Parametric investigation of flexural performance of concrete prisms retrofitted with near-surface mounted FRP bars

被引:5
|
作者
Al-Zu'bi, Mohammad [1 ]
Fan, Mizi [1 ]
Anguilano, Lorna [2 ]
机构
[1] Brunel Univ London, Dept Civil & Environm Engn, Coll Engn Design & Phys Sci, Uxbridge UB8 3PH, England
[2] Brunel Univ London, Coll Engn Design & Phys Sci, Expt Tech Ctr, Uxbridge UB8 3PH, England
来源
关键词
Concrete members; Flexural retrofitting; NSM-FRP technique; Parametric study; NSM CFRP STRIPS; RC BEAMS; BEHAVIOR; STATE; RODS; BOND;
D O I
10.1016/j.jcomc.2023.100421
中图分类号
TB33 [复合材料];
学科分类号
摘要
This study investigates the impact of flexural retrofitting on the load-bearing capacity, ductility and failure modes of concrete prisms using the NSM-FRP technique, considering four design parameters. Some specimens were retrofitted with NE only, while others incorporated FRP (i.e. CFRP, GFRP or BFRP) reinforcement bars alongside NE to assess the influence of presence of FRP reinforcement on the specimens' performance. The study also examines changing the position of GFRP reinforcement bars (cantered or along the groove's edge), using different numbers of CFRP bars (one, two or three) and considering three groove dimensions (8 x 8 mm2, 10 x 10 mm2 and 12 x 12 mm2). Results showed that NE-only retrofitting increased the capacity by about 38 % compared to the non-retrofitted specimens, with negligible impact on ductility. Introducing FRP reinforcement led to an approximately twofold increase in capacity and ductility compared to NE-only retrofitting. Placing GFRP reinforcement bars along the edge of the groove minimally affected the capacity but reduced ductility by about 24 %. Increasing the number of CFRP bars from one to three significantly improved capacity and ductility but increased the risk of debonding failures. Using larger groove sizes (10 x 10 mm2) enhanced capacity of the CFRP-retrofitted specimens, slightly reduced GFRP-retrofitted concrete capacity and improved ductility for both. The 12 x 12 mm2 groove size reduced capacity but increased ductility. The 10 x 10 mm2 groove size effectively prevented debonding failures observed with other sizes.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Flexural behaviour of concrete beams strengthened with near surface mounted fibre reinforced polymer bars
    Soliman, Shehab M.
    El-Salakawy, Ehab
    Benmokrane, Brahim
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2010, 37 (10) : 1371 - 1382
  • [42] Fire behavior of concrete T-beams strengthened with near-surface mounted FRP reinforcement
    Yu, B.
    Kodur, V. K. R.
    ENGINEERING STRUCTURES, 2014, 80 : 350 - 361
  • [43] Research on Bending Resistance of Reinforced Concrete Beam Strengthened with Near-surface Mounted FRP Bar
    Xu Yongfeng
    Zhang Liqun
    Wang Hailong
    CIVIL ENGINEERING IN CHINA - CURRENT PRACTICE AND RESEARCH REPORT: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING, 2011, : 382 - 385
  • [44] A state-of-the-art review: Near-surface mounted FRP composites for reinforced concrete structures
    Al-Saadi, Nihad Tareq Khshain
    Mohammed, Alyaa
    Al-Mahaidi, Riadh
    Sanjayan, Jay
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 209 : 748 - 769
  • [45] A modified pull-out test for bond of near-surface mounted FRP rods in concrete
    De Lorenzis, L
    Rizzo, A
    La Tegola, A
    COMPOSITES PART B-ENGINEERING, 2002, 33 (08) : 589 - 603
  • [46] Reinforced Concrete Beams Strengthened in Flexure with Near-Surface Mounted 7075 Aluminum Alloy Bars
    Xing, Guo-Hua
    Chen, Xu
    Huang, Jiao
    Zhang, Yu
    Ozbulut, Osman E.
    Chang, Zhao-Qun
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (01)
  • [47] Experimental study on the flexural behavior of concrete beams strengthened with near-surface mounted CFRP laminates
    Huang, Li
    Li, Xian
    Zhang, Hua
    CIVIL ENGINEERING AND URBAN PLANNING IV, 2016, : 753 - 756
  • [48] Performance of near surface mounted glass fiber reinforced polymer bars in concrete
    El-Gamal, Sherif
    Al-Salloum, Yousef
    Alsayed, Saleh
    Aqel, Mohammad
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2012, 31 (22) : 1501 - 1515
  • [49] Anchorage length of near-surface mounted fiber-reinforced polymer bars for concrete strengthening - Experimental investigation and numerical modeling
    De Lorenzis, L
    Lundgren, K
    Rizzo, A
    ACI STRUCTURAL JOURNAL, 2004, 101 (02) : 269 - 278
  • [50] Flexural strengthening of reinforced concrete beams using prestressed, near-surface-mounted CFRP bars
    El-Hacha, Raafat
    Gaafar, Mohamed
    PCI JOURNAL, 2011, : 134 - 151