Seven-Year Operation of 25 T Cryogen-Free Superconducting Magnet as a User Magnet at HFLSM, IMR, Tohoku University

被引:2
|
作者
Takahashi, K. [1 ]
Okada, T. [1 ]
Tsuchiya, Y. [1 ]
Awaji, S. [1 ]
Takewa, H. [2 ]
Hanai, S. [2 ]
Ioka, S. [2 ]
机构
[1] Tohoku Univ, Inst Mat Res, High Field Lab Superconducting Mat, Sendai, 9808577, Japan
[2] Toshiba Energy Syst & Solut Corp, Yokohama 2300045, Japan
关键词
Bi2223; coil; cryogen-free superconducting magnet; high magnetic field; quench;
D O I
10.1109/TASC.2024.3350566
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 25 T cryogen-free superconducting magnet (25 T-CSM) was installed at the High Field Laboratory for Superconducting Materials, Institute for Materials Research, Tohoku University in 2015. The 25T-CSM consists of low-temperature superconducting (LTS) outsert coils and a high-temperature superconducting (HTS) coil; high strength CuNb/Nb3Sn and NbTi Rutherford cables, and Bi2Sr2Ca2Cu3Oy (Bi2223) tape were adopted for the LTS and HTS coil, respectively. The Bi2223 coil was a stack of impregnated double pancake (DP) coils. The first Bi2223 coil generated 10.6 T in a background field of 14.0 T by the LTS coils in 2015. Because of the coil stiffness insufficiency, it had an electrical instability. The new Bi2223 coil, made by improving the stiffness of DPs, successfully generated 11.1 T (25.1 T in total) in 2020. Both Bi2223 coils experienced accidental quenches during the operations as a user magnet. However, the magnet's quench detection and protection system protected the coils from the damage including the LTS coils. The 25T-CSM has been operated as a multipurpose user magnet for more than 1100 days in seven years, meaning that almost 100% of the available days were utilized for user experiments.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [31] Cryogen-free open superconducting magnet for interventional MRI applications
    General Electric Corp Research &, Development, Schenectady, United States
    IEEE Trans Appl Supercond, 2 pt 1 (163-168):
  • [32] A CRYOGEN-FREE SUPERCONDUCTING MAGNET DESIGN FOR MAGLEV VEHICLE APPLICATIONS
    Vermilyea, Mark E.
    Minas, Constantinos
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) : 444 - 447
  • [33] Test of peltier current lead for cryogen-free superconducting magnet
    Hamabe, M.
    Sasaki, A.
    Kasukabe, T.
    Oue, M.
    Nakamura, K.
    Yamaguchi, S.
    Ninomiya, A.
    Okumura, H.
    Kawamura, K.
    Aoki, I.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 465 - 468
  • [34] Development of 9.5 T NbTi cryogen-free magnet
    Shen, WJ
    Coffey, M
    McGhee, W
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2619 - 2622
  • [35] The 5.8 T Cryogen-Free Gyrotron Superconducting Magnet System on HL-2A
    Xia Donghui
    Huang Mei
    Zhou Jun
    Bai Xingyu
    Zheng Tieliu
    Rao Jun
    Zhuang Ge
    PLASMA SCIENCE & TECHNOLOGY, 2014, 16 (04) : 410 - 414
  • [36] Repairing and Upgrading of the HTS insert in the 18T Cryogen-free Superconducting Magnet
    Awaji, S.
    Oguro, H.
    Watanabe, K.
    Hanai, S.
    Ioka, S.
    Miyazaki, H.
    Daibo, M.
    Iijima, Y.
    Saito, T.
    Itoh, M.
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 732 - 738
  • [37] Tunable Second Harmonic Gyrotron Based on a 12 T Superconducting, Cryogen-Free Magnet
    Fliflet, Arne W.
    Gold, Steven H.
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [38] The 5.8 T Cryogen-Free Gyrotron Superconducting Magnet System on HL-2A
    夏冬辉
    黄梅
    周俊
    白兴宇
    郑铁流
    饶军
    庄革
    Plasma Science and Technology, 2014, 16 (04) : 410 - 414
  • [39] Basic Design of REBCO Insert Coil of 33 T Cryogen-Free Superconducting Magnet
    Uto, T.
    Tosaka, T.
    Shitaka, T.
    Nezuka, H.
    Hanai, S.
    Takewa, H.
    Inagaki, J.
    Ioka, S.
    Badel, A.
    Takahashi, K.
    Zampa, A.
    Okada, T.
    Tsuchiya, Y.
    Awaji, S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2025, 35 (05)
  • [40] Design, Fabrication and Measurement of a 3 T Cryogen-Free Animal MRI Superconducting Magnet
    Wang, Yaohui
    Liu, Hui
    Chen, Shunzhong
    Wang, Weimin
    Liu, Feng
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 4