Case Study: Optimizing Grading Ring Design for High Voltage Polymeric Insulators in Power Transmission Systems for Enhanced Electric Field and Voltage Distribution by Using a Finite Element Method

被引:6
|
作者
Aziz, Esraa [1 ]
Aouabed, Fatiha [2 ]
Abdellah, Hossam [3 ]
Dineva, Adrienn [4 ]
机构
[1] Egyptian Elect Holding Co, South Cairo Elect Distribut Co, Minist Elect & Renewable Energy, Cairo 11611, Egypt
[2] Univ Mohamed El Bashir El Ibrahimi, Dept Elect Engn, Bordj Bou Arreridj 34000, Algeria
[3] UMR Ind, Cairo 4954160, Egypt
[4] Szecheny Istvan Univ, Audi Hungaria Fac Automot Engn, H-9026 Gyor, Hungary
关键词
grading ring; electric potential; electric field; finite element method (FEM); polymeric insulator; POTENTIAL DISTRIBUTION; COMPOSITE INSULATOR; HV INSULATORS;
D O I
10.3390/en16135235
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This research paper aims to investigate the optimal design of grading rings for high-voltage polymeric insulators in an actual power transmission system, with a focus on improving the electrical representation of the insulator strings. One such subsidiary accessory commonly used with porcelain and polymer insulator strings is the grading ring, which is employed to improve the electric field and voltage distribution surrounding the insulator string. The efficiency of insulator strings can be enhanced by grading rings, as they facilitate a more linear potential division along the strings. The design parameters of grading rings significantly influence their performance on insulator strings. In this study, we examine the optimal design of the grading rings of high-voltage polymer insulators, since no uniform design methodology has been developed for high-voltage polymer insulators, and their optimization is currently the subject of many research studies. The electric field on an outdoor polymeric insulator is examined using finite element method (FEM) software and COMSOL Multi-Physics program. A 2D model is utilized to simulate a 220 kV polymeric insulator. The effectiveness of high-voltage polymeric insulators greatly depends on the dimensions and locations of the grading rings. Therefore, the impacts of the radius of the grading ring and that of its tube and the tube's vertical position are thoroughly investigated, under dry and humid conditions. To achieve this objective, a search algorithm is employed to adjust the dimensions and locations of the grading ring. The optimization approach in this study is based on determining the maximum electric field across the insulator surface, while ensuring that it remains below the corona initiation level.
引用
收藏
页数:24
相关论文
共 46 条
  • [41] Two-Stage Electric Field Optimization Method for High-Voltage Power Module Using Dielectrically Graded Insulation Micro-Region
    Yao, Huanmin
    Mu, Haibao
    Li, Wendong
    Zhang, Daning
    Zhao, Haoxiang
    Wang, Chao
    Zhang, Guanjun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (03) : 1005 - 1015
  • [42] Electric field and air ion exposures near high voltage overhead power lines and adult cancers: a case control study across England and Wales
    Toledano, Mireille B.
    Shaddick, Gavin
    de Hoogh, Kees
    Fecht, Daniela
    Sterrantino, Anna Freni
    Matthews, James
    Wright, Matthew
    Gulliver, John
    Elliott, Paul
    INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2020, 49 : I57 - I66
  • [43] Calculation of the ionised field and the corona losses of high-voltage direct current transmission lines using a finite-difference-based flux tracing method
    Qiao, Ji
    Zou, Jun
    Li, Benliang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (04) : 348 - 357
  • [44] Alleviation of Electric Field Intensity in High-Voltage System by Topology and Shape Optimization of Dielectric Material Using Continuum Design Sensitivity and Level Set Method
    Lee, Kang Hyouk
    Hong, Seung Geon
    Baek, Myung Ki
    Choi, Hong Soon
    Kim, Young Sun
    Park, Il Han
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (03)
  • [45] A Frequency-Power Droop Coefficient Determination Method of Mixed Line-Commutated and Voltage-Sourced Converter Multi-Infeed, High-Voltage, Direct Current Systems: An Actual Case Study in Korea
    Lee, Gyusub
    Moon, Seungil
    Hwang, Pyeongik
    APPLIED SCIENCES-BASEL, 2019, 9 (03):
  • [46] Forecasting Voltage Collapse when Large-Scale Wind Turbines Penetrated to Power Systems Using Optimally Pruned Extreme Learning Machines (OPELM) - Case Study: Electric Power System South Sulawesi-Indonesia
    Gunadin, Indar Chaerah
    Siswanto, Agus
    Safrizal, Safrizal
    Syukriyadin, Syukriyadin
    Rosyadi, Marwan
    Muslimin, Zaenab
    Gassing
    Rasyid, Ramly
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (05): : 80 - 84