Non-diffractive, toric, extended depth-of-focus intraocular lenses in eyes with low corneal astigmatism

被引:0
|
作者
Pastor-Pascual, Francisco [1 ]
Orts-Vila, Paz [2 ]
Tana-Sanz, Pedro [2 ]
Tana-Sanz, Santiago [2 ]
Ruiz-Mesa, Ramon [3 ]
Tana-Rivero, Pedro [2 ]
机构
[1] Oftalvist, C Ruzafa 19, Valencia 46004, Spain
[2] Oftalvist, Alicante, Spain
[3] Oftalvist, Jerez de la Frontera, Spain
关键词
EDOF; Toric; Intraocular lens; Astigmatism; Cataract; CATARACT-SURGERY; PREVALENCE;
D O I
10.1186/s40662-024-00380-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To assess clinical outcomes after implanting toric, extended-depth-of-focus intraocular lenses (IOLs) to correct low corneal astigmatism in eyes with cataracts.Methods 47 eyes were implanted with the AcrySof IQ Vivity Toric DFT215 IOL. Main outcome measures were refractive error, monocular uncorrected and corrected distance (UDVA/CDVA), uncorrected and distance-corrected intermediate (UIVA/DCIVA), and uncorrected near and distance-corrected near (UNVA/DCNVA) visual acuities, monocular defocus curve, rotational stability, and IOLSAT and QUVID questionnaires. Patients were assessed at 3 months postsurgery.Results All eyes had a postoperative spherical equivalent (SE) within +/- 0.50 D and 97.87% (n = 46) had a refractive cylinder <= 0.50 D. The mean SE and refractive cylinder were - 0.10 +/- 0.17 D and - 0.16 +/- 0.24 D, respectively. The CDVA was >= 20/25 and >= 20/32 in 95.74% (n = 45) and 97.87% (n = 46) of eyes, respectively. The DCIVA was >= 20/32 in 85.11% (n = 40) of eyes and the DCNVA was >= 20/40 in 74.47% (n = 35). The mean values of CDVA, DCIVA, and DCNVA were - 0.02 +/- 0.08, 0.14 +/- 0.09, and 0.23 +/- 0.12 logMAR, respectively. The defocus curve revealed good visual acuity at far and intermediate distances with a depth-of-focus of about 1.75 D. IOL rotation was 0.74 +/- 1.13 degrees and all eyes had a rotation of less than 5 degrees. Patients reported either good or very good postoperative vision without eyeglasses under bright-light-conditions at distance (87.80%, 36/41) and intermediate distance (92.68%, 38/41). Between about 63.83%-72.34% (30-34) of patients reported no starburst, halos, or glare, or if experienced, were not bothersome.Conclusions The Vivity toric IOL implanted in eyes with low-astigmatism provides accurate refractive outcomes, good visual acuity at different distances and excellent rotational stability. Trial Registration The study was registered with the German Clinical Trials Register (DRKS00030579)Conclusions The Vivity toric IOL implanted in eyes with low-astigmatism provides accurate refractive outcomes, good visual acuity at different distances and excellent rotational stability. Trial Registration The study was registered with the German Clinical Trials Register (DRKS00030579)
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Non-toric extended depth of focus contact lenses for astigmatism and presbyopia correction
    Ben Yaish, Shai
    Zlotnik, Alex
    Yehezkel, Oren
    Lahav-Yacouel, Karen
    Belkin, Michael
    Zalevsky, Zeev
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [22] Correcting corneal astigmatism with toric intraocular lenses
    Findl O.
    Hirnschall N.
    Spektrum der Augenheilkunde, 2016, 30 (6) : 217 - 221
  • [23] Visual outcomes of non-diffractive extended-depth-of-focus and enhanced monofocal intraocular lenses: A case-control study
    Sabur, Huri
    Unsal, Ugur
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 262 - 268
  • [24] Visual performance comparison of 2 extended depth-of-focus intraocular lenses
    Schojai, Merita
    Schultz, Tim
    Jerke, Corinna
    Boecker, Jorg
    Dick, H. Burkhard
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (03): : 388 - 393
  • [25] Visualization of Ray Propagation through Extended Depth-of-Focus Intraocular Lenses
    Baur, Isabella D.
    Auffarth, Gerd U.
    Yan, Weijia
    Labuz, Grzegorz
    Khoramnia, Ramin
    DIAGNOSTICS, 2022, 12 (11)
  • [26] Toric intraocular lenses for correcting astigmatism in 130 eyes
    Sun, XY
    Vicary, D
    Montgomery, P
    Griffiths, M
    OPHTHALMOLOGY, 2000, 107 (09) : 1776 - 1781
  • [27] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Sakisaka, Toshihiro
    Minami, Keiichiro
    Takada, Keita
    Mori, Yosai
    Miyata, Kazunori
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [28] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Toshihiro Sakisaka
    Keiichiro Minami
    Keita Takada
    Yosai Mori
    Kazunori Miyata
    BMC Ophthalmology, 21
  • [29] Postoperative Visual Function of Extended Depth-of-Focus Intraocular Lenses Versus Monofocal Lenses
    Komatsu, Koji
    Masuda, Yoichiro
    Tachibana, Sei
    Sano, Kei
    Iida, Masanobu
    Ichihara, Kosuke
    Oki, Tetutaro
    Fukai, Kota
    Tatemichi, Masayuki
    Nakano, Tadashi
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (07) : E499 - +
  • [30] Effect of minimonovision in bilateral implantation of a novel non-diffractive extended depth-of-focus intraocular lens: Defocus curves, visual outcomes, and quality of life
    Coassin, Marco
    Mori, Tommaso
    Di Zazzo, Antonio
    Poddi, Maria
    Sgrulletta, Roberto
    Napolitano, Pasquale
    Bonini, Stefano
    Orfeo, Vincenzo
    Kohnen, Thomas
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2942 - 2948