Critical Power and Respiratory Compensation Point Are Not Equivalent in Patients with COPD

被引:5
|
作者
Tiller, Nicholas B. [1 ]
Porszasz, Janos [1 ]
Casaburi, Richard [1 ]
Rossiter, Harry B. [1 ]
Ferguson, Carrie [1 ,2 ]
机构
[1] UCLA Med Ctr, Inst Resp Med & Exercise Physiol, Lundquist Inst Biomed Innovat Harbor, Div Resp & Crit Care Physiol & Med, Torrance, CA USA
[2] UCLA Med Ctr, Lundquist Inst Biomed Innovat Harbor, 1124 W Carson St,CDCRC Bldg, Torrance, CA 90502 USA
基金
美国国家卫生研究院;
关键词
EXERCISE; EXERCISE LIMITATION; LUNG FUNCTION; LUNG DISEASE; OBSTRUCTIVE PULMONARY-DISEASE; MUSCLE METABOLIC-RESPONSES; DURATION RELATIONSHIP; INTENSITY EXERCISE; AEROBIC FUNCTION; WORK CAPACITY; LIMIT; PARAMETERS; THRESHOLD; FATIGUE;
D O I
10.1249/MSS.0000000000003124
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
IntroductionSeveral studies report that pulmonary oxygen uptake (V?O-2) at the respiratory compensation point (RCP) is equivalent to the V?O-2 at critical power (CP), suggesting that the variables can be used interchangeably to demarcate the threshold between heavy and severe intensity domains. However, if RCP is a valid surrogate for CP, their values should correspond even when assessed in patients with chronic obstructive pulmonary disease (COPD) in whom the "normal" mechanisms linking CP and RCP are impeded. The aim of this study was to compare V?O-2 at CP with V?O-2 at RCP in patients with COPD.MethodsTwenty-two COPD patients (14 male/8 female; forced expiratory volume in 1 s, 46% +/- 17% pred) performed ramp-incremental cycle ergometry to intolerance (5-10 W center dot min(-1)) for the determination of gas exchange threshold (GET) and RCP. CP was calculated from the asymptote of the hyperbolic power-duration relationship from 3-5 constant-power exercise tests to intolerance. CP was validated with a 20-min constant-power ride.ResultsGET was identified in 20 of 22 patients at a V?O-2 of 0.93 +/- 0.18 L center dot min(-1) (75% +/- 13% V?O-2peak), whereas RCP was identified in just 3 of 22 patients at a V?O-2 of 1.40 +/- 0.39 L center dot min(-1) (85% +/- 2% V?O-2peak). All patients completed constant-power trials with no difference in peak physiological responses relative to ramp-incremental exercise (P > 0.05). CP was 46 +/- 22 W, which elicited a V?O-2 of 1.04 +/- 0.29 L center dot min(-1) (90% +/- 9% V?O-2peak) during the validation ride. The difference in V?O-2 at 15 and 20 min of the validation ride was 0.00 +/- 0.04 L, which was not different from a hypothesized mean of 0 (P = 0.856), thereby indicating a V?O-2 steady state.ConclusionsIn COPD patients, who present with cardiopulmonary and/or respiratory-mechanical dysfunction, CP can be determined in the absence of RCP. Accordingly, CP and RCP are not equivalent in this group.
引用
收藏
页码:1097 / 1104
页数:8
相关论文
共 50 条
  • [21] Estimation of ventilation threshold in trained cyclists from the respiratory compensation point and peak power
    Parker, D
    Peiffer, J
    Faria, I
    Quintana, R
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S43 - S43
  • [22] Power-factor compensation is equivalent to cyclodissipassivation
    Garcia-Canseco, Eloisa
    Ortega, Romeo
    Grino, Robert
    Stankovic, Alexander
    2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 4617 - +
  • [23] The COPD assessment test and St George's Respiratory Questionnaire: are they equivalent in subjects with COPD?
    Morishita-Katsu, Mariko
    Nishimura, Koichi
    Taniguchi, Hiroyuki
    Kimura, Tomoki
    Kondoh, Yasuhiro
    Kataoka, Kensuke
    Ogawa, Tomoya
    Watanabe, Fumiko
    Arizono, Shinichi
    Nishiyama, Osamu
    Nakayasu, Kazuhito
    Imaizumi, Kazuyoshi
    Hasegawa, Yoshinori
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 1543 - 1551
  • [24] Relationship between functional threshold power, ventilatory threshold and respiratory compensation point in road cycling
    Sitko, Sebastian
    Cirer-Sastre, Rafel
    Corbi, Francisco
    Lopez-Laval, Isaac
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2022, 62 (05): : 626 - 632
  • [25] On the determination of ventilatory threshold and respiratory compensation point via respiratory frequency
    Cannon, Daniel T.
    Kolkhorst, Fred W.
    Buono, Michael J.
    FASEB JOURNAL, 2008, 22
  • [26] On the Determination of Ventilatory Threshold and Respiratory Compensation Point via Respiratory Frequency
    Cannon, D. T.
    Kolkhorst, F. W.
    Buono, M. J.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2009, 30 (03) : 157 - 162
  • [27] A Ventilatory Control Model Explaining the Respiratory Compensation Point
    Nicolo, Andrea
    Greco, Giuseppe
    Sacchetti, Massimo
    SPORTS MEDICINE, 2025,
  • [28] Time to Exhaustion at the Respiratory Compensation Point in Recreational Cyclists
    Moral-Gonzalez, Susana
    Gonzalez-Sanchez, Javier
    Valenzuela, Pedro L.
    Garcia-Merino, Sonia
    Barbado, Carlos
    Lucia, Alejandro
    Foster, Carl
    Barranco-Gil, David
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (17) : 1 - 9
  • [29] Functional Threshold Power: Relationship With Respiratory Compensation Point and Effects of Various Warm-Up Protocols
    Barranco-Gil, David
    Gil-Cabrera, Jaime
    Valenzuela, Pedro L.
    Alejo, Lidia B.
    Montalvo-Perez, Almudena
    Talavera, Eduardo
    Moral-Gonzalez, Susana
    Lucia, Alejandro
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2020, 15 (07) : 1047 - 1051
  • [30] Critical Point The power of authority
    Crease, Robert P.
    PHYSICS WORLD, 2020, 33 (08) : 21 - 21