Transcutaneous bilirubin measured on protected skin during phototherapy in term and preterm neonates

被引:0
|
作者
Isleyen, Fatih [1 ]
Celik, Istemi Han [1 ]
Demirel, Nihal [2 ,3 ]
Ercel, Nihan Ozel [4 ]
Isik, Dilek Ulubas [1 ]
Bas, Ahmet Yagmur [2 ,5 ]
机构
[1] Univ Hlth Sci, Etlik Zubeyde Hanim Womens Hlth Teaching & Res Hos, Dept Pediat, Div Neonatol, TR-06010 Ankara, Turkiye
[2] Yildirim Beyazit Univ, Fac Med, Dept Neonatol, Ankara, Turkiye
[3] Univ Hlth Sci Turkey, Bilkent City Hosp, Dept Pediat & Neonatol, TR-06010 Ankara, Turkiye
[4] Mersin Univ, Fac Med, Dept Biostat & Med Informat, Mersin, Turkiye
[5] Univ Hlth Sci Turkey, Etlik City Hosp, Dept Pediat & Neonatol, TR-06010 Ankara, Turkiye
关键词
Indirect hyperbilirubinemia; Phototherapy; Phototherapy-shielded skin; Total serum bilirubin; Transcutaneous bilirubin measurement; INFANTS; ACCURACY; DEVICE;
D O I
10.1016/j.earlhumdev.2023.105858
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Transcutaneous bilirubin (TCB) measurement is a simple, painless, and time-saving alternative for the assessment of TSB (total serum bilirubin) levels. However, TCB measurements obtained during phototherapy can yield inaccurate results. We evaluated the effectiveness of TCB measurements obtained from protected skin areas in patients who underwent phototherapy. Methods: This prospective study included neonates delivered at a gestational age of >= 34(0/7) weeks. TCB measurements were performed at the forehead and the lower end of the sternum using a JM-105 device. Simultaneously, blood samples were collected to determine TSB levels. During phototherapy, the forehead was covered with a photo-opaque patch. TSB and TCB were measured before, during, at the end of, and after phototherapy. Results: In total, 200 neonates, including 110 (55 %) term and 90 (45 %) late preterm infants, were enrolled. Of these neonates, 162 (81 %) were Turkish while 38 (19 %) were refugees from Syria and Iraq. Notably, no statistically significant differences were observed in the TSB and TCB values between the Turkish and refugee groups (p > 0.05). Bland-Altman analysis was conducted between the TCB values obtained from the covered forehead area and TSB values; the analysis revealed moderate, high, and excellent agreements for the first bilirubin measurement and at the end of phototherapy, before phototherapy, and for the second and rebound bilirubin measurements, respectively. Regarding intraclass correlation coefficients, values >0.95, 0.94-0.85, 0.84-0.70, and < 0.7 indicated perfect, high, moderate, and unacceptable compatibilities, respectively. Although a significant association was observed between pre-phototherapy TCB obtained from the sternum and TSB levels, no significant associations were observed during phototherapy. Conclusions: Our findings indicate that the consistency observed between TCB measurements obtained from the protected skin areas and TSB values can be used to monitor phototherapy effectiveness, particularly in late preterm/term infants and those with darker skin tones. Furthermore, this approach can aid in guiding decisions related to treatment termination, evaluating rebound bilirubin levels, minimizing costs, and providing a less invasive testing option.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Transcutaneous Bilirubin Nomogram for Healthy Term and Late Preterm Neonates in First 96 Hours of Life
    Thakkar, Pareshkumar
    Chavda, Hardas
    Doshi, Vikas
    INDIAN PEDIATRICS, 2017, 54 (05) : 369 - 372
  • [42] An Observational Prospective Study to Compare Transcutaneous Bilirubin with Serum Bilirubin in Preterm Newborn Requiring Phototherapy
    Sardar, Syamal
    Sarkar, Nirmalya
    Ghosh, Moumita
    Pal, Somnath
    JOURNAL OF CLINICAL NEONATOLOGY, 2021, 10 (02) : 59 - 67
  • [43] Transcutaneous Bilirubin Measurements Can Be Used to Measure Bilirubin Levels during Phototherapy
    Alsaedi, Saad Abdullah
    INTERNATIONAL JOURNAL OF PEDIATRICS, 2018, 2018
  • [44] Erratum to: Transcutaneous bilirubin nomogram for healthy term and late preterm neonates in first 96 hours of life
    Pareshkumar Thakkar
    Hardas Chavda
    Vikas Doshi
    Indian Pediatrics, 2017, 54 (7) : 594 - 594
  • [45] Accuracy of Transcutaneous Bilirubin Versus Serum Bilirubin Measurement in Preterm Infants Receiving Phototherapy: A Systematic Review
    Hynes, Sharon
    Moore, Zena
    Patton, Declan
    O'Connor, Tom
    Nugent, Linda
    ADVANCES IN NEONATAL CARE, 2020, 20 (06) : E118 - E126
  • [46] TRANSCUTANEOUS BILIRUBINOMETRY DURING & AFTER PHOTOTHERAPY IN PRETERM INFANTS
    Ansari, S.
    Fonseca, R. A.
    Malloy, M.
    Jain, S. K.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (02) : 491 - 491
  • [47] The Impact of Phototherapy on the Accuracy of Transcutaneous Bilirubin Measurements in Neonates: Optimal Measurement Site and Timing
    Ho, Shau-Ru
    Lin, Yu-Chen
    Chen, Chi-Nien
    DIAGNOSTICS, 2021, 11 (09)
  • [48] Reference values of skin bilirubin measured by multiwavelength transcutaneous bilirubinometry during the first 96 h of life in European normal healthy neonates
    De Luca, D.
    Zecca, E.
    Barbato, G.
    Romagnoli, C.
    ACTA PAEDIATRICA, 2007, 96 : 101 - 101
  • [49] Usefulness of transcutaneous bilirubin assessment measured in non-photo-exposed skin to guide the length of phototherapy: an observational study
    Castro, Abdon
    Zozaya, Carlos
    Teresa Cuesta, Ma
    Gonzalez, Marina
    Villar, Gema
    Alcaraz, Andres
    JOURNAL OF PERINATAL MEDICINE, 2019, 47 (05) : 568 - 573
  • [50] Skin thickness in preterm neonates: relationship with skin bilirubin and predicted mortality
    Foligno, Silvia
    Bisceglie, Valeria
    Loi, Barbara
    De Luca, Daniele
    EUROPEAN JOURNAL OF PEDIATRICS, 2024, 183 (08) : 3623 - 3627