Potency and Powder X-ray Diffraction (PXRD) Evaluation of Levothyroxine Sodium Tablets under Ambient, Accelerated, and Stressed Conditions

被引:0
|
作者
Okezue, Mercy A. [1 ]
Byrn, Stephen R. [2 ]
Probost, Josiah [2 ]
Lucas, Madison [2 ]
Clase, Kari L. [3 ]
机构
[1] Univ Michigan, Dept Pharmaceut Sci, Ann Arbor, MI 48109 USA
[2] Purdue Univ, Ind & Mol Pharmaceut Dept, W Lafayette, IN 47907 USA
[3] Purdue Univ, Biotechnol Innovat & Regulatory Sci BIRS Ctr, Dept Agr & Biol Engn, W Lafayette, IN 47907 USA
关键词
FDA; enforcement report; stability; reference standards; degradation; levothyroxine; THYROID-HORMONES; COMPATIBILITY; PENTAHYDRATE; FORMULATION; EXCIPIENTS; STABILITY;
D O I
10.3390/ph17010042
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Levothyroxine tablets, although highly prescribed in the United States, have been one of the most frequently recalled products. Because of the importance of the medication, several efforts have been put in place by the United States Food and Drug Administration (US FDA) to control the quality of levothyroxine tablets available to patients using the drug. The choice of excipients used in the formulation has been shown to impact the hygroscopicity and microenvironment, and ultimately the stability of the levothyroxine tablets formulations. Based on information generated from the US FDA Enforcement Report database, one of the main reasons for recalls is the low potency of different batches of the product. The yearly product recall trends for levothyroxine formulations were determined using the FDA Enforcement Report database. Three brands of levothyroxine tablets were selected with excipient lists similar to those products that have been historically recalled. The samples were placed at ambient (similar to 23 degrees C), accelerated stability (40 degrees C/75% RH), and stress (50 degrees C/75% RH) conditions for up to 6 months. Sample potencies were determined at 0, 1.5, 3, and 6 months using the methods for assay and impurities in the United States Pharmacopeia (USP) monograph for levothyroxine tablets. Additional sample monitoring was conducted by overlaying the initial powder X-ray diffractograms (PXRD) of the samples from 0 months with the patterns generated thereafter. There has been a decline in the number of levothyroxine tablets recalled over the years. The highest numbers of recalls were recorded in the years 2013 [33] and 2020 [23]; no recalls occurred in the years 2019 and 2022. All of the brands evaluated met the USP 95.0-105.0% assay requirements at 1.5 months under accelerated conditions; only one of the brands complied at 3 months. Under ambient conditions, two brands were stable at 6 months, with borderline assay results. For stability, levothyroxine was found in microgram quantities in the formulations and PXRD could not detect changes at these low levels. However, we found some distinguishing data for samples under stress conditions.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] X-Ray Diffraction under Extreme Conditions at the Advanced Light Source
    Stan, Camelia, V
    Beavers, Christine M.
    Kunz, Martin
    Tamura, Nobumichi
    QUANTUM BEAM SCIENCE, 2018, 2 (01)
  • [42] X-ray diffraction imaging of fully packaged n-p-n transistors under accelerated ageing conditions
    Tanner, Brian K.
    Danilewsky, Andreas
    McNally, Patrick J.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2022, 55 (05) : 1139 - 1146
  • [43] Flux monitoring by x-ray diffracting crystals under ambient air conditions
    Stoupin, Stanislav
    Baryshev, Sergey V.
    Antipov, Sergey P.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX, 2014, 9207
  • [44] Synchrotron beamline optics for X-ray powder diffraction under high-pressure conditions at the Siam Photon Laboratory
    Saengsuwan, V.
    Klysubun, W.
    Bovornratanaraks, T.
    Rugmai, S.
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 2009, : 189 - 194
  • [45] X-ray powder diffraction of NaCl under pressure: Nanocrystals induce anomalous strains
    Weber, HJ
    Keller, HL
    Lathe, C
    Popa-Varga, C
    JOURNAL OF APPLIED PHYSICS, 2005, 98 (03)
  • [46] The location of pyridine in sodium-silver-Y zeolite by powder synchrotron X-ray diffraction
    Ostbo, NP
    Goyal, R
    Jobic, H
    Fitch, AN
    MICROPOROUS AND MESOPOROUS MATERIALS, 1999, 30 (2-3) : 255 - 265
  • [47] Powder x-ray diffraction of BaFe2As2 under hydrostatic pressure
    Eguchi, N.
    Kodama, M.
    Ishikawa, F.
    Nakayama, A.
    Ohmura, A.
    Yamada, Yuh
    Nakano, S.
    26TH INTERNATIONAL CONFERENCE ON LOW TEMPERATURE PHYSICS (LT26), PTS 1-5, 2012, 400
  • [48] REACTIONS OF MAGNESIUM CARBONATES BY DIRECT X-RAY DIFFRACTION UNDER HYDROTHERMAL CONDITIONS
    IWAI, SI
    SOTOME, Y
    AOKI, H
    MORIKAWA, H
    AMERICAN MINERALOGIST, 1971, 56 (3-4) : 628 - &
  • [49] INSTRUMENTATION FOR X-RAY FIBRE DIFFRACTION UNDER INDUSTRIAL PROCESSING CONDITIONS.
    Mahendrasingam, Arumugam
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C14 - C14
  • [50] X-RAY DIFFRACTION UNDER CONDITIONS OF SPATIALLY-INHOMOGENEOUS DYNAMIC PROBLEM
    SLOBODETSKII, IS
    CHUKHOVSKII, FN
    INDENBOM, VL
    JETP LETTERS-USSR, 1968, 8 (02): : 55 - +