Study on the influencing factors on indoor PM2.5 of office buildings in beijing based on statistical and machine learning methods

被引:8
|
作者
Li, Zehao [1 ]
Di, Zhenzhen [1 ]
Chang, Miao [1 ]
Zheng, Ji [1 ]
Tanaka, Toshio [2 ]
Kuroi, Kiyoshi [2 ]
机构
[1] Tsinghua Univ, Sch Environm, Beijing 100084, Peoples R China
[2] Daikin Ind Ltd, Osaka 5308323, Japan
来源
关键词
Indoor air quality; PM2; 5; Contribution; Office buildings; IoT devices; WINDOW-OPENING BEHAVIOR; OUTDOOR AIR-QUALITY; PARTICULATE MATTER; COMMERCIAL BUILDINGS; EXPOSURE; PARTICLES; POLLUTION; IMPACT; PENETRATION; OCCUPANTS;
D O I
10.1016/j.jobe.2022.105240
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To investigate the interactions and contributions of the influencing factors on indoor PM2.5, indoor monitoring data (including PM2.5, CO2, temperature, humidity, and window states) at six office buildings sites in Beijing and outdoor air quality and meteorological data at nearby national sites were collected and analyzed. Seemingly unrelated estimation (SUEST) tests and decision tree models were conducted, and results indicated that opening windows increased the infiltration factor and decreased the impact of indoor sources, while it may not be effective enough to remove indoor particles in some conditions. Besides, the influence of factors is nonlinear, and the correlations between factors make the form of cross-terms complex. The contribution of outdoor PM2.5 and periodic factors adds up to 68.43 & PLUSMN; 6.07%, and the main differences among the results are reflected in the allocation of these factors. Outdoor PM2.5 is shown to play the most important role in the variation of indoor PM2.5 in most office spaces (49.55 & PLUSMN; 16.87%). Periodic factors and personnel activities are significant (16.34 & PLUSMN; 10.02%) and strong personnel activities seemed to increase the impact of periodic factors on indoor PM2.5, while the impact of window states is limited (3.41 & PLUSMN; 2.63%). The contribution of outdoor meteorology and indoor environment is 11.89 & PLUSMN; 2.63% and 16.26 & PLUSMN; 4.40% respectively. The influence of wind direction is stronger than that of wind speed, and temperature and humidity were shown to be equally important in the variation of indoor PM2.5. The data and results can provide suggestions for indoor air quality management, and the methods proposed in this study can be used to evaluate the impact of other factors on indoor air quality based on long-term monitoring data.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Beijing PM2.5 Influencing Factors Analysis Based on GAM
    Tao, Guiping
    Chen, Hongmei
    Li, Wenjun
    2020 IEEE/WIC/ACM INTERNATIONAL JOINT CONFERENCE ON WEB INTELLIGENCE AND INTELLIGENT AGENT TECHNOLOGY (WI-IAT 2020), 2020, : 916 - 921
  • [2] Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing
    Yang, Yibing
    Liu, Liu
    Xu, Chunyu
    Li, Na
    Liu, Zhe
    Wang, Qin
    Xu, Dongqun
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (04)
  • [3] The effects of ventilation and filtration on indoor PM2.5 in office buildings in four countries
    Jones, Emily R.
    Laurent, Jose Guillermo Cedeno
    Young, Anna S.
    MacNaughton, Piers
    Coull, Brent A.
    Spengler, John D.
    Allen, Joseph G.
    BUILDING AND ENVIRONMENT, 2021, 200
  • [4] Spatiotemporal variations and influencing factors of PM2.5 concentrations in Beijing, China
    Zhang, Licheng
    An, Ji
    Liu, Mengyang
    Li, Zhiwei
    Liu, Yue
    Tao, Lixin
    Liu, Xiangtong
    Zhang, Feng
    Zheng, Deqiang
    Gao, Qi
    Guo, Xiuhua
    Luo, Yanxia
    ENVIRONMENTAL POLLUTION, 2020, 262
  • [5] A study on the impact of meteorological and emission factors on PM2.5 concentrations based on machine learning
    Zhao, Chenxu
    Lin, Zejian
    Yang, Leifeng
    Jiang, Mengmeng
    Qiu, Zhubing
    Wang, Siyu
    Gu, Yu
    Ye, Wei
    Pan, Yusuo
    Zhang, Yong
    Wang, Tianxin
    Jia, Yong
    Chen, Zhihang
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2025, 376
  • [6] Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing
    Deng, Gaofeng
    Li, Zenghe
    Wang, Zhichao
    Gao, Jubao
    Xu, Zhaowei
    Li, Jiandong
    Wang, Zhiyong
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (01) : 60 - 68
  • [7] Analysis of the Gridded Influencing Factors of the PM2.5 Concentration in Sichuan Province Based on a Stacked Machine Learning Model
    Wu, Yuhong
    Du, Ning
    Wang, Li
    Cai, Hong
    Zhou, Bin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2023, 17 (01)
  • [8] Analysis of the Gridded Influencing Factors of the PM2.5 Concentration in Sichuan Province Based on a Stacked Machine Learning Model
    Yuhong Wu
    Ning Du
    Li Wang
    Hong Cai
    Bin Zhou
    International Journal of Environmental Research, 2023, 17
  • [9] Research on Factors Influencing Indoor PM2.5 Concentration in Curling Venues Based on CFD Simulation
    Du, Xiaohui
    Li, Jiaxin
    Tang, Ziying
    Hu, Shijing
    APPLIED SCIENCES-BASEL, 2024, 14 (08):
  • [10] Relationship between Outdoor and Indoor PM10,PM2.5 and PM1 in Apartment and Office Buildings
    文远高
    连之伟
    叶晓江
    兰丽
    JournalofDonghuaUniversity(EnglishEdition), 2008, (03) : 334 - 339