An MMC based HVDC system with optimized AC fault ride-through capability and enhanced circulating current suppression control

被引:0
|
作者
Badar, Jahangeer [1 ]
Akhtar, Faheem [1 ]
Kumar, Dileep [1 ]
Munir, Hafiz Mudassir [1 ]
Ali, Khawaja Haider [1 ]
Alsaif, Faisal [2 ]
Alsulamy, Sager [3 ]
机构
[1] Sukkur IBA Univ, Dept Elect Engn, Sukkur, Sindh, Pakistan
[2] King Saud Univ, Coll Engn, Dept Elect Engn, Riyadh, Saudi Arabia
[3] Univ Southampton, Fac Engn & Phys Sci, Energy & Climate Change Div, Sustainable Energy Res Grp, Southampton, England
关键词
HVDC; fault ride-through (FRT); modular multilevel converter (MMC); circulating current control circuit; stability; MODULAR MULTILEVEL CONVERTERS; CONTROL STRATEGY; WIND TURBINES; SIDE;
D O I
10.3389/fenrg.2023.1190975
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Modular multilevel converter (MMC) is a proven technology for HVDC applications due to its salient features such as modularity and excellent power quality. To ensure best possible grid support, recent grid codes require incorporating fault ride-through (FRT) strategies so that HVDC converter stations remain connected and maintain reliable operation under various symmetrical and asymmetrical AC faults. In this paper, a communication-free enhanced fault ride-through technique without the need of DC chopper has been proposed. The proposed FRT strategy ensures quick post fault recovery operation and can effectively manage DC link and capacitor voltages within safe limits. Along with proposed FRT strategy, in order to avoid high circulating current (CC) inside an MMC, this paper has proposed an optimal circulating current control approach based on proportional resonant and PI controllers in an abc reference frame. The suggested technique lowers the ripple in capacitor voltages while reducing the magnitude of the CC. Under both balanced and unbalanced ac grid conditions, the ripple in the dc link voltage is also reduced without the use of dual synchronous reference frame or any additional controllers. Simulation results confirm the effectiveness of the proposed FRT and CC suppression techniques for a 580-kV, 850-MW MMC-based HVDC system.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Application of MMC with Embedded Energy Storage for Overvoltage Suppression and Fault Ride-through Improvement in Series LCC-MMC Hybrid HVDC System
    Li, Xiaodong
    Xu, Zheng
    Zhang, Zheren
    [J]. JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (03) : 1001 - 1013
  • [32] Research on the Modeling of MMC-HVDC Considering the Fault Ride-through Characteristics
    Li Xia
    Ye Xiaohui
    Song Xingli
    Fan Yunlong
    Liu Tao
    Wu Guoyang
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 244 - 248
  • [33] An improved topology of isolated MMC with fault ride-through capability under MVDC fault
    Li, Liangzi
    Liu, Zhijie
    Sun, Kaiqi
    Wang, Jianjian
    Li, Ke-Jun
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
  • [34] Coordinated Control Strategy of DC Fault Ride-through for the WF Connected to the Grid Through the MMC-HVDC
    Zhu, Bo
    Li, Hongying
    Xu, Panteng
    Jiao, Shi
    Zhang, Lin
    Xin, Yechun
    [J]. FRONTIERS IN ENERGY RESEARCH, 2021, 9 (09):
  • [35] A Direct Current-Synchronization Control for Voltage Source Converter with Enhanced Fault Ride-Through Capability
    Zeng, Zheran
    Yang, Dongsheng
    Wu, Heng
    Shu, Liangcai
    Sun, Yin
    Wang, Songda
    [J]. IEEE Open Journal of Power Electronics, 2024, 5 : 1484 - 1499
  • [36] Coordinated control strategy for receiving-end AC fault ride-through of an MMC-HVDC connecting offshore wind power
    Li, Guoqing
    Xu, Yanan
    Jiang, Shouqi
    Wang, Limeng
    Xin, Yechun
    Wang, Lixin
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (07): : 111 - 119
  • [37] Fast Pre-charge Strategy of a Modified MMC with Enhanced DC Fault Ride-through Capability
    Li, Dongye
    Sun, Yichao
    Zhao, Jianfeng
    Ji, Zhendong
    [J]. 2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 717 - 722
  • [38] A Novel Symmetrical MMC Submodule Topology With DC Fault Ride-through Capability
    Tao, Jianye
    Wang, Chen
    Wang, Yi
    Xu, Tong
    Nie, Xiaopeng
    Wei, Ziwen
    [J]. 2021 IEEE 12TH ENERGY CONVERSION CONGRESS AND EXPOSITION - ASIA (ECCE ASIA), 2021, : 1099 - 1104
  • [39] Investigation of a Hybrid HVDC System with DC Fault Ride-Through and Commutation Failure Mitigation Capability
    Guo, Chunyi
    Zhao, Chengyong
    Peng, Maolan
    Liu, Wei
    [J]. JOURNAL OF POWER ELECTRONICS, 2015, 15 (05) : 1367 - 1379
  • [40] DC Pole-to-ground Fault Ride-through Strategy of Hybrid HVDC System Based on LCC and Hybrid MMC
    Zhang D.
    Fan Z.
    Xu H.
    Miao S.
    Wang Y.
    Liu Z.