The 3D Printing and Evaluation of Surgical Guides with an Incorporated Irrigation Channel for Dental Implant Placement

被引:5
|
作者
Tuce, Robert-Angelo [1 ]
Neagu, Monica [1 ,2 ]
Pupazan, Vasile [1 ]
Neagu, Adrian [1 ,2 ,3 ]
Arjoca, Stelian [1 ,2 ]
机构
[1] Victor Babes Univ Med & Pharm Timisoara, Dept Funct Sci, Timisoara 300041, Romania
[2] Victor Babes Univ Med & Pharm Timisoara, Ctr Modeling Biol Syst & Data Anal, Timisoara 300041, Romania
[3] Univ Missouri, Dept Phys & Astron, Columbia, MO 65211 USA
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 10期
关键词
osteotomy; surgical drilling; surgical templates; intraosseous temperature; cooling;
D O I
10.3390/bioengineering10101168
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Dental implant insertion requires the preparation of the implant bed via surgical drilling. During this stage, irrigation is essential to avoid thermal damage to the surrounding bone. Surgical guides enhance the accuracy of the implant site preparation, but they mask the drilling site, hampering coolant delivery. A variety of designs are aimed at improving the coolant access to the target site. Using standard dental implant simulation software, this paper presents an in-house design and 3D printing workflow for building surgical guides that incorporate a coolant channel directed toward the entry point of the burr. The proposed design was evaluated in terms of the bone temperature elevations caused by drilling performed at 1500 rpm, under an axial load of 2 kg, and irrigation with 40 mL/min of saline solution at 25 degrees C. Temperature measurements were performed on porcine femoral pieces, in the middle of the cortical bone layer, at 1 mm from the edge of the osteotomy. The mean temperature rise was 3.2 degrees C for a cylindrical sleeve guide, 2.7 degrees C for a C-shaped open-sleeve guide, and 2.1 degrees C for the guide with an incorporated coolant channel. According to a one-way ANOVA, the differences between these means were marginally insignificant (p = 0.056). The individual values of the peak temperature change remained below the bone damage threshold (10 degrees C) in all cases. Remarkably, the distribution of the recorded temperatures was the narrowest for the guide with internal irrigation, suggesting that, besides the most effective cooling, it provides the most precise control of the intraosseous temperature. Further studies could test different design variants, experimental models (including live animals), and might involve computer simulations of the bone temperature field.
引用
收藏
页数:13
相关论文
共 50 条
  • [22] An In Vitro Evaluation of the Effect of 3D Printing Orientation on the Accuracy of Implant Surgical Templates Fabricated By Desktop Printer
    Tahir, Nimra
    Abduo, Jaafar
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (09): : 791 - 798
  • [23] Job Placement for Cooperative 3D Printing
    Weber, Daniel H.
    Zhou, Wenchao
    Sha, Zhenghui
    PROCEEDINGS OF ASME 2023 18TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, MSEC2023, VOL 2, 2023,
  • [24] 3D printing of surgical staples
    Osama Al-Takhayneh
    Holly Warren
    Marc in het Panhuis
    MRS Advances, 2022, 7 : 489 - 494
  • [25] 3D printing and modelling of customized implants and surgical guides for non-human primates
    Chen, Xing
    Possel, Jessy K.
    Wacongne, Catherine
    van Ham, Anne F.
    Klink, P. Christiaan
    Roelfsema, Pieter R.
    JOURNAL OF NEUROSCIENCE METHODS, 2017, 286 : 38 - 55
  • [26] 3D printing of surgical staples
    Al-Takhayneh, Osama
    Warren, Holly
    In Het Panhuis, Marc
    MRS ADVANCES, 2022, 7 (23-24) : 489 - 494
  • [27] Effects of autoclave sterilization on the dimensional stability of implant surgical guides: A 3D in vitro analysis
    Lo Russo, Lucio
    Mariani, Pierluigi
    Ercoli, Carlo
    Caprio, Giusy
    Park, Ji-Man
    Laino, Luigi
    Esperouz, Fariba
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [28] ACL tunnel placement using 3D printed surgical guides - a porcine feasibility study
    Eberlein, Sophie C.
    Hess, Silvan
    Schaible, Samuel F.
    Klenke, Frank M.
    Hecker, Andreas
    3D PRINTING IN MEDICINE, 2025, 11 (01)
  • [29] Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
    Pop, Silvia Izabella
    Dudescu, Mircea
    Mihali, Sorin Gheorghe
    Pacurar, Mariana
    Bratu, Dana Cristina
    POLYMERS, 2022, 14 (10)