Quantification of spinal bone marrow fat fraction using three-material decomposition technique on dual-energy CT: A phantom study

被引:0
|
作者
Li, Baojun [1 ,2 ]
Hua, Ning [1 ]
Li, Janelle [1 ]
Andreu-Arasa, V. Carlota [1 ]
LeBedis, Christina [1 ]
Anderson, Stephan W. [1 ]
机构
[1] Boston Univ, Dept Radiol, Sch Med, Boston, MA USA
[2] Boston Univ, Dept Radiol, Sch Med, 820 Harrison Ave,FGH BLDG,3rd Floor, Boston, MA 02118 USA
关键词
bone edema; CT; dual-energy; fat fraction; three-material decomposition; MINERAL DENSITY; IN-VIVO; MRI; FRACTURES; ACCURACY; LESIONS; EDEMA;
D O I
10.1002/mp.16442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTwo-material decomposition is insufficient to quantify the fat fraction of spinal bone marrow, which is comprised of a mixture of bone minerals, water, and yellow marrow (fat). PurposeTo develop an accurate three-material decomposition-based bone marrow fat fraction (FF3MD$F{F_{3MD}}$) quantification technique for dual-energy CT. MethodsBone marrow edema phantoms containing trabecular bone minerals, water, and fat were constructed using fat fractions and bone mineral density values matching those expected in healthy and edematous bone, and scanned on a commercial dual-energy CT. Fat quantified by FF3MD$F{F_{3MD}}$ were compared to MRI-based fat fraction (FFMRI$F{F_{MRI}}$) and conventional two-material-decomposition-based fat fraction (FF2MD$F{F_{2MD}}$) to evaluate its accuracy and dependency on various bone mineral densities. ResultsFF3MD$F{F_{3MD}}$ demonstrated an excellent correlation with FFMRI$F{F_{MRI}}\;$(r = 0.97, R-2 = 0.96) in the phantom, significantly more accurate than FF2MD when confounding bone minerals are present (50 mg/cm(3): r = 1.02, R-2 = 0.95 vs. r = 0.65, R-2 = 0.79 (p < 0.01); 100 mg/cm(3): r = 0.81, R-2 = 0.47 vs. r = 0.21, R-2 = 0.21 (p < 0.05)). ConclusionsFF3MD$F{F_{3MD}}$ accurately quantified bone marrow fat fraction, when compared with FFMRI$F{F_{MRI}}$, in the specially constructed bone marrow phantom.
引用
收藏
页码:4105 / 4111
页数:7
相关论文
共 50 条
  • [1] Quantification of Spinal Bone Marrow Fat Fraction Using Three-Material Decomposition Technique on Dual-Energy CT: A Feasibility Study
    Li, B.
    Hua, N.
    Li, J.
    Andreu-arasa, V.
    Lebedis, C.
    Anderson, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Fat Fraction Measurements Using a Three-Material Decomposition Dual-Energy CT Technique Accounting for Bone Minerals: Evaluation in a Bone Marrow Phantom Using MRI as Reference
    Li, Baojun
    Hua, Ning
    Li, Janelle
    Andreu-Arasa, V. Carlota
    LeBedis, Christina
    Anderson, Stephan W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (03) : 553 - 554
  • [3] Quantitative imaging of element composition and mass fraction using dual-energy CT: Three-material decomposition
    Liu, Xin
    Yu, Lifeng
    Primak, Andrew N.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (05) : 1602 - 1609
  • [4] Comparison of image and data domain methods for three-material decomposition in dual-energy CT
    Humphries, T.
    McGarity, R.
    Uy, K.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [5] Model-based three-material decomposition in dual-energy CT using the volume conservation constraint
    Liu, Stephen Z.
    Tivnan, Matthew
    Osgood, Greg M.
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    Zbijewski, Wojciech
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14):
  • [6] Feasibility study of three-material decomposition in dual-energy cone-beam CT imaging with deep learning
    Zhu, Jiongtao
    Su, Ting
    Zhang, Xin
    Yang, Jiecheng
    Mi, Donghua
    Zhang, Yunxin
    Gao, Xiang
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14):
  • [7] Accurate Multi-Material Decomposition in Dual-Energy CT: A Phantom Study
    Xue, Yi
    Jiang, Yangkang
    Yang, Chunlin
    Lyu, Qihui
    Wang, Jing
    Luo, Chen
    Zhang, Luhan
    Desrosiers, Catherine
    Feng, Kun
    Sun, Xiaonan
    Hu, Xiuhua
    Sheng, Ke
    Niu, Tianye
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2019, 5 (04) : 515 - 529
  • [8] Hepatic fat quantification in dual-layer computed tomography using a three-material decomposition algorithm
    Demondion, Emilie
    Ernst, Olivier
    Louvet, Alexandre
    Robert, Benjamin
    Kafri, Galit
    Langzam, Eran
    Vermersch, Mathilde
    EUROPEAN RADIOLOGY, 2024, 34 (06) : 3708 - 3718
  • [9] Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT
    Salas-Ramirez, Maikol
    Tran-Gia, Johannes
    Gbureck, Uwe
    Kosmala, Aleksander
    Lassmann, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20):
  • [10] Quantification of the Fat Fraction in the Liver Using Dual-Energy Computed Tomography and Multimaterial Decomposition
    Hur, Bo Yun
    Lee, Jeong Min
    Hyunsik, Woo
    Lee, Kyung Bun
    Joo, Ijin
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 845 - 852