Treatment of basilar artery aneurysms with two braided stents: Two centers experience of low-profile visualized intraluminal support stents versus Pipeline flow diverters

被引:0
|
作者
Luo, Bin [1 ]
Wang, Chao [2 ,3 ,4 ]
Liu, Jian [2 ,3 ,4 ]
Zhang, Yisen [2 ,3 ,4 ]
Wang, Kun [2 ,3 ,4 ]
Li, Wenqiang [2 ,3 ,4 ]
Zhang, Ying [2 ,3 ,4 ]
机构
[1] Peking Univ Int Hosp, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
[3] Capital Med Univ, Beijing Neurosurg Inst, Dept Neurosurg, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
[4] Capital Med Univ, Beijing Tiantan Hosp, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
来源
NEURORADIOLOGY JOURNAL | 2024年 / 37卷 / 04期
基金
中国国家自然科学基金;
关键词
Intracranial aneurysm; stent; basilar artery; treatment; SINGLE-CENTER EXPERIENCE; EMBOLIZATION;
D O I
10.1177/19714009241242638
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Both low-profile visualized intraluminal support (LVIS)stents and Pipeline flow diverters (FDs) are therapeutic strategies for basilar artery (BA) aneurysms, but they have not been directly compared.Methods A total of 132 consecutive patients with 139 BA aneurysms treated with either LVIS stent or Pipeline FDs were analyzed. Propensity score matching (PSM) was used to control for age, sex, hypertension, aneurysm size, shape, location, and duration of follow-up. The treatment results of these two braided stents were compared.Results LVIS stent was placed in 88 (63.3%) and Pipeline FDs in 51 (36.7%) procedures. Patients with Pipeline FDs tended to be younger and have less hypertension, whereas aneurysms had larger aneurysm size. After PSM, similar complete or near-complete occlusion rates (76.7% vs 73.3%, p = .766) and favorable functional outcomes (86.7% vs 90.0%, p = 1) were achieved in patients treated with LVIS stents and Pipeline FDs, respectively. Further comparisons were conducted at three different locations (basilar apex/basilar trunk/vertebrobasilar artery junction [VBJ]) separately, and the results showed a higher complete or near-complete aneurysm occlusion rate after Pipeline FD treatment than LVIS treatment (86.7% vs 59.2%, p = .012) only at VBJ, where a particularly high proportion of non-saccular shape (70.9%) and a male preponderance were noted.Conclusion Both braided stents were effective in the treatment of BA aneurysms, with good occlusion rates and favorable functional outcomes. Pipeline FD achieved a particularly higher aneurysm occlusion rate than LVIS stent at VBJ, where lesions often require reconstruction of the diseased vessel.
引用
收藏
页码:500 / 509
页数:10
相关论文
共 50 条
  • [11] Preliminary experience with the use of low profile visualized intraluminal support device in basilar artery for aneurysm treatment
    Wang, Chuanchuan
    Wu, Yina
    Feng, Zhengzhe
    Wang, Jing
    Li, Qiang
    Zhao, Rui
    Hong, Bo
    Xu, Yi
    Huang, Qinghai
    Fang, Yibin
    Liu, Jianmin
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (04) : 405 - 410
  • [12] Comparison of Two Endovascular Interventions with Low-Profile Visualized Intraluminal Support or Pipeline Embolization Device in Middle Cerebral Arterial Aneurysms Patients
    Lv, Zhonghua
    Zhu, Yong
    Wang, Wei
    Wu, Qiangjun
    Li, Wen
    Li, Qiang
    Xu, Liang
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (06) : 590 - 594
  • [13] Letter: Low-Profile Visualized Intraluminal Support Jr Braided Stent Versus Atlas Self-Expandable Stent for Treatment of Intracranial Aneurysms: A Single Center Experience
    Pongprasert, Sirinkaanta
    NEUROSURGERY, 2021, 89 (03) : E173 - E173
  • [14] Reconstructive endovascular treatment of vertebral artery dissecting aneurysms with the Low-profile Visualized Intraluminal Support (LVIS) device
    Wang, Chuan-Chuan
    Fang, Yi-Bin
    Zhang, Ping
    Zhu, Xuan
    Hong, Bo
    Xu, Yi
    Liu, Jian-Min
    Huang, Qing-Hai
    PLOS ONE, 2017, 12 (06):
  • [15] Intracranial Complex Ruptured Aneurysms Coiled with Overlapping Low-Profile Visualized Intraluminal Support Stents: Another Available Option for Complex Ruptured Intracranial Aneurysms
    Yan, Zhiyuan
    Zheng, Kuang
    Xiong, Ye
    Lan, Fujun
    Wang, Yunhui
    Tan, Xianxi
    Zhong, Ming
    Li, Zequn
    WORLD NEUROSURGERY, 2019, 125 : E22 - E28
  • [16] Endovascular treatment with the Enterprise stent versus the Neuroform or Low-Profile Visualized Intraluminal Support stent for unruptured aneurysms
    De Leacy, Reade
    Kottenmeier, Emilie
    Lee, Stephanie H. Y.
    Khanna, Rahul
    Spiotta, Alejandro M.
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2021, 10 (04) : 295 - 305
  • [17] Flow Diversion with Low-Profile Braided Stents for the Treatment of Very Small or Uncoilable Intracranial Aneurysms at or Distal to the Circle of Willis
    Aydin, K.
    Barburoglu, M.
    Sencer, S.
    Berdikhojayev, M.
    Coskun, B.
    Akpek, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (11) : 2131 - 2137
  • [18] Endovascular Treatment of Ruptured Tiny Intracranial Aneurysms with Low-Profile Visualized Intraluminal Support Device
    Wu, Pei
    Ocak, Pinar Eser
    Wang, Dianhong
    Ocak, Umut
    Xu, Shancai
    Li, Yuchen
    Zhang, Tongyu
    Shi, Huaizhang
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2019, 28 (02): : 330 - 337
  • [19] Endovascular treatment of PICA aneurysms with a Low-profile Visualized Intraluminal Support (LVIS Jr) device
    Samaniego, Edgar A.
    Abdo, German
    Hanel, Ricardo A.
    Lima, Andrey
    Ortega-Gutierrez, Santiago
    Dabus, Guilherme
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (10) : 1030 - 1033
  • [20] Treatment of wide-necked aneurysms with the Low-profile Visualized Intraluminal Support (LVIS Jr) device: a multicenter experience
    Grossberg, J. A.
    Hanel, R. A.
    Dabus, G.
    Keigher, K.
    Haussen, D. C.
    Sauvageau, E.
    Linfante, I.
    Gonsales, D.
    Salinas, P. Aguilar
    Bouslama, M.
    Mayich, M.
    Nogueira, R. G.
    Lopes, D. K.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (11) : 1098 - 1102