Uncertainty method and sensitivity analysis for assessment of energy consumption of underground metro station

被引:46
|
作者
Kong, Gangqiang [1 ]
Hu, Shuaijun [1 ]
Yang, Qing [2 ]
机构
[1] Hohai Univ, Minist Educ Geomech & Embankment Engn, Key Lab, Xikang Rd 1, Nanjing 210024, Peoples R China
[2] Dalian Univ Technol, Sch Civil Engn, Dalian 116024, Peoples R China
基金
中国国家自然科学基金;
关键词
Shallow geothermal energy; Underground metro station; Energy consumption; Uncertainty; Sensitivity; COOLING LOAD; MODELS;
D O I
10.1016/j.scs.2023.104504
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An accurate calculation of energy consumption is a precondition for energy underground metro station design, which determines the amount of energy geostructure. This study develops a simplified deterministic method for the underground metro station energy performance that accounts for weather and interior heat gain uncertainty. A Monte Carlo technique with Latin hypercube sampling is then employed to confirm the probability distributions of the peak load, average yearly load and annual energy demand, and compared to deterministic method to improve the design robustness. The sensitivities of 14 input variables with respect to the underground metro station energy performance are discussed through three sensitivity methods. The simplified deterministic method is more accurate than the DeST and American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) in describing the fluctuation of the underground metro station energy performance. The uncertainty distribution of energy performance is advantageous to the system design, considering both safety and economy. Moreover, a comparison with the deterministic method is performed to determine the reasonability of the safety factor 1.2, which is usually used in practical programs. The peak load is dominated by outdoor parameters, while there are no control parameters for the average yearly load or annual energy demand.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Uncertainty and sensitivity analysis of energy assessment for office buildings based on Dempster-Shafer theory
    Tian, Wei
    de Wilde, Pieter
    Li, Zhanyong
    Song, Jitian
    Yin, Baoquan
    ENERGY CONVERSION AND MANAGEMENT, 2018, 174 : 705 - 718
  • [42] Analysis of the factors influencing energy consumption of a passenger transport station
    Meng, Xing-kai
    Yan, Zhao
    Heng, Wei-wei
    Zeng, Cheng
    GREEN BUILDING, ENVIRONMENT, ENERGY AND CIVIL ENGINEERING, 2017, : 257 - 260
  • [43] A calculation method for infiltration airflow in underground metro station equipment rooms based on pressure fluctuation characteristics: A case study
    Nie, Yining
    Huang, Yixiang
    Li, Zhixuan
    Liu, Moyun
    Lai, Yongjiu
    Su, Xing
    BUILDING AND ENVIRONMENT, 2025, 274
  • [44] PBK modelling assessment - uncertainty and sensitivity analysis characterisation
    Loizou, G.
    TOXICOLOGY LETTERS, 2023, 384 : S7 - S7
  • [45] Application of fuzzy set pair analysis method in ship energy consumption assessment
    Wang Yuguo
    PROCEEDINGS OF THE 2017 IEEE INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND ENGINEERING (IEEE-ICICE 2017), 2017, : 569 - 572
  • [46] Estimating Energy Consumption of Mine Fans in Underground Mines in Case of Uncertainty of Fan Influence Zones
    A. V. Kashnikov
    Yu. V. Kruglov
    Journal of Mining Science, 2022, 58 : 588 - 598
  • [47] Estimating Energy Consumption of Mine Fans in Underground Mines in Case of Uncertainty of Fan Influence Zones
    Kashnikov, A. V.
    Kruglov, Yu. V.
    JOURNAL OF MINING SCIENCE, 2022, 58 (04) : 588 - 598
  • [48] Uncertainty and sensitivity analysis for the simulation of a station blackout scenario in the Jules Horowitz Reactor
    Ghione, Alberto
    Noel, Brigitte
    Vinai, Paolo
    Demaziere, Christophe
    ANNALS OF NUCLEAR ENERGY, 2017, 104 : 28 - 41
  • [49] AN UNCERTAINTY AND SENSITIVITY ANALYSIS TOOL FOR BUILDING THERMAL ENERGY CONSUMPTION: A PERFORMANCE COMPREHENSION OF STATIC AND DYNAMIC RESPONSE ANALYSES
    Koosha, Rasool
    Shahsavari, Fatemeh
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2019, VOL 1, 2020,
  • [50] Energy consumption and travel time analysis for metro lines with express/local mode
    Gao, Yuan
    Yang, Lixing
    Gao, Ziyou
    TRANSPORTATION RESEARCH PART D-TRANSPORT AND ENVIRONMENT, 2018, 60 : 7 - 27