Determination of thallium in vegetative plant leaves near industrial areas by high-resolution continuum source electrothermal atomic absorption spectrometry after salt induced cloud point extraction

被引:8
|
作者
Meeravali, Noorbasha N. [1 ]
Madhavi, K. [1 ]
Sahayam, A. C. [1 ]
机构
[1] Bhabha Atom Res Ctr BARC, Natl Ctr Composit Characterizat Mat NCCCM, ECIL Post, Hyderabad 500062, India
关键词
Thallium; Cloud point extraction; Salting out agent; Microwave digestion; Triton X-100; HR-CS-ETAAS; NON-SPECTRAL INTERFERENCES; WATER SAMPLES; ENVIRONMENTAL-SAMPLES; MASS-SPECTROMETRY; BACK-EXTRACTION; ICP-OES; PRECONCENTRATION; MICROWAVE; SEDIMENT; METALS;
D O I
10.1016/j.sab.2022.106613
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A rapid analytical procedure is described for the separation and pre-concentration of ultra trace level thallium from the microwave assisted nitric acid digests of plant samples and determination using high resolution con-tinuum source electrothermal atomic absorption spectrometry (HR-CS-ETAAS). The method is based on the extraction of ionic thallium spices formed in-situ in the nitric acid digests of plant leaves with Triton X-100 micelles, in presence of HCl and NaCl. The hydrophobic solubilising sites of Triton X-100 micelles are used for the pre-concentration of hydrophobic species of thallium from bulk aqueous phase into a small surfactant rich phase. The main parameters affecting the extraction process are evaluated and optimized. A rapid temperature program completed within 15 s is used for the determination of thallium using a permanent Zr-Ir modifier. Under the optimized conditions, the pre-concentration factor and limit of detection are 25 and 0.05 ng mL-1, respectively. A characteristic mass of 12 pg is obtained on measuring the integrated absorbance with central pixel & PLUSMN;1. The recoveries are in the range of 95-99% at 1 ng mL-1 with 2-3% relative standard deviation. The accuracy of the method is verified by analyzing certified reference materials such as BCR 060 aquatic plant and NIST 1572 citrus leaves. The obtained values are in good agreement with the certified values. The procedure is also applied to real samples such as spinach, cabbage, aquatic, and tobacco plant leaves collected near thermal power plants and industrial areas.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Determination of Gold by High-Resolution Continuum Source Atomic Absorption Spectrometry with Chemical Vapor Generation
    Krawczyk, Magdalena
    Matusiewicz, Henryk
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (05) : 749 - 757
  • [22] Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis
    Silva, Arlene S.
    Brandao, Geovani C.
    Matos, Geraldo D.
    Ferreira, Sergio L. C.
    TALANTA, 2015, 144 : 39 - 43
  • [23] Determination of Ultratrace Amounts of Copper(Ⅱ) in Water Samples by Electrothermal Atomic Absorption Spectrometry After Cloud Point Extraction
    CHEN Jian-guo1
    2. Ningbo Entry-Exit Inspection and Quarantine Bureau
    ChemicalResearchinChineseUniversities, 2007, (02) : 143 - 147
  • [24] Determination of macro- and micronutrients in plant leaves by high-resolution continuum source flame atomic absorption spectrometry combining instrumental and sample preparation strategies
    Oliveira, Silvana R.
    Gomes Neto, Jose A.
    Nobrega, Joaquim A.
    Jones, Bradley T.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (04) : 316 - 320
  • [25] Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    Bernhard Welz
    Maria Goreti R. Vale
    Daniel L. G. Borges
    Uwe Heitmann
    Analytical and Bioanalytical Chemistry, 2007, 389 : 2085 - 2095
  • [26] Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    Welz, B.
    Borges, D. L. G.
    Welz, B.
    Vale, M. G. R.
    Heitmann, U.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (7-8) : 2085 - 2095
  • [27] Determination of Sulfur in Grape and Apricot Samples Using High-resolution Continuum Source Electrothermal Molecular Absorption Spectrometry
    Yasin Arslan
    J. A. C. Broekaert
    İbrahim Kula
    Analytical Sciences, 2018, 34 : 831 - 836
  • [28] Determination of Sulfur in Grape and Apricot Samples Using High-resolution Continuum Source Electrothermal Molecular Absorption Spectrometry
    Arslan, Yasin
    Broekaert, J. A. C.
    Kula, Ibrahim
    ANALYTICAL SCIENCES, 2018, 34 (07) : 831 - 836
  • [29] High-resolution continuum source electrothermal atomic absorption spectrometry: Linearization of the calibration curves within a broad concentration range
    Katskov, Dmitri
    Hlongwane, Miranda
    Heitmann, Uwe
    Florek, Stefan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 14 - 23
  • [30] Simultaneous determination of Cd and Fe in grain products using direct solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    dos Santos, Lisia M. G.
    Araujo, Rennan G. O.
    Welz, Bernhard
    Jacob, Silvana Do C.
    Vale, Maria Goreti R.
    Becker-Ross, Helmut
    TALANTA, 2009, 78 (02) : 577 - 583