A multi-stage approach for high-precision measurement of cervical curvature in X-ray images

被引:1
|
作者
Zhong, Yuan [1 ]
Huang, Ya-Nan [1 ]
Zhou, Jing [1 ]
Li, Ping [1 ]
Yang, Yi [2 ]
Ma, Li-Tai [2 ]
Zhang, Xiang [2 ]
机构
[1] Southwest Petr Univ, Sch Comp Sci, Chengdu, Peoples R China
[2] Sichuan Univ, West China Hosp, Orthoped Res Inst, Dept Orthoped, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Cervical Cobb angle; Feature fusion; Multi-stage; Image segmentation; X-ray images; COBB ANGLE MEASUREMENT; NETWORK;
D O I
10.1016/j.bspc.2023.105835
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As people's lifestyles change, cervical spondylosis affects people more often. Early diagnosis is thus crucial in the management of cervical spondylosis. Cervical curvature abnormalities may serve as an objective diagnostic standard in radiographs, commonly assessed by the Cobb angle measurement in clinical practice. The method involves the clinician marking four corners of each vertebra and then drawing lines to calculate the Cobb angle using specific rules. The whole process takes a long time and mainly relies on subjective experience. In this paper, we propose an automatic multi-stage method for measuring cervical spine Cobb angle, which is referred to as MSM-CSCA that can perform the precise measurement of cervical curvature. In Stage 1, the region of interest (ROI) of the cervical spine is carefully cropped automatically. In Stage 2, an improved CA-UNet is used to achieve detailed segmentation of the cervical spine region for the ROI region, which extracts features from the edges of the vertebrae and integrates them with the original ROI to highlight the vertebrae edges more distinctly. At Stage 3, the integrated features are input into a dual-branch landmark detection network, with segmentation and detection branches. Within this stage, the segmentation branch convolutional results are fed back into the detection branch after feature augmentation to provide a more accurate detection area. Finally, the accurately identified cervical landmarks from this network are used to calculate the Cobb angle. Experimental results show that the proposed method achieves SMAPE 15.05% and MAE 3.19 on X-ray images of the cervical spine, significantly better than the other benchmark methods. The proposed method can provide clinicians with an efficient, accurate, and reliable way for the estimation of cervical curvature.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] APPLICATION OF X-RAY METHOD FOR PRECISION-MEASUREMENT OF RADIUS OF CURVATURE IN MONOCRYSTALLINE PLATES
    SKUPOV, VD
    USPENSKAYA, GI
    [J]. ZAVODSKAYA LABORATORIYA, 1975, 41 (06): : 700 - 701
  • [32] A robust and accurate approach to automatic Blood Vessel detection and segmentation from Angiography X-ray images using multi-stage Random Forests
    Gupta, Vipin
    Kale, Amit
    Sundar, Hari
    [J]. MEDICAL IMAGING 2012: COMPUTER-AIDED DIAGNOSIS, 2012, 8315
  • [33] High-precision measurement of Wolter-I mandrel for X-ray microscopy by using double confocal probes
    Xue, Chunan
    Yu, Jun
    Sheng, Pengfeng
    Wang, Haojie
    Wang, Zhanshan
    Wang, Dongfang
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (13): : 2004 - 2016
  • [34] The X-ray spectrometer (XRS): A multi-stage cryogenic instrument for the Astro-E X-ray astrophysics mission
    Volz, SM
    Mitsuda, K
    Inoue, H
    Ogawara, Y
    Hirabayashi, M
    Kyoya, M
    [J]. CRYOGENICS, 1996, 36 (10) : 763 - 771
  • [35] A Lattice Implementation of High-precision IIR Filter for X-ray CT Reconstruction
    Hayashi, Kazuhisa
    Tsutsu, Hiroshi
    Morikawa, Yoshitaka
    Funabiki, Nobuo
    [J]. INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, IMECS 2012, VOL I, 2012, : 751 - 756
  • [36] High-precision X-ray polarimeter based on channel-cut crystals
    Si, Shang-Yu
    Li, Zhong-Liang
    Jia, Wen-Hong
    Xue, Lian
    Luo, Hong-Xin
    Xu, Jian-Cai
    Shen, Bai-Fei
    Zhang, Lin-Gang
    Ji, Liang-Liang
    Leng, Yu-Xin
    Tai, Ren-Zhong
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (03)
  • [37] INSTRUMENTATION FOR HIGH-PRECISION X-RAY OPTICS AT THE SYNCHROTRON RADIATION SOURCE ZELENOGRAD
    KAZIMIROV, AY
    KOVALCHUK, MV
    KREINES, AY
    MAZURENKO, SN
    SHILIN, YN
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1027 - 1030
  • [38] HIGH-PRECISION FORMING OF MASKING COATINGS OF X-RAY MASKS DIRECTLY ON THE MEMBRANES
    KORSAKOV, VS
    MAZURENKO, SN
    MISHACHOV, VI
    TRUTNEV, NF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2): : 398 - 399
  • [39] Surface evaluation of high-precision monolithic mirror for soft X-ray focusing
    Kume, T.
    Matsuzawa, Y.
    Hiraguri, K.
    Takeo, Y.
    Kimura, T.
    Kishimoto, H.
    Senba, Y.
    Ohashi, H.
    Hashizume, H.
    Mimura, H.
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XVII, 2022, 12240
  • [40] High-precision X-ray polarimeter based on channel-cut crystals
    Shang-Yu Si
    Zhong-Liang Li
    Wen-Hong Jia
    Lian Xue
    Hong-Xin Luo
    Jian-Cai Xu
    Bai-Fei Shen
    Lin-Gang Zhang
    Liang-Liang Ji
    Yu-Xin Leng
    Ren-Zhong Tai
    [J]. Nuclear Science and Techniques, 2024, 35 (03) : 32 - 41