Usefulness of differential time to positivity between catheter and peripheral blood cultures for diagnosing catheter-related bloodstream infection: Data analysis from routine clinical practice in the intensive care unit

被引:8
|
作者
Bisanti, Alessandra [1 ,2 ]
Giammatteo, Valentina [2 ]
Bello, Giuseppe [1 ,2 ,7 ]
Giannarelli, Diana [3 ]
Montini, Luca [1 ,2 ]
Tanzarella, Eloisa S. [1 ,2 ]
Carelli, Simone [1 ,2 ]
Bongiovanni, Filippo [1 ,2 ]
D'Inzeo, Tiziana [4 ,5 ]
Fiori, Barbara [4 ,5 ,6 ]
Grieco, Domenico L. [1 ,2 ]
Pennisi, Mariano A. [1 ,2 ]
De Pascale, Gennaro [1 ,2 ]
Antonelli, Massimo
机构
[1] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Sci Emergenza Anestesiol & Rianimaz, UOC Anestesia Rianimaz Terapia Intens & Tossicol, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Ist Anestesia & Rianimaz, Rome, Italy
[3] Fdn Policlin Univ Agostino Gemelli IRCCS, Facil Epidemiol & Biostat GSTeP, Rome, Italy
[4] Fdn Policlin Univ Agostino Gemelli IRCCS, Dipartimento Sci Lab & Infettivol, Rome, Italy
[5] Univ Cattolica Sacro Cuore, Ist Microbiol, Rome, Italy
[6] Scuola Prov Super Sanita Claudiana, Bolzano, Italy
[7] Univ Cattolica Sacro Cuore, Fdn Policlin Univ Agostino Gemelli IRCCS, Ist Anestesia & Rianimaz, Largo A Gemelli 8, I-00168 Rome, Italy
关键词
Central venous catheters; Catheter-related infections; Diagnosis; Intensive care units; SHORT-TERM; HUB-BLOOD; SEPSIS; BACTEREMIA; GUIDELINES; PREVENTION; MANAGEMENT; COHORT; SITE;
D O I
10.1016/j.jcrc.2023.154259
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To assess the accuracy of differential time to positivity (DTP) method for the diagnosis of catheterrelated bloodstream infections (CRBSI) in the routine practice of our intensive care unit (ICU).Materials and methods: Over a five-year study period, ICU patients with a central venous catheter in place for >= 48 h and undergoing DTP test with catheter tip culture were analyzed. We investigated: the accuracy of DTP test with the usual threshold of 120 min in confirming the clinical suspicion of CRBSI; the most accurate threshold value of DTP to detect CRBSI; the diagnostic accuracy of the ratio (rather than the difference) between times to positivity.Results: Among 278 episodes of paired blood cultures, 13% were CRBSIs. DTP value >= 120 min used for the diagnosis of CRBSI yielded 41% sensitivity and 74% specificity. Performance of DTP values in predicting CRBSI was low (AUC = 0.60 [95%CI: 0.48-0.72]). Cutoff value of the ratio between times to positivity was 0.80, with 46% sensitivity and 79% specificity.Conclusions: The routine use of the DTP method at any cutoff point has inadequate accuracy in detecting CRBSI in the real every day clinical practice. Not even the ratio between times to positivity seems to be clinically useful.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Difference in time to positivity of hub-blood versus nonhub-blood cultures is not useful for the diagnosis of catheter-related bloodstream infection in critically ill patients
    Rijnders, BJA
    Verwaest, C
    Peetermans, WE
    Wilmer, A
    Vandecasteele, S
    Van Eldere, J
    Van Wijngaerden, E
    CRITICAL CARE MEDICINE, 2001, 29 (07) : 1399 - 1403
  • [32] Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures
    Blot, F
    Nitenberg, G
    Chachaty, E
    Raynard, B
    Germann, N
    Antoun, S
    Laplanche, A
    Brun-Buisson, C
    Tancrede, C
    LANCET, 1999, 354 (9184): : 1071 - 1077
  • [33] Sensitivity of differential time to positivity compared to pour plates for diagnosing catheter-related blood stream infection: An evaluation in patients with chronic intestinal failure
    Chadwick, Paul R.
    Ryan, Kate
    Teubner, Antje
    Bond, Ashley
    Abraham, Arun
    Lal, Simon
    CLINICAL NUTRITION, 2020, 39 (08) : 2631 - 2633
  • [34] High positive predictive value of Gram stain on catheter-drawn blood samples for the diagnosis of catheter-related bloodstream infection in intensive care neonates
    M. Deleers
    M. Dodémont
    B. Van Overmeire
    Y. Hennequin
    D. Vermeylen
    S. Roisin
    O. Denis
    European Journal of Clinical Microbiology & Infectious Diseases, 2016, 35 : 691 - 696
  • [35] High positive predictive value of Gram stain on catheter-drawn blood samples for the diagnosis of catheter-related bloodstream infection in intensive care neonates
    Deleers, M.
    Dodemont, M.
    Van Overmeire, B.
    Hennequin, Y.
    Vermeylen, D.
    Roisin, S.
    Denis, O.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2016, 35 (04) : 691 - 696
  • [36] Reduced intravascular catheter-related infection by routine use of antibiotic-bonded catheters in a surgical intensive care unit
    Kamal, GD
    Divishek, D
    Kumar, GC
    Porter, BR
    Tatman, DJ
    Adams, JR
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1998, 30 (03) : 145 - 152
  • [37] AN EDUCATION-BASED INTERVENTION REDUCES CATHETER-RELATED BLOODSTREAM INFECTION IN THE INTENSIVE CARE UNIT AND CHANGES PUNCTURE SITE PREFERENCE
    Vos, P.
    Verhoeven, T.
    Speelberg, B.
    INTENSIVE CARE MEDICINE, 2009, 35 : 262 - 262
  • [38] Nudge to better care - blood cultures and catheter-related bloodstream infections in Germany at two points in time (2006, 2015)
    Florian Salm
    Frank Schwab
    Michael Behnke
    Frank M. Brunkhorst
    André Scherag
    Christine Geffers
    Petra Gastmeier
    Antimicrobial Resistance & Infection Control, 7
  • [39] Cost Savings From Reduced Catheter-Related Bloodstream Infection After Simulation-Based Education for Residents in a Medical Intensive Care Unit
    Cohen, Elaine R.
    Feinglass, Joe
    Barsuk, Jeffrey H.
    Barnard, Cynthia
    O'Donnell, Anna
    McGaghie, William C.
    Wayne, Diane B.
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2010, 5 (02): : 98 - 102
  • [40] Evaluation of the usefulness of a quantitative blood culture in the diagnosis of catheter-related bloodstream infection: Comparative analysis of two periods (2002 and 2012)
    Maria Planes, Anna
    Calleja, Raquel
    Bernet, Albert
    Campins-Marti, Magda
    Almirantec, Benito
    Pumarola, Tomas
    Fernandez-Hidalgos, Nuria
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2016, 34 (08): : 484 - 489