Axillary mechanical circulatory support improves renal function prior to heart transplantation in patients with chronic kidney disease

被引:2
|
作者
Jang, Ji-Min [1 ]
Jarmi, Tambi [2 ]
Sareyyupoglu, Basar
Nativi, Jose [1 ]
Patel, Parag C. [1 ]
Leoni, Juan C. [1 ]
Landolfo, Kevin [3 ]
Pham, Si [3 ]
Yip, Daniel S. [1 ]
Goswami, Rohan M. [1 ]
机构
[1] Mayo Clin Florida, Div Heart Failure & Transplant, 4500 San Pablo Rd, Jacksonville, FL 32246 USA
[2] Mayo Clin Florida, Div Transplant Nephrol, Jacksonville, FL USA
[3] Mayo Clin Florida, Dept Cardiothorac Surg, Jacksonville, FL USA
关键词
OUTCOMES; RECIPIENTS; RISK;
D O I
10.1038/s41598-023-46901-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Impaired kidney function is often associated with acute decompensation of chronic heart failure and portends a poor prognosis. Unfortunately, current data have demonstrated worse survival in patients with acute kidney injury than in patients with chronic kidney disease during durable LVAD placement as bridge therapy. Furthermore, end-stage heart failure patients undergoing combined heart-kidney transplantation have poorer short- and long-term survival than heart transplants alone. We evaluated the kidney function recovery in our heart failure population awaiting heart transplantation at our institution, supported by temporary Mechanical Circulatory Support (tMCS) with Impella 5.5. The protocol (#22004000) was approved by the Mayo Clinic institutional review board, after which we performed a retrospective review of all patients with acute on chronic heart failure and kidney disease in patients considered for only heart and kidney combined organ transplant and supported by tMCS between January 2020 and February 2021. Hemodynamic and kidney function trends were recorded and analyzed before and after tMCS placement and transplantation. After placement of tMCS, we observed a trend towards improvement in creatinine, Fick cardiac index, mixed venous saturation, and glomerular filtration rate (GFR), which persisted through transplantation and discharge. The average duration of support with tMCS was 16.5 days before organ transplantation. The median pre-tMCS creatinine was 2.1 mg/dL (IQR 1.75-2.3). Median hematocrit at the time of tMCS placement was 32% (IQR 32-34), and the median estimated glomerular filtration rate was 34 mL/min/BSA (34-40). The median GFR improved to 44 mL/min/BSA (IQR 45-51), and serum creatinine improved to 1.5 mg/dL (1.5-1.8) after tMCS. Median discharge creatinine was 1.1 mg/dL (1.19-1.25) with a GFR of 72 (65-74). None of these six patients supported with tMCS required renal replacement therapy after heart transplantation. Early adoption of Impella 5.5 in this patient population resulted in renal recovery without needing renal replacement therapies or dual organ transplantation and should be further evaluated.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Mechanical Circulatory Support Improves Diabetic Control in Patients With Advanced Heart Failure
    Sundararajan, S. K.
    Krikorian, A.
    Sayer, G.
    Bhat, G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S87 - S88
  • [32] MECHANICAL CIRCULATORY SUPPORT IMPROVES DIABETIC CONTROL IN PATIENTS WITH ADVANCED HEART FAILURE
    Krikorian, A.
    Bhat, G.
    Sundararajan, S.
    Sayer, G.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (04) : 726 - 726
  • [33] MECHANICAL CIRCULATORY SUPPORT PRIOR TO COMBINED HEART AND KIDNEY TRANSPLANT A LONG BUT WORTHY FIGHT TO FIGHT
    Restrepo, Valentina Jaramillo
    Hess, Nicholas
    Horn, Edward
    Kaczorowski, David
    Hickey, Gavin W.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 3986 - 3986
  • [34] Advancements in mechanical circulatory support for patients in acute and chronic heart failure
    Csepe, Thomas A.
    Kilic, Ahmet
    JOURNAL OF THORACIC DISEASE, 2017, 9 (10) : 4070 - 4083
  • [35] Patterns of Mechanical Circulatory Support By Heart Failure Etiology in Patients Listed for Heart Transplantation
    Al-Kindi, S.
    Kumar, S.
    Ige, M.
    Ginwalla, M.
    ElAmm, C.
    Deo, S.
    Park, S. J.
    Oliveira, G. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S58 - S58
  • [36] Mechanical Circulatory Support Prior to Heart Transplantation Predicts Early Post-Operative Stroke
    Bickel, Trenton J.
    Gunasekaran, Prasad
    Parashara, Deepak K.
    Alpert, Martin A.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2021, 362 (01): : 34 - 38
  • [37] Significant benefits after renal transplantation in patients with chronic heart failure and chronic kidney disease
    Kute, Vivek B.
    Vanikar, Aruna V.
    Patel, Himanshu V.
    Gumber, Manoj R.
    Shah, Pankaj R.
    Engineer, Divyesh P.
    Balwani, Manish R.
    Gautam, Rajesh Singh
    Modi, Pranjal R.
    Shah, Veena R.
    Trivedi, Hargovind L.
    RENAL FAILURE, 2014, 36 (06) : 854 - 858
  • [38] Incidence and Outcomes of Acute Circulatory Support Prior to Heart Transplantation
    Ouyang, D.
    Gulati, G.
    Ha, R.
    Banerjee, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S138 - S138
  • [39] Mechanical circulatory support: not only a bridge to heart transplantation
    Sobieszczanska-Malek, Malgorzata
    Zielinski, Tomasz
    Korewicki, Jerzy
    KARDIOLOGIA POLSKA, 2012, 70 (11) : 1182 - 1186
  • [40] Mechanical circulatory support after orthotopic heart transplantation
    Tenderich, G
    Koerner, MM
    Stuettgen, B
    Minami, K
    El-Banayosy, A
    Arusoglu, L
    Mirow, N
    Wlost, S
    Gromzik, H
    Kleesiek, K
    Meyer, H
    Koerfer, R
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (07): : 414 - 416