandra, A.
    Al-Haddad, K.
    2015 51ST IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2015,
  • [43] A DOUBLY-FED INDUCTION GENERATOR DRIVE FOR A WIND ENERGY CONVERSION SYSTEM
    Barendse, P. S.
    Pillay, P.
    SAIEE AFRICA RESEARCH JOURNAL, 2006, 97 (04): : 274 - 280
  • [44] Control of A Doubly-Fed Induction Generator for Wind Energy Conversion System
    Boubzizi, Said
    El Hajjaji, Ahmed
    Abid, Hafedh
    Chaabane, Mohamed
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 8773 - 8778
  • [45] A doubly-fed induction generator drive for a wind energy conversion system
    Barendse, P.S.
    Pillay, P.
    SAIEE Africa Research Journal, 2006, 97 (04) : 274 - 280
  • [46] Power system stability improvement using Superconducting Magnetic Energy Storage unit
    Abu-Siada, A
    Keerthipala, WWL
    Lawrance, WB
    IPEC 2003: PROCEEDINGS OF THE 6TH INTERNATIONAL POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2003, : 6 - 11
  • [47] Superconducting Magnetic Energy Storage Control Strategy for Power System Stability Improvement
    Griffo, Antonio
    lauria, DaviDe
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2005, 4 (01):
  • [48] Impact of inertia response control strategy based doubly fed induction generator on frequency stability of power system
    Zhang, Jialin
    Wei, Ping
    Gao, Xin
    ENERGY REPORTS, 2023, 9 : 577 - 583
  • [49] Impact of inertia response control strategy based doubly fed induction generator on frequency stability of power system
    Zhang, Jialin
    Wei, Ping
    Gao, Xin
    ENERGY REPORTS, 2023, 9 : 577 - 583
  • [50] Mining and Utilization of Reactive Power Capability of Doubly fed Induction Generator Systems for Wind Turbines
    Huang Ya-feng
    Yan Gan-gui
    Chao Chu-yan
    Mu Gang
    Zhang Zhen-qing
    Xu Fei
    Zhang Cheng-xin
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1579 - +