Performance Evaluation of Various Z-Source Inverter Topologies for PV Applications Using AI-Based MPPT Techniques

被引:8
|
作者
Kalaiarasi, N. [1 ]
Sivapriya, A. [1 ]
Vishnuram, Pradeep [1 ]
Pushkarna, Mukesh [2 ]
Bajaj, Mohit [3 ,4 ,5 ]
Kotb, Hossam [6 ]
Alphonse, Sadam [7 ]
机构
[1] SRM Inst Sci & Technol, Dept Elect & Elect Engn, Kattankulathur 603203, Tamilnadu, India
[2] GLA Univ, Dept Elect Engn, Mathura 281406, India
[3] Graphic Era, Dept Elect Engn, Dehra Dun 248002, India
[4] Graphic Era Hill Univ, Dehra Dun 248002, India
[5] Appl Sci Private Univ, Appl Sci Res Ctr, Amman 11937, Jordan
[6] Alexandria Univ, Fac Engn, Dept Elect Power & Machines, Alexandria, Egypt
[7] Univ Ngaoundere, Lab Anal Simulat & Testing, UFD PAI, POB 455, Ngaoundere, Cameroon
关键词
ALGORITHM; SYSTEM;
D O I
10.1155/2023/1134633
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent research has been focussed on renewable energy due to the rising need for electrical energy. Renewable energy has a low environmental impact compared to other energy sources. As a result, renewable energy sources (RESs) are the best option for generating electricity. Solar photovoltaic is one of the largest renewable power generators. Solar photovoltaic (PV) is connected to the load via power electronic converters. Most PV installations need a two-stage conversion process consisting of a boost converter to increase the load voltage and an AC-to-DC voltage source inverter to power the load. The Z-source inverter (ZSI) can confront the shortcomings of VSI and two-stage conversions. ZSI connects the PV system to the load and is used to increase the system's performance. This paper discusses the performance of various topologies of ZSI, such as traditional Z-source inverters (XZSIs); for integrating a PV source into a load, switched inductor Z-source inverters (SIZSIs) and transient Z-source inverters (TZSIs) are used. Also, artificial neural networks (ANNs), fuzzy logic controller (FLC), and adaptive neuro-fuzzy inference system (ANFIS)-based MPPT techniques are discussed for obtaining maximum power from PV panels. Based on the maximum power, the shoot-through duty ratio has been adjusted.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Z-source inverter for a single-phase PV system based on sliding-mode control
    Department of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2008, 21 (33-39):
  • [42] Fault diagnosis and reconfiguration for multilevel inverter drive using AI-based techniques
    Khomfoi, Surin
    Tolbert, Leon M.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (06) : 2954 - 2968
  • [43] Model Predictive Control Strategy-Based Voltage Sensing of Quasi Z-Source Cascaded Multi-Level PV Inverter with Distributed MPPT Algorithm
    Kumar, M. Senthil
    Vishnupriyan, J.
    Kumar, Nallapaneni Manoj
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2020, 10 (01): : 183 - 192
  • [44] Investigation of Dynamic Performance of Grid Connected Z-Source Inverter Based Distributed Generation
    Kadwane, Sumant G.
    Venkatesan, Suresh
    Gawande, S. P.
    Keshri, Ritesh
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [45] Real-time performance evaluation of Quasi Z-Source Inverter for Induction Motor Drives
    Maity, Tanmoy
    Prasad, Hanuman
    2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 844 - 849
  • [46] MPPT algorithm of particle swarm optimization and fuzzy variable step incremental conductance method based on Z-source inverter
    Mei, Runjie
    Zhang, Jingwei
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (01): : 137 - 145
  • [47] An enhanced single phase quasi Z-source switched capacitor seven level inverter with modified SPWM for PV applications
    Hosseini, Semko
    Hosseini, Seyed Hossein
    Sabahi, Mehran
    Babaei, Ebrahim
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [48] Performance of Distributed DC Power System using Quasi Z-Source Inverter Based DC/DC Converters
    Siwakoti, Yam P.
    Town, Graham E.
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 1946 - 1953
  • [49] Extremum Seeking-Based Model Predictive MPPT for Grid-Tied Z-Source Inverter for Photovoltaic Systems
    Sajadian, Sally
    Ahmadi, Reza
    Zargarzadeh, Hassan
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2019, 7 (01) : 216 - 227
  • [50] 3-LEVEL Z-SOURCE INVERTER BASED PV SYSTEM WITH BIDIRECTIONAL BUCK-BOOST BESS
    Harshit
    Bhattacharya, Avik
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,