Non-Enzymatic CO3O4 Nanostructure-Based Electrochemical Sensor for H2O2 Detection

被引:1
|
作者
Mizers, V. [1 ]
Gerbreders, V. [1 ]
Krasovska, M. [1 ]
Sledevskis, E. [1 ]
Mihailova, I. [1 ]
Ogurcovs, A. [1 ,2 ]
Bulanovs, A. [1 ]
Gerbreders, A. [2 ]
机构
[1] Daugavpils Univ, Inst Life Sci & Technol, G Liberts Innovat Microscopy Ctr, Dept Technol, 1a Parades Str, LV-5401 Daugavpils, Latvia
[2] Univ Latvia, Inst Solid State Phys, 8 Kengaraga Str, LV-1063 Riga, Latvia
关键词
Electrochemical sensor; cobalt oxide; cyclic voltammetry; hydrogen peroxide; nanostructures; GRAPHENE OXIDE NANOCOMPOSITE; HYDROGEN-PEROXIDE H2O2; NANOPARTICLES; WATER; PERFORMANCE; MORPHOLOGY; ELECTRODE; SYSTEM; AU;
D O I
10.2478/lpts-2023-0037
中图分类号
O59 [应用物理学];
学科分类号
摘要
This article describes the synthesis of nanostructured cobalt oxide on iron wires and its application for the detection of hydrogen peroxide as working electrode for non-enzymatic electrochemical sensor. Cobalt oxide was obtained by the hydrothermal synthesis method using chloride and acetate anions. The resulting nanostructured coating obtained from the chloride precursor is a uniform homogeneous porous network of long nanofibers assembled into regular honey & scy;omb-like formations. In the case of an acetate precursor, instead of nanofibers, petal-like nanostructures assembled into honeycomb agglomerates are observed. The structure, surface, and composition of the obtained samples were studied using field-emission scanning electron microscopy along with energy-dispersive spectroscopy and X-ray diffractometry.The resultant nanostructured specimens were utilized to detect H2O2 electrochemically through cyclic voltammetry, differential pulse voltammetry, and i-t measurements. A comparative research has demonstrated that the nanostructures produced from the chloride precursor exhibit greater sensitivity to H2O2 and have a more appropriate morphology for designing a nanostructured sensor. A substantial linear correlation between the peak current and H2O2 concentration within the 20 to 1300 mu M range was established. The Co3O(4) electrode obtained exhibits a sensitivity of 505.11 mu A<middle dot>mM(-1), and the electroactive surface area is calculated to be 4.684 cm(2). Assuming a signal-to-noise ratio of 3, the calculated limit of detection is 1.05 mu M. According to the interference study, the prevalent interfering agents, such as ascorbic acid, uric acid, NaCl, and glucose, do not influence the electrochemical reaction. The obtained results confirm that this sensor is suitable for working with complex analytes.The actual sample assessment demonstrated a recovery rate exceeding 95 %.
引用
收藏
页码:63 / 84
页数:22
相关论文
共 50 条
  • [1] Design and Synthesis of Multilevel Structured Co3O4 Double-shell Dodecahedron as Non-enzymatic Electrochemical Sensor for H2O2 Detection
    Zhang, Zhixuan
    Liang, Zhiqi
    Huang, Meishi
    Shen, Dong
    Hu, Zufei
    Yang, Yang
    Wu, Zhouling
    Electrochemistry, 2024, 92 (11)
  • [2] Non-enzymatic electrochemical sensors for the detection of H2O2 based on Mn3O4 octahedron submicrostructures
    Wang, Liang
    Wu, Kong-Lin
    Jiang, Bin-Bin
    Zhang, Zai-Xian
    Li, Xiang-Zi
    Zhang, Bei
    Lv, Ju
    Suan, Jian
    Dong, Chao
    MICRO & NANO LETTERS, 2014, 9 (10) : 736 - 740
  • [3] MWCNT Based Non-Enzymatic H2O2 Sensor: Influence of Amine Functionalization on the Electrochemical H2O2 Sensing
    Revathi, C.
    Rajavel, K.
    Saranya, M.
    Kumar, R. T. Rajendra
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (13) : B627 - B632
  • [4] Non-enzymatic Fructose Sensor Based on Co3O4 Thin Film
    Gota, Tatenda
    Chowdhury, Mahabubur
    Ojumu, Tunde
    ELECTROANALYSIS, 2017, 29 (12) : 2855 - 2862
  • [5] Non-enzymatic hydrogen peroxide sensor based on Co3O4 nanocubes
    Cao, Guang Sheng
    Wang, Lei
    Yuan, Pengfei
    Gao, Chao
    Liu, Xiaojuan
    Li, Tong
    Li, Tianmin
    BULLETIN OF MATERIALS SCIENCE, 2014, 37 (06) : 1369 - 1373
  • [6] Non-enzymatic hydrogen peroxide sensor based on Co3O4 nanocubes
    Guang Sheng Cao
    Lei Wang
    Pengfei Yuan
    Chao Gao
    Xiaojuan Liu
    Tong Li
    Tianmin Li
    Bulletin of Materials Science, 2014, 37 : 1369 - 1373
  • [7] Non-enzymatic electrochemical detection of H2O2 using Ni (OH)2 nanoparticles
    Medhi, Ankush
    Giri, Manas Kumar
    Mohanta, D.
    MATERIALS TODAY-PROCEEDINGS, 2022, 68 : 262 - 267
  • [8] Electrophoretic Deposition of Co3O4 Particles/Reduced Graphene Oxide Composites for Efficient Non-Enzymatic H2O2 Sensing
    Wang, Qian
    Wang, Yuzhe
    Xiao, Guiyong
    Zhu, Xinde
    MATERIALS, 2023, 16 (03)
  • [9] Advances in Non-Enzymatic electrochemical materials for H2O2 sensing
    Liu, Jinzheng
    Li, Mingzhu
    Liu, Wendong
    Hao, Zhe
    Zhang, Fanghua
    Pang, Huajie
    Zhang, Ruizhong
    Zhang, Libing
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 954
  • [10] Functional Co3O4 nanostructure-based electrochemical sensor for direct determination of ascorbic acid in pharmaceutical samples
    Khand, Nadir H.
    Palabiyik, Ismail M.
    Buledi, Jamil A.
    Ameen, Sidra
    Memon, Almas F.
    Ghumro, Tania
    Solangi, Amber R.
    JOURNAL OF NANOSTRUCTURE IN CHEMISTRY, 2021, 11 (03) : 455 - 468