Non-Enzymatic CO3O4 Nanostructure-Based Electrochemical Sensor for H2O2 Detection

被引:1
|
作者
Mizers, V. [1 ]
Gerbreders, V. [1 ]
Krasovska, M. [1 ]
Sledevskis, E. [1 ]
Mihailova, I. [1 ]
Ogurcovs, A. [1 ,2 ]
Bulanovs, A. [1 ]
Gerbreders, A. [2 ]
机构
[1] Daugavpils Univ, Inst Life Sci & Technol, G Liberts Innovat Microscopy Ctr, Dept Technol, 1a Parades Str, LV-5401 Daugavpils, Latvia
[2] Univ Latvia, Inst Solid State Phys, 8 Kengaraga Str, LV-1063 Riga, Latvia
关键词
Electrochemical sensor; cobalt oxide; cyclic voltammetry; hydrogen peroxide; nanostructures; GRAPHENE OXIDE NANOCOMPOSITE; HYDROGEN-PEROXIDE H2O2; NANOPARTICLES; WATER; PERFORMANCE; MORPHOLOGY; ELECTRODE; SYSTEM; AU;
D O I
10.2478/lpts-2023-0037
中图分类号
O59 [应用物理学];
学科分类号
摘要
This article describes the synthesis of nanostructured cobalt oxide on iron wires and its application for the detection of hydrogen peroxide as working electrode for non-enzymatic electrochemical sensor. Cobalt oxide was obtained by the hydrothermal synthesis method using chloride and acetate anions. The resulting nanostructured coating obtained from the chloride precursor is a uniform homogeneous porous network of long nanofibers assembled into regular honey & scy;omb-like formations. In the case of an acetate precursor, instead of nanofibers, petal-like nanostructures assembled into honeycomb agglomerates are observed. The structure, surface, and composition of the obtained samples were studied using field-emission scanning electron microscopy along with energy-dispersive spectroscopy and X-ray diffractometry.The resultant nanostructured specimens were utilized to detect H2O2 electrochemically through cyclic voltammetry, differential pulse voltammetry, and i-t measurements. A comparative research has demonstrated that the nanostructures produced from the chloride precursor exhibit greater sensitivity to H2O2 and have a more appropriate morphology for designing a nanostructured sensor. A substantial linear correlation between the peak current and H2O2 concentration within the 20 to 1300 mu M range was established. The Co3O(4) electrode obtained exhibits a sensitivity of 505.11 mu A<middle dot>mM(-1), and the electroactive surface area is calculated to be 4.684 cm(2). Assuming a signal-to-noise ratio of 3, the calculated limit of detection is 1.05 mu M. According to the interference study, the prevalent interfering agents, such as ascorbic acid, uric acid, NaCl, and glucose, do not influence the electrochemical reaction. The obtained results confirm that this sensor is suitable for working with complex analytes.The actual sample assessment demonstrated a recovery rate exceeding 95 %.
引用
收藏
页码:63 / 84
页数:22
相关论文
共 50 条
  • [41] Fabrication of hollow CuO/PANI hybrid nanofibers for non-enzymatic electrochemical detection of H2O2 and glucose
    Liu, Tianjiao
    Guo, Yuqi
    Zhang, Zhenfang
    Miao, Zhicong
    Zhang, Xiaoyuan
    Su, Zhiqiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 370 - 376
  • [42] High-performance non-enzymatic glucose sensor based on Co3O4/rGO nanohybrid
    Ling-Yun Xiong
    You-Joong Kim
    Won-Cheol Seo
    Han-Kyu Lee
    Woo-Chul Yang
    Wan-Feng Xie
    Rare Metals, 2023, 42 (09) : 3046 - 3053
  • [43] High-performance non-enzymatic glucose sensor based on Co3O4/rGO nanohybrid
    Ling-Yun Xiong
    You-Joong Kim
    Won-Cheol Seo
    Han-Kyu Lee
    Woo-Chul Yang
    Wan-Feng Xie
    Rare Metals, 2023, 42 : 3046 - 3053
  • [44] High-performance non-enzymatic glucose sensor based on Co3O4/rGO nanohybrid
    Xiong, Ling-Yun
    Kim, You-Joong
    Seo, Won-Cheol
    Lee, Han-Kyu
    Yang, Woo-Chul
    Xie, Wan-Feng
    RARE METALS, 2023, 42 (09) : 3046 - 3053
  • [45] Electrocatalytic oxidation and reduction of H2O2 on vertically aligned Co3O4 nanowalls electrode: Toward H2O2 detection
    Jia, Wenzhao
    Guo, Min
    Zheng, Zhe
    Yu, Ting
    Rodriguez, Edgar G.
    Wang, Ying
    Lei, Yu.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 625 (01) : 27 - 32
  • [46] Manganese oxide ultrathin nanosheets sensors for non-enzymatic detection of H2O2
    Zhang, Ping
    Guo, Di
    Li, Qiuhong
    MATERIALS LETTERS, 2014, 125 : 202 - 205
  • [47] THP as a sensor for the electrochemical detection of H2O2
    Failla, Mariacristina
    Ferlazzo, Angelo
    Abbate, Vincenzo
    Neri, Giovanni
    Saccullo, Erika
    Gulino, Antonino
    Rescifina, Antonio
    Patamia, Vincenzo
    Floresta, Giuseppe
    BIOORGANIC CHEMISTRY, 2024, 152
  • [48] Non-enzymatic approach of H2O2 and glucose sensing using NiO-MoS2-derived electrochemical sensor
    Medhi, Ankush
    Giri, Manas Kumar
    Mohanta, D.
    BULLETIN OF MATERIALS SCIENCE, 2024, 47 (04)
  • [49] Hollow Spherical NiCo2O4 and Gold Nanoparticle Composite for Electrochemical Non-Enzymatic Glucose and H2O2 Sensing
    Feng, Li
    Xu, Yan
    Deng, Wanting
    Wang, Yadong
    Min, Xiaoqin
    Lin, Xiaoyun
    Ni, Yongnian
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (12)
  • [50] A disposable non-enzymatic dual sensor for simultaneous amperometric determination of NADH and H2O2
    Eda Kıymaz Onat
    Melike Bilgi Kamaç
    Merve Yılmaz
    Journal of Applied Electrochemistry, 2023, 53 : 2213 - 2227