Determination of thallium in vegetative plant leaves near industrial areas by high-resolution continuum source electrothermal atomic absorption spectrometry after salt induced cloud point extraction

被引:8
|
作者
Meeravali, Noorbasha N. [1 ]
Madhavi, K. [1 ]
Sahayam, A. C. [1 ]
机构
[1] Bhabha Atom Res Ctr BARC, Natl Ctr Composit Characterizat Mat NCCCM, ECIL Post, Hyderabad 500062, India
关键词
Thallium; Cloud point extraction; Salting out agent; Microwave digestion; Triton X-100; HR-CS-ETAAS; NON-SPECTRAL INTERFERENCES; WATER SAMPLES; ENVIRONMENTAL-SAMPLES; MASS-SPECTROMETRY; BACK-EXTRACTION; ICP-OES; PRECONCENTRATION; MICROWAVE; SEDIMENT; METALS;
D O I
10.1016/j.sab.2022.106613
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A rapid analytical procedure is described for the separation and pre-concentration of ultra trace level thallium from the microwave assisted nitric acid digests of plant samples and determination using high resolution con-tinuum source electrothermal atomic absorption spectrometry (HR-CS-ETAAS). The method is based on the extraction of ionic thallium spices formed in-situ in the nitric acid digests of plant leaves with Triton X-100 micelles, in presence of HCl and NaCl. The hydrophobic solubilising sites of Triton X-100 micelles are used for the pre-concentration of hydrophobic species of thallium from bulk aqueous phase into a small surfactant rich phase. The main parameters affecting the extraction process are evaluated and optimized. A rapid temperature program completed within 15 s is used for the determination of thallium using a permanent Zr-Ir modifier. Under the optimized conditions, the pre-concentration factor and limit of detection are 25 and 0.05 ng mL-1, respectively. A characteristic mass of 12 pg is obtained on measuring the integrated absorbance with central pixel & PLUSMN;1. The recoveries are in the range of 95-99% at 1 ng mL-1 with 2-3% relative standard deviation. The accuracy of the method is verified by analyzing certified reference materials such as BCR 060 aquatic plant and NIST 1572 citrus leaves. The obtained values are in good agreement with the certified values. The procedure is also applied to real samples such as spinach, cabbage, aquatic, and tobacco plant leaves collected near thermal power plants and industrial areas.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    T. N. Shtin
    V. B. Gurvich
    O. E. Galasheva
    I. G. Shelomentsev
    L. K. Neudachina
    S. A. Shtin
    Inorganic Materials, 2023, 59 : 1387 - 1395
  • [2] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Shtin, T. N.
    Gurvich, V. B.
    Galasheva, O. E.
    Shelomentsev, I. G.
    Neudachina, L. K.
    Shtin, S. A.
    INORGANIC MATERIALS, 2023, 59 (14) : 1387 - 1395
  • [3] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    M. Yu. Burylin
    E. S. Kopeyko
    E. S. Kostyuchenko
    Journal of Analytical Chemistry, 2024, 79 : 310 - 317
  • [4] Determination of Cr and Ni in Seawater by High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Burylin, M. Yu.
    Kopeyko, E. S.
    Kostyuchenko, E. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (03) : 310 - 317
  • [5] High-resolution continuum source electrothermal absorption spectrometry of AlBr and CaBr for the determination of bromine
    Huang, Mao Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Heitmann, Uwe
    Okruss, Michael
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (05) : 566 - 570
  • [6] Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Lepri, Fabio G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (05) : 429 - 434
  • [7] Investigation of interferences in the determination of thallium in marine sediment reference materials using high-resolution continuum-source atomic absorption spectrometry and electrothermal atomization
    Welz, B
    Vale, MGR
    Silva, MM
    Becker-Ross, H
    Huang, MD
    Florek, S
    Heitmann, U
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (06) : 1043 - 1055
  • [8] Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    Husakova, Lenka
    Sidova, Tereza
    Ibrahimova, Lucie
    Svizelova, Monika
    Mikysek, Tomas
    ANALYTICAL METHODS, 2019, 11 (09) : 1254 - 1263
  • [9] High-resolution continuum source electrothermal atomic absorption spectrometry - An analytical and diagnostic tool for trace analysis
    Welz, Bernhard
    Borges, Daniel L. G.
    Lepri, Fabio G.
    Vale, Maria Goreti R.
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 873 - 883
  • [10] Determination of Trace Lead in Environmental Water by Cloud Point Extraction-High Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Sun Bo-si
    Ren Ting
    Zhao Li-jiao
    Zhong Ru-gang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (10) : 2847 - 2852