PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables

被引:3
|
作者
Kaziz, Sinda [1 ,2 ]
Romano, Pietro [3 ]
Imburgia, Antonino [3 ]
Ala, Guido [3 ]
Sghaier, Halim [2 ]
Flandre, Denis [4 ]
Tounsi, Fares [1 ,4 ]
机构
[1] Univ Sfax, Ecole Natl Ingenieurs Sfax, SI2E Lab, Sfax 3038, Tunisia
[2] Univ Monastir, Fac Sci Monastir, Monastir 5019, Tunisia
[3] Univ Palermo, Dept Engn, LEPRE HV Lab, I-90128 Palermo, Italy
[4] Catholic Univ Louvain, ICTEAM Inst, SMALL Grp, B-1348 Louvain La Neuve, Belgium
关键词
inductive loops; PCB-based inductors; partial discharges; defects detection; HV power cables; INSULATION; SENSORS; MV;
D O I
10.3390/s23010290
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors' outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] PCB-Based Current Sensor Design for Sensing Switch Current of a Nonmodular GaN Power Semiconductor
    Kim, Ui-Jin
    Song, Min-Soo
    Kim, Rae-Young
    ENERGIES, 2020, 13 (19)
  • [32] Compact Two-Phase Immersion Cooling With Dielectric Fluid for PCB-Based Power Electronics
    Ristic-Smith, Aleksandar
    Rogers, Daniel J.
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2024, 5 : 1107 - 1118
  • [33] Multiplex PCB-based electrochemical detection of cancer biomarkers using MLPA-barcode approach
    Acero Sanchez, J. L.
    Henry, O. Y. F.
    Joda, H.
    Solnestam, B. Werne
    Kvastad, L.
    Johansson, E.
    Akan, P.
    Lundeberg, J.
    Lladach, N.
    Ramakrishnan, D.
    Riley, I.
    O'Sullivan, C. K.
    BIOSENSORS & BIOELECTRONICS, 2016, 82 : 224 - 232
  • [34] Inductive Sensor Performance in Partial Discharges and Noise Separation by Means of Spectral Power Ratios
    Alfredo Ardila-Rey, Jorge
    Victoria Rojas-Moreno, Monica
    Manuel Martinez-Tarifa, Juan
    Robles, Guillermo
    SENSORS, 2014, 14 (02) : 3408 - 3427
  • [35] Comparison of capacitive and inductive sensors designed for partial discharges measurements in electrical power apparatus
    Kunicki, Michal
    INTERNATIONAL CONFERENCE ENERGY, ENVIRONMENT AND MATERIAL SYSTEMS (EEMS 2017), 2017, 19
  • [36] Review on Detection and Analysis of Partial Discharge along Power Cables
    Zhang, Xiaohua
    Pang, Bo
    Liu, Yaxin
    Liu, Shaoyu
    Xu, Peng
    Li, Yan
    Liu, Yifan
    Qi, Leijie
    Xie, Qing
    ENERGIES, 2021, 14 (22)
  • [37] Detection of Multiple Partial Discharge Faults in Switchgear and Power Cables
    Hussain, Ghulam Amjad
    Hummes, Detlef
    Shafiq, Muhammad
    Safdar, Madia
    2019 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2019,
  • [38] A Finite Element Method based Approach for Modeling of Partial Discharges in HVDC Cables
    Anagha, E. R.
    Joseph, Jineeth
    Sindhu, T. K.
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 533 - 537
  • [39] A Transformerless PCB-Based Medium-Voltage Multilevel Power Converter With a DC Capacitor Balancing Circuit
    Solomon, Luke Anthony
    Permuy, Alfred
    Benavides, Nicholas D.
    Opila, Daniel F.
    Lee, Christopher J.
    Reed, Gregory F.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (04) : 3052 - 3067
  • [40] Investigating Conditions for an Unexpected Additional Source of Partial Discharges in DC Cables: Load Power Variations
    Naderiallaf, Hadi
    Seri, Paolo
    Montanari, Gian Carlo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (05) : 3082 - 3090