Quantification of spinal bone marrow fat fraction using three-material decomposition technique on dual-energy CT: A phantom study

被引:0
|
作者
Li, Baojun [1 ,2 ]
Hua, Ning [1 ]
Li, Janelle [1 ]
Andreu-Arasa, V. Carlota [1 ]
LeBedis, Christina [1 ]
Anderson, Stephan W. [1 ]
机构
[1] Boston Univ, Dept Radiol, Sch Med, Boston, MA USA
[2] Boston Univ, Dept Radiol, Sch Med, 820 Harrison Ave,FGH BLDG,3rd Floor, Boston, MA 02118 USA
关键词
bone edema; CT; dual-energy; fat fraction; three-material decomposition; MINERAL DENSITY; IN-VIVO; MRI; FRACTURES; ACCURACY; LESIONS; EDEMA;
D O I
10.1002/mp.16442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTwo-material decomposition is insufficient to quantify the fat fraction of spinal bone marrow, which is comprised of a mixture of bone minerals, water, and yellow marrow (fat). PurposeTo develop an accurate three-material decomposition-based bone marrow fat fraction (FF3MD$F{F_{3MD}}$) quantification technique for dual-energy CT. MethodsBone marrow edema phantoms containing trabecular bone minerals, water, and fat were constructed using fat fractions and bone mineral density values matching those expected in healthy and edematous bone, and scanned on a commercial dual-energy CT. Fat quantified by FF3MD$F{F_{3MD}}$ were compared to MRI-based fat fraction (FFMRI$F{F_{MRI}}$) and conventional two-material-decomposition-based fat fraction (FF2MD$F{F_{2MD}}$) to evaluate its accuracy and dependency on various bone mineral densities. ResultsFF3MD$F{F_{3MD}}$ demonstrated an excellent correlation with FFMRI$F{F_{MRI}}\;$(r = 0.97, R-2 = 0.96) in the phantom, significantly more accurate than FF2MD when confounding bone minerals are present (50 mg/cm(3): r = 1.02, R-2 = 0.95 vs. r = 0.65, R-2 = 0.79 (p < 0.01); 100 mg/cm(3): r = 0.81, R-2 = 0.47 vs. r = 0.21, R-2 = 0.21 (p < 0.05)). ConclusionsFF3MD$F{F_{3MD}}$ accurately quantified bone marrow fat fraction, when compared with FFMRI$F{F_{MRI}}$, in the specially constructed bone marrow phantom.
引用
收藏
页码:4105 / 4111
页数:7
相关论文
共 50 条
  • [31] Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses
    Chandarana, Hersh
    Megibow, Alec J.
    Cohen, Benjamin A.
    Srinivasan, Ramya
    Kim, Danny
    Leidecker, Christianne
    Macari, Michael
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W693 - W700
  • [32] Dual-Energy CT for Quantification of Urinary Stone Composition in Mixed Stones: A Phantom Study
    Leng, Shuai
    Huang, Alice
    Cardona, Juan Montoya
    Duan, Xinhui
    Williams, James C.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (02) : 321 - 329
  • [33] Three-material decomposition with dual-layer spectral CT compared to MRI for the detection of bone marrow edema in patients with acute vertebral fractures
    Benedikt J. Schwaiger
    Alexandra S. Gersing
    Johannes Hammel
    Kai Mei
    Felix K. Kopp
    Jan S. Kirschke
    Ernst J. Rummeny
    Klaus Wörtler
    Thomas Baum
    Peter B. Noël
    Skeletal Radiology, 2018, 47 : 1533 - 1540
  • [34] Image domain dual material decomposition for dual-energy CT using butterfly network
    Zhang, Wenkun
    Zhang, Hanming
    Wang, Linyuan
    Wang, Xiaohui
    Hu, Xiuhua
    Cai, Ailong
    Li, Lei
    Niu, Tianye
    Yan, Bin
    MEDICAL PHYSICS, 2019, 46 (05) : 2037 - 2051
  • [35] Optimising dual-energy CT scan parameters for virtual non-calcium imaging of the bone marrow: a phantom study
    Felix C. Müller
    Henrik Børgesen
    Kasper Gosvig
    Anders Rodell
    Christian Booz
    Bernhard Schmidt
    Bernhard Krauss
    Mikael Boesen
    European Radiology Experimental, 3
  • [36] Optimising dual-energy CT scan parameters for virtual non-calcium imaging of the bone marrow: a phantom study
    Mueller, Felix C.
    Borgesen, Henrik
    Gosvig, Kasper
    Rodell, Anders
    Booz, Christian
    Schmidt, Bernhard
    Krauss, Bernhard
    Boesen, Mikael
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01)
  • [37] The accuracy of bone mineral density measurement using dual-energy spectral CT and quantitative CT: a comparative phantom study
    Li, X.
    Li, J.
    Jiao, X.
    Jia, X.
    Zhang, X.
    Fan, G.
    Yang, J.
    Guo, J.
    CLINICAL RADIOLOGY, 2020, 75 (04) : 320.e9 - 320.e15
  • [38] Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
    Wang, Xu
    Li, Beibei
    Tong, Xiaoyu
    Fan, Yong
    Wang, Shigeng
    Liu, Yijun
    Fang, Xin
    Liu, Lei
    DIAGNOSTICS, 2023, 13 (10)
  • [39] Multivendor comparison of quantification accuracy of effective atomic number by Dual-Energy CT: A phantom study
    Qin, Tian
    Wang, Mengting
    Fan, Yihan
    Wang, Jing
    Gao, Zhizhen
    Wang, Fan
    Li, Ruomei
    Li, Kui
    Ruan, Chengcheng
    Liang, Baohui
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 180
  • [40] Improvement with the Multi-material Decomposition Framework in Dual-energy Computed Tomography: A Phantom Study
    Lee, Haenghwa
    Kim, Hee-Joung
    Lee, Donghoon
    Kim, Dohyeon
    Choi, Seungyeon
    Lee, Minjae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (06) : 515 - 523