Quantitative Assessment of Tissue Stiffness Using Transfer Learning Ultrasound Elastography: A Breast Cancer Phantom Study

被引:0
|
作者
An, Justin [1 ]
Abdus-Shakur, Tasneem [1 ,2 ]
Denis, Max [1 ,2 ]
机构
[1] Univ Dist Columbia, Dept Mech Engn, Washington, DC 20008 USA
[2] Univ Dist Columbia, Biomed Engn Program, Washington, DC 20008 USA
基金
美国国家卫生研究院;
关键词
Sensor signal processing; transfer learning ultrasound elastography; breast cancer; cancer; elastography; strain imaging; ultrasound;
D O I
10.1109/LSENS.2023.3307102
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this letter, a phantom study is performed to investigate the feasibility of quantitative tissue stiffness assessment of breast cancer masses using transfer learning ultrasound elastography. Ultrasound elastography is an imaging modality developed to enhance the low specificity of conventional ultrasound, utilizing manual tissue compression, and tracked strain deformation to reconstruct a color-coded qualitative 2-D tissue stiffness map (elastograms). Elastogram assessment in breast cancer screening is based on the working principle that normal tissue is less stiff than benign and malignant breast masses. A transfer learning ultrasound elastography model is developed to classify the breast masses into quantifiable Young's modulus (kilopascals, kP) values. The transfer learning model combines features of images from ultrasound elastography elastograms and from Google's deep learning model AlexNet. The elastogram features used in the training and validation of the transfer learning model were obtained from a CIRS-049 phantom with inclusions having various Young's moduli. The model was evaluated on a CIRS-059 breast phantom with spherical inclusions. Test results show that the transfer learning model yields greater than 88% validation accuracy. Therefore, with the computer-aided tool of transfer learning, ultrasound elastography has the potential of quantitatively differentiating benign and malignant breast masses based on tissue stiffness values.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Can Tissue Stiffness Measured Using Shear-Wave Elastography Represent Lymphedema in Breast Cancer?
    Lee, Dong Gyu
    Cho, Jang Hyuk
    LYMPHATIC RESEARCH AND BIOLOGY, 2022, 20 (06) : 607 - 611
  • [22] Comparison of liver stiffness assessment by transient elastography and shear wave elastography using six ultrasound devices
    Iijima, Hiroko
    Tada, Toshifumi
    Kumada, Takashi
    Kobayashi, Natsuko
    Yoshida, Masahiro
    Aoki, Tomoko
    Nishimura, Takashi
    Nakano, Chikage
    Ishii, Akio
    Takashima, Tomoyuki
    Sakai, Yoshiyuki
    Aizawa, Nobuhiro
    Nishikawa, Hiroki
    Ikeda, Naoto
    Iwata, Yoshinori
    Enomoto, Hirayuki
    Ide, Yoshi-Hiro
    Hirota, Seiichi
    Fujimoto, Jiro
    Nishiguchi, Shuhei
    HEPATOLOGY RESEARCH, 2019, 49 (06) : 676 - 686
  • [23] Quantitative assessment of muscular stiffness in children with cerebral palsy using acoustic radiation force impulse (ARFI) ultrasound elastography
    Meltem Ceyhan Bilgici
    Tumay Bekci
    Yasemin Ulus
    Hamit Ozyurek
    Omer Faruk Aydin
    Leman Tomak
    Mustafa Bekir Selcuk
    Journal of Medical Ultrasonics, 2018, 45 : 295 - 300
  • [24] Quantitative assessment of muscular stiffness in children with cerebral palsy using acoustic radiation force impulse (ARFI) ultrasound elastography
    Bilgici, Meltem Ceyhan
    Bekci, Tumay
    Ulus, Yasemin
    Ozyurek, Hamit
    Aydin, Omer Faruk
    Tomak, Leman
    Selcuk, Mustafa Bekir
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (02) : 295 - 300
  • [25] Quantitative Assessment of Muscular Stiffness in Children With Chronic Kidney Disease Using Acoustic Radiation Force Impulse Ultrasound Elastography
    Bekci, Tumay
    Bilgici, Meltem Ceyhan
    Tekcan, Demet
    Ulus, Yasemin
    Akyuz, Behic
    ULTRASOUND QUARTERLY, 2021, 37 (01) : 63 - 67
  • [26] Motion effects on the measurement of stiffness on ultrasound shear wave elastography: a moving liver fibrosis phantom study
    Shin, Hyun Joo
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Lee, Kwanseop
    Lee, Kwan Sik
    Park, Jong-Chul
    Lee, Mi-Jung
    Yoon, Haesung
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) : 14 - 20
  • [27] Comparative Study of Ultrasound Tissue Motion Tracking Techniques for Effective Breast Ultrasound Elastography
    Caius, Matthew
    Samani, Abbas
    APPLIED SCIENCES-BASEL, 2023, 13 (21):
  • [28] Quantitative Assessment of Left Ventricular Diastolic Stiffness Using Cardiac Shear Wave Elastography A Pilot Study
    Song, Pengfei
    Bi, Xiaojun
    Mellema, Daniel C.
    Manduca, Armando
    Urban, Matthew W.
    Greenleaf, James F.
    Chen, Shigao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (07) : 1419 - 1427
  • [29] Quantitative stiffness assessment of cardiac grafts using ultrasound in a porcine model: A tissue biomarker for heart transplantation
    Pedreira, Olivier
    Papadacci, Clement
    Augeul, Lionel
    Loufouat, Joseph
    Tanter, Mickael
    Pernot, Mathieu
    Ferrera, Rene
    Pernota, Mathieu
    EBIOMEDICINE, 2022, 83
  • [30] PB.45. Correlation of perilesional tissue stiffness measured by ultrasound strain elastography with breast density
    A Di Batista
    R English
    R Sidebottom
    R Adams
    L Winter
    A Noble
    A Harris
    Breast Cancer Research, 16 (Suppl 1)