Continuous Vertical Inside-Out Versus Traditional Vertical Inside-Out Meniscal Repair: A Biomechanical Comparison

被引:1
|
作者
de Faria, Jose Leonardo Rocha [1 ,2 ,3 ,4 ]
Santos, Arthur Paiva Grimaldi [1 ]
Pavao, Douglas Mello [1 ,3 ,4 ]
Radulski, Mariana [1 ,5 ]
Leal, Ana Carolina [1 ,6 ]
More, Ari Digiacomo Ocampo [1 ,5 ]
de Paula Mozella, Alan [1 ,3 ,4 ]
Guimaraes, Joao Antonio Matheus [1 ,6 ]
LaPrade, Robert F. [1 ,7 ,8 ]
de Mello Roesler, Carlos Rodrigo [1 ]
Salim, Rodrigo [1 ,4 ]
机构
[1] Univ Fed Santa Catarina, Biomech Engn Lab, Florianopolis, SC, Brazil
[2] Natl Inst Traumatol & Orthoped INTO, Ave Brasil 500, BR-20940070 Rio De Janeiro, RJ, Brazil
[3] Natl Inst Traumatol & Orthoped INTO, Knee Surg Ctr, Rio De Janeiro, Brazil
[4] Univ Sao Paulo, Sch Med, Ribeirao Preto, SP, Brazil
[5] Univ Fed Santa Catarina, Med Sch, Florianopolis, SC, Brazil
[6] Natl Inst Traumatol & Orthoped INTO, Res Div, Rio De Janeiro, Brazil
[7] Twin Cities Orthopaed, Edina, MN USA
[8] Univ Minnesota, Sch Med, Minneapolis, MN USA
关键词
biomechanics; inside-out; meniscal repair; primary fixation; SUTURE MATERIAL; FAILURE; STRENGTH; SYSTEM; LOAD;
D O I
10.1177/23259671231209951
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background:Biomechanical assessment of meniscal repairs is essential for evaluating different meniscal suturing methods and techniques. The continuous meniscal suture technique is a newer method of meniscal repair that may have biomechanical differences compared with traditional techniques.Purpose:To evaluate the displacement, stiffness after cyclical loading, and load to failure for a continuous vertical inside-out meniscal suture versus a traditional vertical inside-out meniscal suture in a porcine medial meniscus.Study Design:Controlled laboratory study.Methods:A total of 28 porcine knees were acquired and divided into 2 test groups of 14 medial meniscus each. A 2.0-cm longitudinal red-white zone cut was made in the body of the medial meniscus for each knee. The continuous suture (CS) group received 4 vertical stitches performed with a continuous vertical meniscal suture technique, and the inside-out suture (IO) group received a traditional vertical suture with 4 stitches. Two traction tapes were passed between the sutures and positioned in the biomechanical testing fixture device. Each specimen underwent load-to-failure testing at 5 mm/s, and displacement, system stiffness, and maximum load to failure were compared between the groups.Results:The displacement after the cyclic test was 0.53 +/- 0.12 and 0.48 +/- 0.07 mm for the CS and IO groups, respectively. There was no significant difference between the groups (P = .2792). The stiffness at the ultimate load testing was 36.3 +/- 1.9 and 35.3 +/- 2.4 N/mm for groups CS and IO, respectively, with no significant difference between the groups (P = .2557). In the load-to-failure test, the ultimate load was 218.2 +/- 63.9 and 238.3 +/- 71.3 N in the CS and IO groups, respectively, with no significant group differences (P = .3062).Conclusion:A continuous vertical meniscal suture created a configuration for treating longitudinal meniscal lesions that was beneficial and biomechanically similar to a traditional vertical suture technique.Clinical Relevance:The study findings indicate that use of the continuous vertical inside-out meniscal suture technique is a possible therapeutic option.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Comparison of All-Inside Meniscal Repair Devices with Matched Inside-Out Suture Repair
    Rosso, Claudio
    Kovtun, Konstantin
    Nazarian, Ara
    DeAngelis, Joseph P.
    Ramappa, Arun
    [J]. SWISS MEDICAL WEEKLY, 2011, 141 : 30S - 30S
  • [12] Inside-Out Meniscus Repair
    Nelson, Clay G.
    Bonner, Kevin F.
    [J]. ARTHROSCOPY TECHNIQUES, 2013, 2 (04): : E453 - E460
  • [13] Inside-out meniscus repair
    Watson, FJ
    Arciero, RA
    [J]. OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (02) : 104 - 126
  • [14] Effect of inside-out meniscal repair on meniscal dimension in meniscal tear patients
    Kinoshita, Takuya
    Hashimoto, Yusuke
    Nishino, Kazuya
    Iida, Ken
    Nakamura, Hiroaki
    [J]. ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2024, 36 : 50 - 57
  • [15] Inside-Out
    Werfel, T.
    [J]. HAUTARZT, 2009, 60 (10): : 802 - +
  • [16] Meniscal Repair Using the Inside-Out Technique with Cross Stitch
    Cruz-Lopez, Francisco
    Trueba, Cesareo
    Almazan, Arturo
    Sierra, Luis
    Francisco, Perez
    Villalobos-Cordova, Enrique
    Ibarra, Clemente
    [J]. SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2012, 20 (02): : 101 - 105
  • [17] Inside-Out Versus All-Inside Repair of Isolated Meniscal Tears: An Updated Systematic Review
    Fillingham, Yale A.
    Riboh, Jonathan C.
    Erickson, Brandon J.
    Bach, Bernard R., Jr.
    Yanke, Adam B.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2017, 45 (01): : 234 - 242
  • [18] All-inside versus inside-out meniscal repair: A systematic review and meta-analysis
    Vint, Helen
    Quartley, Megan
    Robinson, James R.
    [J]. KNEE, 2021, 28 : 326 - 337
  • [19] A simple device for inside-out meniscal suture
    Espejo-Baena, A
    Urbano-Labajos, V
    del Pino, MJR
    Peral-Infantes, I
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (08): : e85 - e87
  • [20] Comparison of Inside-Out and All-Inside Techniques for the Repair of Isolated Meniscal Tears A Systematic Review
    Grant, John A.
    Wilde, Jeff
    Miller, Bruce S.
    Bedi, Asheesh
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (02): : 459 - 468