Dosimetric comparison of three-dimensional (3D), intensity-modulated radiotherapy (IMRT) and hybrid IMRT for left-sided postmastectomy radiation therapy (PMRT)

被引:0
|
作者
Thongthanom, Siwika [1 ,2 ]
Nobnop, Wannapha [3 ,4 ]
机构
[1] Chiang Mai Univ, Fac Med, Grad Sch, Med Phys Program, Chiang Mai, Thailand
[2] Samutsakhon Hosp, Dept Radiol, Samutsakhon, Thailand
[3] Chiang Mai Univ, Fac Med, Div Radiat Oncol, Chiang Mai, Thailand
[4] Chiang Mai Univ, Fac Med, Northern Thai Res Grp Radiat Oncol NTRG RO, Chiang Mai, Thailand
关键词
dosimetric; hybrid IMRT; IMRT; postmastectomy; treatment time; BREAST-CANCER; 3D-CRT;
D O I
10.1017/S1460396923000250
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:This study aimed to determine the suitable breast treatment technique for a small facility's hospital with limited staff and equipment resources. The benefits and drawbacks of each technique should be considered to guide radiation oncologists choose the appropriate treatment option for postmastectomy radiation therapy (PMRT) patients. Methods and Materials:This study included the computed tomography images of 15 patients who received left-sided PMRT. The patient's characteristics were classified into two groups: 1. irradiation of only the chest wall (CW) and 2. CW lymph nodes plus supraclavicular lymph nodes (SPCs). All 15 PMRT patients were generated in 4 treatment techniques including 3DCRT, field-in-field (FiF), intensity-modulated radiotherapy (IMRT) and hybrid (3DCRT + IMRT). Each treatment technique's dosimetric parameters and treatment time were compared. Result:All four treatment plans met the acceptable criteria. The IMRT plans achieved the highest plan quality scores for two groups of PMRT patients but require the longest treatment time, whereas the 3DCRT and FiF plans demonstrated superiority for organ at risk (OAR) sparing and required the shortest treatment time when compared with the IMRT and hybrid plans. Conclusion:The IMRT plan had the highest plan quality but required the most time to treat. Treatment times are critical in facilities with limited resources. As a result, the FiF plan was found to be a suitable technique for both CW-only and CW plus SPC irradiation due to its short treatment time and high plan quality scores for OAR dose sparing.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Dosimetric Comparison of Intensity Modulated Radiation Therapy (IMRT), 3D Conformal Proton Therapy and Intensity Modulated Proton Therapy (IMPT) for Metastatic Brain Cancer
    Sullivan, M.
    Ahmad, S.
    Jin, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [22] The dosimetric effects of tissue heterogeneities in Intensity-modulated Radiation Therapy (IMRT) of the head and neck
    Al-Hallaq, H
    Reft, C
    Haraf, D
    Roeske, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1315 - 1315
  • [23] The dosimetric effects of tissue heterogeneities in intensity-modulated radiation therapy (IMRT) of the head and neck
    Al-Hallaq, HA
    Reft, CS
    Roeske, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05): : 1145 - 1156
  • [24] Intensity-modulated radiation therapy (IMRT) vs. 3D conformal radiotherapy (3DCRT) in locally advanced rectal cancer (LARC): dosimetric comparison and clinical implications
    Arbea, Leire
    Isaac Ramos, Luis
    Martinez-Monge, Rafael
    Moreno, Marta
    Aristu, Javier
    RADIATION ONCOLOGY, 2010, 5
  • [25] Intensity-modulated radiation therapy (IMRT) vs. 3D conformal radiotherapy (3DCRT) in locally advanced rectal cancer (LARC): dosimetric comparison and clinical implications
    Leire Arbea
    Luis Isaac Ramos
    Rafael Martínez-Monge
    Marta Moreno
    Javier Aristu
    Radiation Oncology, 5
  • [26] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [27] Dosimetric comparison of standard three-dimensional conformal radiotherapy followed by intensity-modulated radiotherapy boost schedule (sequential IMRT plan) with simultaneous integrated boost-IMRT (SIB IMRT) treatment plan in patients with localized carcinoma prostate
    Bansal, A.
    Kapoor, R.
    Singh, S. K.
    Kumar, N.
    Oinam, A. S.
    Sharma, S. C.
    INDIAN JOURNAL OF UROLOGY, 2012, 28 (03) : 300 - 306
  • [28] Can all centers plan intensity-modulated radiotherapy (IMRT) effectively? An external audit of dosimetric comparisons between three-dimensional conformal radiotherapy and IMRT for adjuvant chemoradiation for gastric cancer
    Chung, Hans T.
    Lee, Brian
    Park, Eileen
    Lu, Jiade J.
    Xia, Ping
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1167 - 1174
  • [29] A Comprehensive Dosimetric Study of Pancreatic Cancer Treatment Using Three Dimensional (3D) Conformal Radiation Therapy, Intensity-Modulated Radiation Therapy (IMRT), Volumetric Modulated Radiation Therapy (VMAT), Passive Scattering and Modulated Scanning Proton Therapy (PT)
    Ding, X.
    Avery, S.
    Kassaee, A.
    Metz, J.
    Prionas, V.
    Huang, L.
    McQuiggan, S.
    Butterwick, I.
    Martinsen, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] Dosimetric comparison of sequential intensity-modulated radiation therapy (IMRT) and simultaneous integrated boost IMRT for lymph node-positive cervical cancer
    Mohanty, Samarpita
    Hajare, Raghavendra
    Gurram, Lavanya
    Aravindakshan, Dheera
    Midha, Vanisha
    Chopra, Supriya
    Mahantshetty, Umesh
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22