Dosimetric comparison of three-dimensional (3D), intensity-modulated radiotherapy (IMRT) and hybrid IMRT for left-sided postmastectomy radiation therapy (PMRT)

被引:0
|
作者
Thongthanom, Siwika [1 ,2 ]
Nobnop, Wannapha [3 ,4 ]
机构
[1] Chiang Mai Univ, Fac Med, Grad Sch, Med Phys Program, Chiang Mai, Thailand
[2] Samutsakhon Hosp, Dept Radiol, Samutsakhon, Thailand
[3] Chiang Mai Univ, Fac Med, Div Radiat Oncol, Chiang Mai, Thailand
[4] Chiang Mai Univ, Fac Med, Northern Thai Res Grp Radiat Oncol NTRG RO, Chiang Mai, Thailand
关键词
dosimetric; hybrid IMRT; IMRT; postmastectomy; treatment time; BREAST-CANCER; 3D-CRT;
D O I
10.1017/S1460396923000250
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:This study aimed to determine the suitable breast treatment technique for a small facility's hospital with limited staff and equipment resources. The benefits and drawbacks of each technique should be considered to guide radiation oncologists choose the appropriate treatment option for postmastectomy radiation therapy (PMRT) patients. Methods and Materials:This study included the computed tomography images of 15 patients who received left-sided PMRT. The patient's characteristics were classified into two groups: 1. irradiation of only the chest wall (CW) and 2. CW lymph nodes plus supraclavicular lymph nodes (SPCs). All 15 PMRT patients were generated in 4 treatment techniques including 3DCRT, field-in-field (FiF), intensity-modulated radiotherapy (IMRT) and hybrid (3DCRT + IMRT). Each treatment technique's dosimetric parameters and treatment time were compared. Result:All four treatment plans met the acceptable criteria. The IMRT plans achieved the highest plan quality scores for two groups of PMRT patients but require the longest treatment time, whereas the 3DCRT and FiF plans demonstrated superiority for organ at risk (OAR) sparing and required the shortest treatment time when compared with the IMRT and hybrid plans. Conclusion:The IMRT plan had the highest plan quality but required the most time to treat. Treatment times are critical in facilities with limited resources. As a result, the FiF plan was found to be a suitable technique for both CW-only and CW plus SPC irradiation due to its short treatment time and high plan quality scores for OAR dose sparing.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy (3D-CRT) and Intensity Modulated Radiotherapy Techniques (IMRT) with Radiotherapy Dose Simulations For Left-Sided Mastectomy Patients
    Aras, Serhat
    Ikizceli, Turkan
    Aktan, Meryem
    EUROPEAN JOURNAL OF BREAST HEALTH, 2019, 15 (02) : 85 - 89
  • [2] Dosimetric comparison of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left-sided chest wall and lymphatic irradiation
    Kivanc, Huseyin
    Gultekin, Melis
    Gurkaynak, Murat
    Ozyigit, Gokhan
    Yildiz, Ferah
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (12): : 36 - 44
  • [3] Dosimetric Comparison between 3D-Conformal Radiotherapy and Intensity-modulated Radiation Therapy (IMRT) in Stereotactic Body Radiotherapy
    Cao, M.
    Das, I. J.
    Hutchins, K. M.
    Ewing, M. M.
    Fakiris, A. J.
    DesRosiers, C. M.
    Johnstone, P. A. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S694 - S694
  • [4] Preoperative chemoradiotherapy for locally advanced rectal adenocarcinoma: A dosimetric comparison of intensity-modulated radiation therapy (IMRT) with three-dimensional conformal radiotherapy (3D-CRT).
    Tao, C. T.
    Scala, L. M.
    Gee, H.
    Lim, D.
    Padilla, B.
    Rounsaville, M. C.
    Lee, J. W.
    Abendroth, R. E.
    JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (04)
  • [5] Hybrid intensity-modulated radiation therapy (IMRT) simultaneous integrated boost (SIB) technique versus three-dimensional (3D) conformal radiotherapy with SIB for breast radiotherapy: a planning comparison
    Smith, Shayne K.
    Estoesta, Reuben P.
    Kader, Jaraad A.
    Martin, Darren
    Claridge-Mackonis, Elizabeth R.
    Toohey, Joanne M.
    Carroll, Susan L.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2016, 15 (02) : 131 - 142
  • [6] Dosimetric comparison between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of different stages of nasopharyngeal carcinoma
    Ibrahim, Mohamed S.
    Attalla, Ehab M.
    El Naggar, Mostafa
    Elshemey, Wael M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 46 - 51
  • [7] Radiation Dose to Critical Cardiac Structures from Three-Dimensional Conformal Radiation Therapy (3D-CRT), Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) Techniques for Left-Sided Breast Cancer
    Konstantinou, Evgenia
    Varveris, Antonis
    Solomou, Georgia
    Antoniadis, Chrysostomos
    Tolia, Maria
    Mazonakis, Michalis
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (01):
  • [8] Dosimetric comparison of left-sided whole breast irradiation with 3D-CRT, IP-IMRT and hybrid IMRT
    Xie, Xiaoxue
    Ouyang, Shuyu
    Wang, Hui
    Yang, Wenjuan
    Jin, Hekun
    Hu, Bingqiang
    Shen, Liangfang
    ONCOLOGY REPORTS, 2014, 31 (05) : 2195 - 2205
  • [9] Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
    Liu, Yi-Chi
    Chang, Hung-Ming
    Lin, Hsin-Hon
    Lu, Chia-Chun
    Lai, Lu-Han
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 14
  • [10] Comparison between Three-Dimensional Conformal Radiation Therapy (3DCRT) and Intensity-Modulated Radiation Therapy (IMRT) for Radiotherapy of Cervical Carcinoma: A Heterogeneous Phantom Study
    Raina P.
    Singh S.
    Journal of Biomedical Physics and Engineering, 2022, 12 (05): : 465 - 476