Levothyroxine tablets, although highly prescribed in the United States, have been one of the most frequently recalled products. Because of the importance of the medication, several efforts have been put in place by the United States Food and Drug Administration (US FDA) to control the quality of levothyroxine tablets available to patients using the drug. The choice of excipients used in the formulation has been shown to impact the hygroscopicity and microenvironment, and ultimately the stability of the levothyroxine tablets formulations. Based on information generated from the US FDA Enforcement Report database, one of the main reasons for recalls is the low potency of different batches of the product. The yearly product recall trends for levothyroxine formulations were determined using the FDA Enforcement Report database. Three brands of levothyroxine tablets were selected with excipient lists similar to those products that have been historically recalled. The samples were placed at ambient (similar to 23 degrees C), accelerated stability (40 degrees C/75% RH), and stress (50 degrees C/75% RH) conditions for up to 6 months. Sample potencies were determined at 0, 1.5, 3, and 6 months using the methods for assay and impurities in the United States Pharmacopeia (USP) monograph for levothyroxine tablets. Additional sample monitoring was conducted by overlaying the initial powder X-ray diffractograms (PXRD) of the samples from 0 months with the patterns generated thereafter. There has been a decline in the number of levothyroxine tablets recalled over the years. The highest numbers of recalls were recorded in the years 2013 [33] and 2020 [23]; no recalls occurred in the years 2019 and 2022. All of the brands evaluated met the USP 95.0-105.0% assay requirements at 1.5 months under accelerated conditions; only one of the brands complied at 3 months. Under ambient conditions, two brands were stable at 6 months, with borderline assay results. For stability, levothyroxine was found in microgram quantities in the formulations and PXRD could not detect changes at these low levels. However, we found some distinguishing data for samples under stress conditions.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Powder X-ray diffraction under extreme conditions of pressure and temperature
    Fiquet, G
    Andrault, D
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 81 - 86
  • [2] The influence of reflection and transmission geometries on powder X-ray diffraction (pXRD) patterns of an API
    Barnes, C. A.
    Busby, D. J.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2005, 57 : S82 - S82
  • [3] Powder X-ray diffraction conditions for screening curcumin in turmeric powder
    R. Paranthaman
    J. A. Moses
    C. Anandharamakrishnan
    Journal of Food Measurement and Characterization, 2022, 16 : 1105 - 1113
  • [4] Powder X-ray diffraction conditions for screening curcumin in turmeric powder
    Paranthaman, R.
    Moses, J. A.
    Anandharamakrishnan, C.
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2022, 16 (02) : 1105 - 1113
  • [5] X-ray diffraction studies of millerite NiS under non-ambient conditions
    Sowa, H
    Ahsbahs, H
    Schmitz, W
    PHYSICS AND CHEMISTRY OF MINERALS, 2004, 31 (05) : 321 - 327
  • [6] X-ray diffraction studies of millerite NiS under non-ambient conditions
    H. Sowa
    H. Ahsbahs
    W. Schmitz
    Physics and Chemistry of Minerals, 2004, 31 : 321 - 327
  • [7] RietveldToTensor: Program for Processing Powder X-Ray Diffraction Data under Variable Conditions
    Bubnova, R. S.
    Firsova, V. A.
    Volkov, S. N.
    Filatov, S. K.
    GLASS PHYSICS AND CHEMISTRY, 2018, 44 (01) : 33 - 40
  • [8] RietveldToTensor: Program for Processing Powder X-Ray Diffraction Data under Variable Conditions
    R. S. Bubnova
    V. A. Firsova
    S. N. Volkov
    S. K. Filatov
    Glass Physics and Chemistry, 2018, 44 : 33 - 40
  • [9] An investigation into the use of X-ray powder diffraction (XRPD) for the analysis of intact tablets
    Barnes, C. A.
    Busby, D. J.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 : A4 - A5
  • [10] Neutron and X-ray diffraction studies of piezoelectric materials under non-ambient conditions
    Haines, J
    Cambon, O
    Rouquette, J
    Bornand, V
    Papet, P
    Léger, JM
    Hull, S
    EUROPEAN POWDER DIFFRACTION EPDIC 8, 2004, 443-4 : 277 - 282