CFD simulation of osmotic membrane distillation using hollow fiber membrane contactor: Operating conditions and concentration polarization effects

被引:5
|
作者
Ullah, Syed Zia [1 ,6 ]
Muhammad, Amir [2 ]
Sohaib, Qazi [3 ]
Younas, Mohammad [1 ,4 ]
Yuan, Zhi-Hua [4 ]
Rezakazemi, Mashallah [5 ]
机构
[1] Univ Engn & Technol, Dept Chem Engn, POB 814,Univ Campus, Peshawar 25120, Pakistan
[2] Pak Austria Fachhsch Inst Appl Sci & Technol PAF I, Dept Chem & Energy Engn, Haripur, Pakistan
[3] Univ Montpellier, European Membranes Inst, Montpellier, France
[4] Chinese Acad Sci, Inst Urban Environm, CAS Key Lab Urban Pollutant Convers, Xiamen 361021, Peoples R China
[5] Shahrood Univ Technol, Fac Chem & Mat Engn, 9WVR 757, Shahrood, Iran
[6] Univ Groningen, Dept Chem Engn, Green Chem React Engn, NL-9747 AG Groningen, Netherlands
来源
关键词
Osmotic membrane distillation; Hollow fiber membrane contactor; Computational fluid dynamics; Inorganic salt recovery; Concentration polarization; WASTE-WATER; CRYSTALLIZATION; RECOVERY;
D O I
10.1016/j.cherd.2023.08.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Inorganic salts, when present in high concentrations, can disrupt the osmotic balance of aquatic organisms, leading to physiological and ecological harm. Osmotic membrane distillation (OMD) is an emerging technique for recovering inorganic salts from waste-water. The process involves the transfer of water vapor from a feed solution (FS) to a permeate stream due to the difference in vapor pressure across a hydrophobic membrane. It thus results in a concentrated solution at the feed outlet and purified water at the permeate side. OMD is preferred due to its straightforward scale-up and low energy requirements. In this research, a steady state 2-D axisymmetric computational fluid dynamics (CFD) model is developed to study the recovery of sodium carbonate (Na2CO3) from aqueous feed solution through OMD in a hollow fiber membrane contactor (HFMC). Aqueous sodium chloride (NaCl) solution was taken as an osmotic solution (OS). The numerical convection-diffusion mass, momentum transport, and Happel equations were scripted in COMSOL MultiphysicsTM version 6.0 software. The model computed the water transport from FS to OS. Computed water flux well matched with the literature based experimental results. Simulations were carried out to investigate the parametric effects, including Reynold's number, FS and OS concentration and the module geometrical parameters to establish an optimized operating conditions and module geometry and to achieve the desired FS concentration. Results showed that a 2-fold rise in OS concentration increased the transmembrane water flux 4-fold. However, the flow rates of both FS and OS did not significantly affect the flux. On the other hand, concentration polarization (CP) showed dependence on the FS concentration, tortuosity, and Reynolds number. A membrane tortuosity of 1.6, feed concentration of 75 g L-1, OS concentration of 300 g L-1, and a FS Reynolds number in the turbulent flow range can result in higher transmem-brane flux and lower chances of CP development. (c) 2023 Institution of Chemical Engineers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:984 / 996
页数:13
相关论文
共 50 条
  • [21] Simulation of mass transfer in hollow fiber used for concentration of juices by osmotic distillation
    Zambra, Carlos
    HELIYON, 2019, 5 (04)
  • [22] CFD Simulation of Hydrogen Separation in Pd Hollow Fiber Membrane
    Mansourpour, Zahra
    Ziaei-Halimejani, Hooman
    Sadeghnejad, Seyed Morteza
    Boskabadi, Mohammadreza
    CHEMICAL PRODUCT AND PROCESS MODELING, 2016, 11 (01): : 83 - 88
  • [23] Simulation of Carbon Dioxide Absorption in a Hollow Fiber Membrane Contactor Under Non-Isothermal Conditions
    Jin, Youkang
    Wang, Lei
    Bi, Jinpeng
    Zhao, Wei
    Zhang, Hui
    Lv, Yuexia
    Chen, Xi
    MEMBRANES, 2025, 15 (03)
  • [24] Concentration polarization model for hollow-fiber membrane ultrafiltration
    Yeh, H.-M.
    Cheng, T.-W.
    1600, (29):
  • [25] Integrated CFD simulation of concentration polarization in narrow membrane channel
    Ahmad, AL
    Lau, KK
    Abu Bakar, MZ
    Abd Shukor, SR
    COMPUTERS & CHEMICAL ENGINEERING, 2005, 29 (10) : 2087 - 2095
  • [26] Simulation of CO2 absorption into aqueous DEA using a hollow fiber membrane contactor: Evaluation of contactor performance
    Delgado, José A.
    Uguina, María A.
    Sotelo, José L.
    Águeda, Vicente I.
    Sanz, Abel
    Chemical Engineering Journal, 2009, 152 (2-3): : 396 - 405
  • [27] CONCENTRATION POLARIZATION MODEL FOR HOLLOW-FIBER MEMBRANE ULTRAFILTRATION
    YEH, HM
    CHENG, TW
    SEPARATION SCIENCE AND TECHNOLOGY, 1994, 29 (04) : 497 - 512
  • [28] Simulation of CO2 absorption into aqueous DEA using a hollow fiber membrane contactor: Evaluation of contactor performance
    Delgado, Jose A.
    Uguina, Maria A.
    Sotelo, Jose L.
    Agueda, Vicente I.
    Sanz, Abel
    CHEMICAL ENGINEERING JOURNAL, 2009, 152 (2-3) : 396 - 405
  • [29] Concentration of skim milk using a hybrid system of osmotic distillation and membrane distillation
    Gul, Kubra
    Hasanoglu, Ayca
    DESALINATION AND WATER TREATMENT, 2019, 149 : 11 - 22
  • [30] Study on vacuum membrane distillation (VMD) using FEP hollow fiber membrane
    Chen, Kaikai
    Xiao, Changfa
    Huang, Qinglin
    Liu, Huan
    Liu, Hailiang
    Wu, Yanjie
    Liu, Zhen
    DESALINATION, 2015, 375 : 24 - 32