An efficient and green method for the analysis of synthetic cathinones in whole blood using 96-well electromembrane extraction and LC-MS/MS

被引:2
|
作者
Fabris, Andre L. [1 ]
Hansen, Frederik A. [2 ]
Yonamine, Mauricio [1 ]
Pedersen-Bjergaard, Stig [2 ,3 ]
Oiestad, Elisabeth L. [2 ,4 ]
机构
[1] Univ Sao Paulo, Sch Pharmaceut Sci, Ave Prof Lineu Prestes 580, Sao Paulo, Brazil
[2] Univ Oslo, Dept Pharm, Blindern, N-0316 Oslo, Norway
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Pharm, Univ Pk 2, DK-2100 Copenhagen, Denmark
[4] Oslo Univ Hosp, Div Lab Med, Dept Forens Sci, Oslo N-0424, Norway
来源
关键词
Electromembrane extraction; Synthetic cathinones; New psycoactive substances; LC-MS/MS; PSYCHOACTIVE SUBSTANCES; LIQUID-MEMBRANES; AUTOMATION; PLASMA;
D O I
10.1016/j.scp.2024.101494
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electromembrane extraction (EME) is a miniaturized technique in which charged molecules are extracted from biological samples, through a porous membrane, into an acceptor solution. This process occurs in the presence of an electric field that enables increased analyte recovery in short extraction times. Studies are being carried out to establish recommended extraction conditions for different groups of compounds based on their physicochemical properties. In this work, pre-established generic liquid membranes for the extraction of basic compounds were tested using synthetic cathinones within a wide log P range as basic model analytes. First, recommended organic solvents for the chosen analytes were evaluated in terms of recovery. The best candidates were included in an optimization study with other relevant EME conditions (voltage, extraction time, and agitation rate). All analyses were performed using a UPLC-MS/MS with the multiple reaction monitoring mode. 2-Undecanone was chosen as the liquid membrane providing the best extraction efficiency in combination with 40 V, 35 min, and 725 rpm. Validation showed r(2) > 0.99 in the 1-500 ng/mL range, accuracy of +/- 12%, imprecision of <= 19%, 1 ng/mL as limit of quantitation, 0.1-0.5 ng/mL as limit of detection, matrix effect 97-118%, and recovery 63-110%. Among the generic liquid membranes studied in this work, 2-Undecanone was the best choice for the target basic analytes. High recoveries and low matrix effects were achieved, thus demonstrating the applicability of recommended generic liquid membranes in the 96-well plate setup and with whole blood samples. Our findings contribute to further establishing EME as an actual sample preparation technique for routine analyses that could be further explored in a commercial format.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Development and validation of a GC–MS/MS method for the determination of 11 amphetamines and 34 synthetic cathinones in whole blood
    Mateusz Kacper Woźniak
    Laura Banaszkiewicz
    Marek Wiergowski
    Ewa Tomczak
    Marzena Kata
    Beata Szpiech
    Jacek Namieśnik
    Marek Biziuk
    Forensic Toxicology, 2020, 38 : 42 - 58
  • [42] Bradykinin analysis revived - A validated method for determination of its stable metabolite in whole blood by LC-MS/MS
    Seip, Knut F.
    Bjerknes, Kari C.
    Johansen, Harald T.
    Nielsen, Erik W.
    Landro, Linn
    Reubsaet, Leon
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 139 - 144
  • [43] A green analytical method for the determination of polyphenols in wine by dispersive pipette extraction and LC-MS/MS
    Pereira-Coelho, Marina
    Haas, Isabel Cristina da Silva
    Reinke, Cassia Katrin
    Dognini, Jocinei
    Amboni, Renata Dias de Mello Castanho
    Vitali, Luciano
    Madureira, Luiz Augusto dos Santos
    FOOD CHEMISTRY, 2023, 405
  • [44] A multi-analyte LC-MS/MS method for screening and quantification of 16 synthetic cathinones in hair: Application to postmortem cases
    Freni, Francesca
    Bianco, Sara
    Vignali, Claudia
    Groppi, Angelo
    Moretti, Matteo
    Osculati, Antonio Marco Maria
    Morini, Luca
    FORENSIC SCIENCE INTERNATIONAL, 2019, 298 : 115 - 120
  • [45] Phospholipid removal combined with a semi-automated 96-well SPE application for determination of budesonide in human plasma with LC-MS/MS
    Nilsson, Karin
    Andersson, Maria
    Beck, Olof
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 970 : 31 - 35
  • [46] Qualitative analysis of synthetic opioids, synthetic hallucinogens and LSD in urine using LC-MS/MS
    Ng, Xue Qin
    Hamzah, Asimah
    Goh, Mei Ling Evelyn
    Moy, Hooi Yan
    Yao, Yi Ju
    Lui, Chi Pang
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2019, 51 : S229 - S233
  • [47] A quantitative LC-MS/MS method for simultaneous determination of cocaine and its metabolites in whole blood
    Chen, Xiabin
    Zheng, Xirong
    Ding, Kai
    Zhou, Ziyuan
    Zhan, Chang-Guo
    Zheng, Fang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 : 243 - 251
  • [48] An Efficient, Robust Method for the Determination of Cannabinoids in Whole Blood by LC-MS-MS
    Tiscione, Nicholas B.
    Miller, Russell
    Shan, Xiaoqin
    Sprague, Jessica
    Yeatman, Dustin Tate
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (08) : 639 - 648
  • [49] An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study
    Pinto, Guilherme Araujo
    Fercondini Pastre, Katia Isabel
    Bellorio, Karini Bruno
    Teixeira, Leonardo de Souza
    de Souza, Weidson Carlo
    de Abreu, Fernanda Crunivel
    de Santana e Silva Cardoso, Fabiana Fernandes
    Pianetti, Gerson Antonio
    Cesar, Isabela Costa
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (09) : 1212 - 1218
  • [50] Development and validation of a LC-MS/MS method for the quantitation of lumefantrine in mouse whole blood and plasma
    Govender, Katya
    Gibhard, Liezl
    Du Plessis, Lissinda
    Wiesner, Lubbe
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 985 : 6 - 13