Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography

被引:0
|
作者
Takahashi, Junji [1 ,2 ]
Machida, Yoshio [2 ]
Fukuzawa, Kei [1 ]
Tsuji, Yoshinori [1 ]
Ohmoto-Sekine, Yuki [3 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol Technol, 2-2-2 Toranomon,Minato Ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Hlth Sci, 2-1 Seiryo Machi,Aoba Ku, Sendai, Miyagi 9808575, Japan
[3] Toranomon Gen Hosp, Hlth Management Ctr, 2-2-2 Toranomon,Minato-ku, Tokyo 1058470, Japan
关键词
Coronary magnetic resonance angiography; Image quality; Compressed sensing; Acceleration factor; Denoising factor; STATE FREE PRECESSION; PARTIALLY PARALLEL ACQUISITIONS; MR-ANGIOGRAPHY; RELAXATION; NOISE; TIME;
D O I
10.1007/s12194-024-00787-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using numerical indices and visual evaluation, we evaluated the dependence of coronary-artery depictability on the denoising parameter in compressed sensing magnetic resonance angiography (CS-MRA). This study was conducted to clarify the acceleration factor (AF) and denoising factor (DF) dependence of CS-MRA image quality. Vascular phantoms and clinical images were acquired using three-dimensional CS-MRA on a clinical 1.5 T system. For the phantom measurements, we compared the full width at half maximum (FWHM), sharpness, and contrast ratio of the vascular profile curves for various AFs and DFs. In the clinical cases, the FWHM, sharpness, contrast ratio, signal-to-noise ratio, noise level values, and visual evaluation results were compared for various DFs. Phantom image analyses demonstrated that the respective measurements of the FWHM, sharpness, and contrast ratios did not significantly change with an increase in AF. The FWHM and sharpness measurements slightly changed with the DF level. However, the contrast ratio tended to increase with an increase in the DF level. In the clinical cases, the FWHM and sharpness showed no significant differences, even when the DF level was changed. However, the contrast ratio tended to decrease as the DF level increased. When the DF levels of the clinical cases increased, the background signals of the myocardium, fat, and noise levels decreased. We investigated the dependence of the coronary-artery depictability on AF and DF using CS-MRA. Analysis of the coronary-artery profile curves indicated that a better image quality was achieved with a stronger DF on coronary CS-MRA.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 50 条
  • [1] Comparison of compressed sensing and conventional coronary magnetic resonance angiography for detection of coronary artery stenosis
    Ogawa, Ryo
    Kido, Tomoyuki
    Nakamura, Masashi
    Tanabe, Yuki
    Kurata, Akira
    Schmidt, Michaela
    Forman, Christoph
    Komori, Yoshiaki
    Watanabe, Kouki
    Kido, Teruhito
    Mochizuki, Teruhito
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [2] Feasibility of contrast-enhanced coronary artery magnetic resonance angiography using compressed sensing
    Hirai, Kuniaki
    Kido, Teruhito
    Kido, Tomoyuki
    Ogawa, Ryo
    Tanabe, Yuki
    Nakamura, Masashi
    Kawaguchi, Naoto
    Kurata, Akira
    Watanabe, Kouki
    Yamaguchi, Osamu
    Schmidt, Michaela
    Forman, Christoph
    Mochizuki, Teruhito
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [3] Feasibility of contrast-enhanced coronary artery magnetic resonance angiography using compressed sensing
    Kuniaki Hirai
    Teruhito Kido
    Tomoyuki Kido
    Ryo Ogawa
    Yuki Tanabe
    Masashi Nakamura
    Naoto Kawaguchi
    Akira Kurata
    Kouki Watanabe
    Osamu Yamaguchi
    Michaela Schmidt
    Christoph Forman
    Teruhito Mochizuki
    Journal of Cardiovascular Magnetic Resonance, 22
  • [4] Coronary artery magnetic resonance angiography
    Flamm, SD
    Muthupillai, R
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 686 - 709
  • [5] Compressed Sensing Reconstruction for Magnetic Resonance Parameter Mapping
    Doneva, Mariya
    Boernert, Peter
    Eggers, Holger
    Stehning, Christian
    Senegas, Julien
    Mertins, Alfred
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) : 1114 - 1120
  • [6] Magnetic resonance angiography with compressed sensing: An evaluation of moyamoya disease
    Yamamoto, Takayuki
    Okada, Tomohisa
    Fushimi, Yasutaka
    Yamamoto, Akira
    Fujimoto, Koji
    Okuchi, Sachi
    Fukutomi, Hikaru
    Takahashi, Jun C.
    Funaki, Takeshi
    Miyamoto, Susumu
    Stalder, Aurelien F.
    Natsuaki, Yutaka
    Speier, Peter
    Togashi, Kaori
    PLOS ONE, 2018, 13 (01):
  • [7] User-guided Compressed Sensing for Magnetic Resonance Angiography
    Zhang, Changgong
    van de Giessen, Martijn
    Eisemann, Elmar
    Vilanova, Anna
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2416 - 2419
  • [8] Deep Learning-Based Acceleration of Compressed Sensing for Noncontrast-Enhanced Coronary Magnetic Resonance Angiography in Patients With Suspected Coronary Artery Disease
    Wu, Xi
    Deng, Liping
    Li, Wanjiang
    Peng, Pengfei
    Yue, Xun
    Tang, Lu
    Pu, Qian
    Ming, Yue
    Zhang, Xiaoyong
    Huang, Xiaohua
    Chen, Yucheng
    Huang, Juan
    Sun, Jiayu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (05) : 1521 - 1530
  • [9] Application of Region of Interest Compressed Sensing to Accelerate Magnetic Resonance Angiography
    Konar, Amaresha Shridhar
    Aiholli, Shivaraj
    Shashikala, H. C.
    Babu, Ramesh D. R.
    Geethanath, Sairam
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2428 - 2431
  • [10] Magnetic resonance angiography versus conventional coronary angiography to diagnose coronary artery disease
    Schlueter, M
    Tuebler, T
    Steffens, JC
    Schofer, J
    EUROPEAN HEART JOURNAL, 2002, 23 : 304 - 304