Pinch point variation in the gas cooler of the CO2 heat pump water heater: An experimental and simulation comparative study

被引:2
|
作者
Cui, Qi [1 ]
Gao, Enyuan [1 ,3 ,4 ]
Wei, Dianhang [1 ]
Qi, Pengcheng [5 ]
Zhang, Xiaosong [1 ,2 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Minist Educ, Engn Res Ctr BEEE, Beijing, Peoples R China
[3] Hua Shang Int Engn Co Ltd, Beijing 100069, Peoples R China
[4] Chinese Assoc Refrigerat, Beijing 100142, Peoples R China
[5] Jiangsu JTL Solar Nucl Power Technol Co Ltd, Wuxi 214000, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon dioxide heat pump; Gas cooler; Pinch point; Experimental investigation; DISCHARGE PRESSURE; PERFORMANCE; ADSORPTION; COMPOSITE;
D O I
10.1016/j.tsep.2023.101959
中图分类号
O414.1 [热力学];
学科分类号
摘要
The carbon dioxide heat pump operation is strongly impacted by the presence of the pinch point within the gas cooler. The existing findings regarding the pinch point need to be verified due to the deficiencies of the simu-lation method. Given this, an experimental and simulation comparative study is performed. The pinch point variation characteristics and its connection with the heat pump operation are elucidated. The limitations and accuracy of the simulation model are revealed. The location and number of the pinch point are at most four scenarios. One locates at inside. Two locate at inside and cold end, respectively. One locates at cold end. One locates at hot end. The hot end pinch point is difficult to occur for actual heat pump operating conditions. As the carbon dioxide pressure rises, the pinch point temperature difference first grows slightly and then drops. The experiments demonstrated that the actual best operation of the carbon dioxide heat pump corresponds to one inside pinch point rather than two. The simulation model cannot reproduce this phenomenon well. The accuracy of the simulation model can be greatly improved in case the pinch point location is known, and it is acceptable from the perspective of meeting the engineering permissible error. This study may contribute to a better un-derstanding of the pinch point variation. Moreover, it may play a reference role in the building and optimization of the gas cooler model.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Pinch point characteristics and performance evaluation of CO2 heat pump water heater under variable working conditions
    Cui, Qi
    Wang, Chen
    Gao, Enyuan
    Zhang, Xiaosong
    APPLIED THERMAL ENGINEERING, 2022, 207
  • [12] Distribution of heat transfer pinch point of gas cooler in CO2 inverse-cycle
    Tu, Daixing
    Zhao, Li
    Wang, Jianli
    Wang, Xiaodong
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2009, 45 (09): : 307 - 311
  • [13] Dynamic model and experimental validation for a gas cooler of a CO2 heat pump for heating residential water
    de Oliveira, Raphael Nunes
    Faria, Ralney Nogueira
    Antonanzas-Torres, Fernando
    Machado, Luiz
    Nassar Koury, Ricardo Nicolau
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (01) : 30 - 40
  • [14] Optimal discharge pressure in transcritical CO2 heat pump water heater with internal heat exchanger based on pinch point analysis
    Ye, Zuliang
    Wang, Yikai
    Song, Yulong
    Yin, Xiang
    Cao, Feng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 118 : 12 - 20
  • [15] Study of CO2 transcritical cycle heat pump water heater
    Li, Minxia
    Gong, Wenjin
    Ma, Yitai
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1544 - 1550
  • [16] Experimental study and optimal control strategy of a transcritical CO2 heat pump water heater
    Ye, Zuliang
    Wang, Yikai
    Cao, Feng
    INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS 2019, 2019, 604
  • [18] Experimental study on two types of transcritical CO2 heat pump water heater system
    Chen, Qi
    Tong, Yang
    Li, Mao
    Zhu, Zhijiang
    Tang, Liming
    Chen, Guangming
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2013, 34 (11): : 1903 - 1909
  • [19] Study of multi-twisted-tube gas cooler for CO2 heat pump water heaters
    Yang Yingying
    Li Minxia
    Wang Kaiyang
    Ma Yitai
    APPLIED THERMAL ENGINEERING, 2016, 102 : 204 - 212
  • [20] EXPERIMENTAL EVALUATION OF A WATER SOURCE CO2 HEAT PUMP INCORPORATING NOVEL GAS-COOLER CONFIGURATION
    Murray, Portia
    Harrison, Stephen
    Johnson, Gary
    Stinson, Ben
    PROCEEDINGS OF THE ASME 8TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2014, VOL 2, 2014,