Strategies for sensor virtual in-situ calibration in building energy system: Sensor evaluation and data-driven based methods

被引:7
|
作者
Li, Jiteng [1 ]
Wang, Peng [1 ]
Han, Xing [2 ]
Zhao, Tianyi [1 ]
Yoon, Sungmin [3 ,4 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian, Peoples R China
[2] PCI Technol Grp, Guangzhou, Peoples R China
[3] Sungkyunkwan Univ, Sch Civil Architectural Eng & Landscape Architectu, Suwon 16419, South Korea
[4] Sungkyunkwan Univ, Dept Global Smart City, Suwon 16419, South Korea
基金
中国国家自然科学基金;
关键词
Sensor virtual in-situ calibration; Sensor error; Sensor evaluation; Data-driven based methods; Variable air volume system; FAULT-DETECTION; HIDDEN FACTORS; OPTIMIZATION; DIAGNOSIS; NETWORK;
D O I
10.1016/j.enbuild.2023.113274
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sensor errors greatly affect the optimal control, safe operation, and energy efficiency of the building energy system. The sensor virtual in-situ calibration (VIC) method based on Bayesian inference can calibrate the sensor errors and does not need to remove existing sensors or add redundant sensors. In the previous study, the calibration of all sensors (non-differential calibration) and the physical model-driven based methods are applied in the simulation system. However, in the practical building energy system, these reduce calibration accuracy and efficiency. To solve these two negative factors, two calibration strategies are proposed: (1) sensor evaluation, and (2) data-driven based methods. Four cases are designed to demonstrate calibration accuracy and efficiency improvement by applying the calibration strategies in the variable air volume system. The results show that nondifferential calibration causes difficulties in practical applications because of its low accuracy (38.10 %) and long calibration time (5136.35 s). The calibration accuracy of the physical model-driven based methods is 9.06 %, which completely deviates from the true value. The two calibration strategies are applied to improve the sensor calibration accuracy (up to 91.88 %) and reduce the calibration time (28.99 %) although it will increase some replacement costs. Meantime, the calibration accuracy of the temperature sensor is further improved (exceeding 94 %) by dividing the operating conditions according to the compressor power. In summary, the application of the calibration strategies can effectively overcome the negative impacts on calibration accuracy and efficiency, and increase the robustness of the VIC method in the practical building energy system.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Improvement for energy efficiency and control characteristics in variable air volume system using in-situ sensor calibration method based on autoencoder
    Li, Jiteng
    Wang, Peng
    Li, Jiqing
    Xing, Han
    Zhao, Tianyi
    Yoon, Sungmin
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [32] A Data-Driven Architecture for Sensor Validation Based on Neural Networks
    Darvishi, Hossein
    Ciuonzo, Domenico
    Eide, Eivind Roson
    Rossi, Pierluigi Salvo
    2020 IEEE SENSORS, 2020,
  • [33] Data-Driven Stochastic Models and Policies for Energy Harvesting Sensor Communications
    Ku, Meng-Lin
    Chen, Yan
    Liu, K. J. Ray
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2015, 33 (08) : 1505 - 1520
  • [34] In-situ Calibration Method of Fiber Grating Strain Sensor Based on Data Sequence Matching and Statistical Analysis
    Cai Jingyi
    Wu Jieya
    Zhao Chunliu
    Kang Juan
    Gong Huaping
    ACTA PHOTONICA SINICA, 2022, 51 (06)
  • [35] A novel data-driven technique to produce multi- sensor virtual responses for gas sensor array-based electronic noses
    Srivastava, Sumit
    Chaudhri, Shiv Nath
    Rajput, Navin Singh
    Mishra, Ashutosh
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2023, 74 (02): : 102 - 108
  • [36] Single to Multi: Data-Driven High Resolution Calibration Method for Piezoresistive Sensor Array
    Kim, Min
    Choi, Hyungmin
    Cho, Kyu-Jin
    Jo, Sungho
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2021, 6 (03) : 4970 - 4977
  • [37] A study on the sensor calibration method using data-driven prediction in VAV terminal unit
    Kim, Hyo-Jun
    Cho, Young-Hum
    Lee, Sang-Hoon
    ENERGY AND BUILDINGS, 2022, 258
  • [38] Real-Time In-Situ Calibration for Angle Measuring Sensor Based on Autocollimator
    Zhang W.
    Zhu H.
    Li M.
    Guo Z.
    Guo M.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2019, 46 (04):
  • [39] Real-Time In-Situ Calibration for Angle Measuring Sensor Based on Autocollimator
    Zhang Wenying
    Zhu Haoran
    Li Meixuan
    Guo Zexuan
    Guo Ming
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (04):
  • [40] Staging Based Task Execution for Data-driven, In-Situ Scientific Workflows
    Wang, Zhe
    Subedi, Pradeep
    Dorier, Matthieu
    Davis, Philip E.
    Parashar, Manish
    2020 IEEE INTERNATIONAL CONFERENCE ON CLUSTER COMPUTING (CLUSTER 2020), 2020, : 209 - 220