Optical Real-Time Cardiorenal Toxin Uric Acid Measurement During Hemodialysis Using a Miniaturized Optical Sensor

被引:0
|
作者
Holmar, Jana [1 ]
Arund, Jurgen [1 ]
Adoberg, Annika [2 ]
Leis, Liisi [2 ]
Luman, Merike [2 ]
Paats, Joosep [1 ]
Pilt, Kristjan [1 ]
Tanner, Risto [1 ]
Fridolin, Ivo [1 ]
机构
[1] Tallinn Univ Technol, Dept Hlth Technol, EE-19086 Tallinn, Estonia
[2] North Estonia Med Ctr, Ctr Nephrol, EE-13419 Tallinn, Estonia
基金
欧盟地平线“2020”;
关键词
D O I
10.1109/EMBC40787.2023.10340379
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Patients with chronic kidney disease (CKD) are at higher cardiovascular risk than the general population. Cardiovascular diseases, vascular calcification among them, are the leading cause of death in these patients. Factors influencing vascular calcification are oxidative stress, inflammation, and accumulation of uremic toxins during CKD. Uric acid is a cardiorenal toxin that accumulates in the case of kidney malfunction. The primary therapy for replacing kidney function and removing toxins from end-stage renal disease patients is hemodialysis. Effective removal of toxins can be estimated by blood or dialysate lab analysis or optical monitoring. In this study, the authors tested a miniaturized optical sensor for monitoring uric acid levels and removal for the first time in a more extensive clinical study, including Hemodialysis (HD) and Post-dilutional online hemodiafiltration (HDF) procedures with different settings in Tallinn, Estonia. The results (Mean +/- SD, Lab vs. Sensor) of the uric acid concentration 57.20 +/- 34.05 vs. 57.22 +/- 33.09 mu mol/L, reduction ratio 68.72 +/- 10.91 vs. 67.89 +/- 12.48 %, and total removed amount 7.00 +/- 2.10 vs. 7.33 +/- 2.29 mmol did not differ significantly from the values obtained from the clinical laboratory (p<0.05).
引用
收藏
页数:4
相关论文
共 50 条
  • [21] An optical, real-time measurement of collagen denaturation
    Sankaran, V
    Walsh, JT
    LASER-TISSUE INTERACTION VIII, PROCEEDINGS OF, 1997, 2975 : 34 - 42
  • [22] Real-time polarimetric optical sensor using macroporous alumina membranes
    Alvarez, Jesus
    Serrano, Carlos
    Hill, Daniel
    Martinez-Pastor, Juan
    OPTICS LETTERS, 2013, 38 (07) : 1058 - 1060
  • [23] Optical tomography: real-time velocity profile measurement using pixel-to-pixel and sensor-to-sensor method
    Rahim, Ruzairi Abdul
    Fea, Pang Jon
    San, Chan Kok
    OPTICAL ENGINEERING, 2006, 45 (03)
  • [24] Real-Time Optical Measurement of Displacements Using Subpixel Image Registration
    Antos, J.
    Nezerka, V.
    Somr, M.
    EXPERIMENTAL TECHNIQUES, 2019, 43 (03) : 315 - 323
  • [25] REAL-TIME PARYLENE COATING THICKNESS MEASUREMENT USING OPTICAL REFLECTOMETRY
    KIM, H
    POWERS, T
    MASON, J
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1982, 21 (03): : 900 - 901
  • [26] Real-Time Optical Measurement of Displacements Using Subpixel Image Registration
    J. Antoš
    V. Nežerka
    M. Somr
    Experimental Techniques, 2019, 43 : 315 - 323
  • [27] Real-time Respiration Measurement during Sleep Using a Microwave Sensor
    Chen, Ying
    Kaneko, Masahiko
    Hirose, Shinichi
    Chen, Wenxi
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3791 - 3794
  • [28] Human health and real-time nitric acid detection in drinking water using optical fiber sensor
    Gupta J.
    Gupta P.
    International Journal of Information Technology, 2024, 16 (4) : 2611 - 2618
  • [29] Real-time estimation of aquaplaning with an optical tyre sensor
    Tuononen, A. J.
    Matilainen, M. J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2009, 223 (D10) : 1263 - 1272
  • [30] An Optical Chiral Sensor Based on Weak Measurement for the Real-Time Monitoring of Sucrose Hydrolysis
    Li, Dongmei
    Weng, Chaofan
    Ruan, Yi
    Li, Kan
    Cai, Guoan
    Song, Chenyao
    Lin, Qiang
    SENSORS, 2021, 21 (03) : 1 - 13