Phase Shift APOD and POD Control Technique in Multi-Level Inverters to Mitigate Total Harmonic Distortion

被引:3
|
作者
Bano, Kalsoom [1 ]
Abbas, Ghulam [1 ]
Hatatah, Mohammed [2 ]
Touti, Ezzeddine [3 ]
Emara, Ahmed [4 ,5 ]
Mercorelli, Paolo [6 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China
[2] Al Baha Univ, Dept Elect Engn, Al Baha 65779, Saudi Arabia
[3] Northern Border Univ, Coll Engn, Dept Elect Engn, Ar Ar 73213, Saudi Arabia
[4] Univ Business & Technol, Dept Elect Engn, Jeddah 21432, Saudi Arabia
[5] Alexandria Univ, Fac Engn, Dept Engn Math & Phys, Alexandria 21544, Egypt
[6] Leuphana Univ Luneburg, Inst Prod Technol & Syst IPTS, D-21335 Luneburg, Germany
关键词
level-shifted POD; level-shifted APOD; THD; DSP control;
D O I
10.3390/math12050656
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
Multi-level inverters are widely employed to generate new energy because of their huge capacity and benefits in sound control performance. One of the critical areas of study for multi-level inverters is control strategy research. In this study, the control strategy for a multi-level inverter-which is frequently employed in HVDC and FACTS systems-is designed. An asymmetrical D.C. voltage source is supplied to create the appropriate output voltage waveform with fewer total harmonic distortions (THDs) at the output voltage and current waveforms. In this work, the pulse width modulation techniques of POD (phase opposition disposition) and APOD (alternative phase opposition disposition) MC PWM are applied to a multi-level inverter to generate the seven-level output voltage waveform. This study presents an enhanced variable carrier frequency APOD control approach that can successfully lower the overall harmonic distortion rate. The design and completion of the phase-shifting POD and APOD control strategies are followed by an analysis and comparison of the THD situation under various switching frequencies and a simulation and verification of the control strategy using MATLAB simulation. The TI DSP-based control approach has been programmed. The APOD technique increases the output voltage's THD to 18.27%, while the output current waveform's THD is reduced to 15.67% by utilizing the APOD PWM technique. Using the POD PWM approach increases the total harmonic distortion (THD) of the voltage waveform by 18.06% and the output current waveform's THD by 15.45%.
引用
收藏
页数:26
相关论文
共 50 条
  • [11] A New Reliability Evaluation Technique for Multi-Level Inverters
    Kiaee, S. M. Sadat
    Namadmalan, A.
    Moghani, J. Shokrollahi
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 361 - 366
  • [12] Reduction in Total Harmonic Distortion by Implementing Multi-Level Inverter Technology in Grid Integrated DFIG
    Shrivastava, Sarika
    Tripathi, Anurag
    Venna, K. S.
    2015 COMMUNICATION, CONTROL AND INTELLIGENT SYSTEMS (CCIS), 2015, : 491 - 495
  • [13] Total Harmonic Distortion Oriented Finite Control Set Model Predictive Control for Single-Phase Inverters
    Li, Po
    Li, Ruiyu
    Feng, Haifeng
    ENERGIES, 2018, 11 (12)
  • [14] Harmonic Optimization in Multi-Level Inverters using Harmony Search Algorithm
    Majidi, B.
    Baghaee, H. R.
    Gharehpetian, G. B.
    Milimonfared, J.
    Mirsalim, M.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 646 - 650
  • [15] Application of memetic algorithm for selective harmonic elimination in multi-level inverters
    Kumle, Alireza Niknam
    Fathi, Seyed Hamid
    Jabbarvaziri, Faramarz
    Jamshidi, Mehdi
    Yazdi, Seyed Saeed Heidari
    IET POWER ELECTRONICS, 2015, 8 (09) : 1733 - 1739
  • [16] Harmonic analysis and output filter design of NPC multi-level inverters
    Kim, Soo-Hong
    Kim, Yoon-Ho
    Seo, Kang-Moon
    Bang, Sang-Seok
    Kim, Kwang-Seob
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 2862 - +
  • [17] A Novel Memetic Algorithm Approach For Selective Harmonic Elimination in Multi-Level inverters
    Kumle, Alireza Niknam
    Fathi, S. H.
    Yazdi, S. S. Heidary
    2014 5TH POWER ELECTRONICS, DRIVE SYSTEMS AND TECHNOLOGIES CONFERENCE (PEDSTC), 2014, : 205 - 210
  • [18] MULTI-LEVEL SVM FOR SIX-PHASE MULTI-LEVEL INVERTERS TO DRIVE DUAL STATOR INDUCTION MACHINE
    Bekrar, Lyas
    Bouhali, Omar
    Mohammed, Yaichi
    Rizoug, Nassim
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 40 (02): : 72 - 78
  • [19] Multi-level Phase Shift (MLPS) control enabled variable displacement gerotor/geroler
    Yuan, QingHul
    Armstrong, Brian
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINERING CONGRESS AND EXPOSITION 2007, VOL 9, PTS A-C: MECHANICAL SYSTEMS AND CONTROL, 2008, : 527 - 536
  • [20] Harmonic distortion reduction in multi-level PWM modulators for audio power amplifiers
    Antunes, VME
    Pires, VF
    Silva, JF
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 852 - 857