Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography

被引:0
|
作者
Takahashi, Junji [1 ,2 ]
Machida, Yoshio [2 ]
Fukuzawa, Kei [1 ]
Tsuji, Yoshinori [1 ]
Ohmoto-Sekine, Yuki [3 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol Technol, 2-2-2 Toranomon,Minato Ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Hlth Sci, 2-1 Seiryo Machi,Aoba Ku, Sendai, Miyagi 9808575, Japan
[3] Toranomon Gen Hosp, Hlth Management Ctr, 2-2-2 Toranomon,Minato-ku, Tokyo 1058470, Japan
关键词
Coronary magnetic resonance angiography; Image quality; Compressed sensing; Acceleration factor; Denoising factor; STATE FREE PRECESSION; PARTIALLY PARALLEL ACQUISITIONS; MR-ANGIOGRAPHY; RELAXATION; NOISE; TIME;
D O I
10.1007/s12194-024-00787-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using numerical indices and visual evaluation, we evaluated the dependence of coronary-artery depictability on the denoising parameter in compressed sensing magnetic resonance angiography (CS-MRA). This study was conducted to clarify the acceleration factor (AF) and denoising factor (DF) dependence of CS-MRA image quality. Vascular phantoms and clinical images were acquired using three-dimensional CS-MRA on a clinical 1.5 T system. For the phantom measurements, we compared the full width at half maximum (FWHM), sharpness, and contrast ratio of the vascular profile curves for various AFs and DFs. In the clinical cases, the FWHM, sharpness, contrast ratio, signal-to-noise ratio, noise level values, and visual evaluation results were compared for various DFs. Phantom image analyses demonstrated that the respective measurements of the FWHM, sharpness, and contrast ratios did not significantly change with an increase in AF. The FWHM and sharpness measurements slightly changed with the DF level. However, the contrast ratio tended to increase with an increase in the DF level. In the clinical cases, the FWHM and sharpness showed no significant differences, even when the DF level was changed. However, the contrast ratio tended to decrease as the DF level increased. When the DF levels of the clinical cases increased, the background signals of the myocardium, fat, and noise levels decreased. We investigated the dependence of the coronary-artery depictability on AF and DF using CS-MRA. Analysis of the coronary-artery profile curves indicated that a better image quality was achieved with a stronger DF on coronary CS-MRA.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 50 条
  • [21] Coronary magnetic resonance angiography
    Danias, PG
    Hauser, TH
    Katsimaglis, G
    Botnar, RM
    Manning, WJ
    HERZ, 2003, 28 (02) : 90 - +
  • [22] Coronary magnetic resonance angiography
    Stuber, Matthias
    Weiss, Robert G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) : 219 - 234
  • [23] Magnetic resonance coronary angiography
    Phillip C. Yang
    Michael V. McConnell
    Dwight G. Nishimura
    Bob S. Hu
    Current Cardiology Reports, 2003, 5 (1) : 55 - 62
  • [24] Coronary magnetic resonance angiography
    Blankenship, J
    Iliadis, L
    NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (18): : 1413 - 1413
  • [25] Evaluation of rerouting surgery of a coronary artery anomaly by magnetic resonance angiography
    Salm, LP
    Bax, JJ
    Lamb, HJ
    Hazekamp, MG
    de Roos, A
    van der Wall, EE
    Vliegen, HW
    ANNALS OF THORACIC SURGERY, 2003, 76 (05): : 1748 - 1748
  • [26] Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography
    Sakuma, Hajime
    Ichikawa, Yasutaka
    Chino, Shuji
    Hirano, Tadanori
    Makino, Katsutoshi
    Takeda, Kan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) : 1946 - 1950
  • [27] Assessment of Coronary Artery Disease Using Magnetic Resonance Coronary Angiography: A Multicenter Trial
    Kato, Shingo
    Sakuma, Hajime
    Ishida, Nanaka
    Ishida, Masaki
    Nagata, Motonori
    Ichikawa, Yasutaka
    Kataoka, Kazuhiro
    Matsumoto, Yuji
    Seo, Hiroshi
    Ochiai, Reiji
    Kobayashi, Yasuyuki
    CIRCULATION, 2008, 118 (18) : S778 - S778
  • [28] The improved detection of coronary artery stenoses with a combination of magnetic resonance coronary angiography and perfusion
    Bunce, N
    EUROPEAN HEART JOURNAL, 2001, 22 : 6 - 6
  • [29] Impaired Coronary Vasodilation by Magnetic Resonance Angiography Is Associated With Advanced Coronary Artery Calcification
    Terashima, Masahiro
    Nguyen, Patricia K.
    Rubin, Geoffrey D.
    Iribarren, Carlos
    Courtney, Brian K.
    Go, Alan S.
    Fortmann, Stephen P.
    McConnell, Michael V.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (02) : 167 - 173
  • [30] Ferumoxytol-Enhanced Coronary Magnetic Resonance Angiography Compared to Invasive Coronary Angiography for Detection of Epicardial Coronary Artery Disease
    Miller, Timothy
    Chin, Mathew S.
    Gharagouzloo, Codi
    Aghayev, Ayaz
    Zheng, Sijie
    Kwong, Raymond
    Memon, Aliza Anwar
    Siedlecki, Andrew M.
    KIDNEY MEDICINE, 2021, 3 (01) : 139 - 141