摘要
When a satellite-borne detector is being ground calibrated, a standard detector is required to determine the monochromatic X-ray beam energy and intensity. For this purpose, a SiPM-based LaBr3(Ce) detector has been developed. The environmental temperature change may substantially affect the performance of the detector, thus affecting the accuracy of the ground calibration results. To study the effect of temperature change on the performance of the LaBr3(Ce) detector, the performance of the LaBr3(Ce) detector was tested with Am-241 and Cs-137 gamma-ray sources in the high- and low-temperature test chambers. The results showed that within the range of - 20 to 40 & DEG;C, the energy resolution of the LaBr3(Ce) detector does not change by more than 1%, nor does the peak-to-total ratio of Am-241 and Cs-137. The temperature change has little effect on the performance of the LaBr3(Ce) detector, which meets the requirements for use as a beam monitor. However, the peak location of the radioactive source varies significantly with temperature, and the difference with the peak location at room temperature is within 17%. To reduce the variation in the gain of the LaBr3(Ce) detector with temperature, it is necessary to optimize the compensation design of the temperature gain to ensure the stability of the detector gain at various temperatures.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 50 条
  • [21] Active Interrogation of Nuclear Materials Using LaBr3: Ce Detectors
    Omer, Mohamed
    Negm, H.
    Zen, H.
    Hori, T.
    Kii, T.
    Masuda, K.
    Ohgaki, H.
    Hajima, R.
    Hayakawa, T.
    Daito
    Shizuma, T.
    Fujiwara, M.
    Park, S. H.
    Kikuzawa, N.
    Rusev, G.
    Tonchev, A. P.
    Wu, Y. K.
    10TH ECO-ENERGY AND MATERIALS SCIENCE AND ENGINEERING SYMPOSIUM, 2013, 34 : 50 - 56
  • [22] Measurements of high-energy γ-rays with LaBr3 : Ce detectors
    Ciemala, M.
    Balabanski, D.
    Csatlos, M.
    Daugas, J. M.
    Georgiev, G.
    Gulyas, J.
    Kmiecik, M.
    Krasznahorkay, A.
    Lalkovski, S.
    Lefebvre-Schuhl, A.
    Lozeva, R.
    Maj, A.
    Vitez, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01): : 76 - 79
  • [23] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Feng, Pei-Yi
    Sun, Xi-Lei
    An, Zheng-Hua
    Deng, Yong
    Wang, Cheng-Er
    Jiang, Huang
    Li, Jun-Jie
    Zhang, Da-Li
    Li, Xin-Qiao
    Xiong, Shao-Lin
    Zheng, Chao
    Gong, Ke
    Yang, Sheng
    Liu, Xiao-Jing
    Gao, Min
    Wen, Xiang-Yang
    Liu, Ya-Qing
    Xu, Yan-Bing
    Zhao, Xiao-Yun
    Liu, Jia-Cong
    Zhang, Fan
    Lu, Hong
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (02)
  • [24] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Pei?Yi Feng
    Xi?Lei Sun
    Zheng?Hua An
    Yong Deng
    Cheng?Er Wang
    Huang Jiang
    Jun?Jie Li
    Da?Li Zhang
    Xin?Qiao Li
    Shao?Lin Xiong
    Chao Zheng
    Ke Gong
    Sheng Yang
    Xiao?Jing Liu
    Min Gao
    Xiang?Yang Wen
    Ya?Qing liu
    Yan?Bing Xu
    Xiao?Yun Zhao
    Jia?Cong Liu
    Fan Zhang
    Hong Lu
    Nuclear Science and Techniques, 2024, 35 (02) : 59 - 71
  • [25] Characterization of a novel proton-CT scanner based on Silicon and LaBr3(Ce) detectors
    Nacher, E.
    Briz, J. A.
    Nerio, A. N.
    Perea, A.
    Tavora, V. G.
    Tengblad, O.
    Ciemala, M.
    Cieplicka-Orynczak, N.
    Maj, A.
    Mazurek, K.
    Olko, P.
    Zieblinski, M.
    Borge, M. J. G.
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (05):
  • [26] LaBr3:: Ce scintillation camera
    Pani, R.
    Cinti, M. N.
    Pellegrini, R.
    De Notaristefani, F.
    Bennati, P.
    Betti, M.
    Trotta, G.
    Mattioli, M.
    Garibaldi, F.
    Orsolini Cencelli, V
    Moschini, G.
    Navarria, F.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2061 - 2065
  • [27] Characterization of large volume 3.5" x 8" LaBr3:Ce detectors
    Giaz, A.
    Pellegri, L.
    Riboldi, S.
    Camera, F.
    Blasi, N.
    Boiano, C.
    Bracco, A.
    Brambilla, S.
    Ceruti, S.
    Coelli, S.
    Crespi, F. C. L.
    Csatlos, M.
    Frega, S.
    Gulyas, J.
    Krasznahorkay, A.
    Lodetti, S.
    Million, B.
    Owens, A.
    Quarati, F.
    Stuhl, L.
    Wieland, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 910 - 921
  • [28] High count rate γ-ray spectroscopy with LaBr3:Ce scintillation detectors
    Loeher, B.
    Savran, D.
    Fiori, E.
    Miklavec, M.
    Pietralla, N.
    Vencelj, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 686 : 1 - 6
  • [29] A phoswich composed of CsI:Na and LaBr3:Ce To improve the low energy response of LaBr3:Ce
    Gao, X.
    He, Y. J.
    Chen, Y. B.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (3-4): : 344 - 347
  • [30] Comparison of CeBr3 with LaBr3:Ce, LaCl3:Ce, and NaI:Tl Detectors
    Guss, Paul
    Reed, Michael
    Yuan, Ding
    Cutler, Matthew
    Contreras, Chris
    Beller, Denis
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII, 2010, 7805