A dosimetric comparison of intensity-modulated radiotherapy versus rapid arc in gynecological malignancies: Dose beyond planning target volume, precisely 5Gy volume

被引:0
|
作者
Sidhu, Manjinder Singh [1 ]
Singh, Kulbir [2 ]
Sood, Sandhya [1 ]
Aggarwal, Ritu [1 ]
机构
[1] DMCH Canc Ctr, Dept Radiat Oncol, Ludhiana, Punjab, India
[2] DMCH Canc Ctr, Dept Med Phys, Ludhiana, Punjab, India
关键词
Dosimetric comparison; five gy volume dose; intensity-modulated radiotherapy plan; rapid arc plan; RADIATION-THERAPY; CERVICAL-CANCER; FIXED FIELD; 2ND CANCERS; IMRT; RISK; DELIVERY;
D O I
10.4103/jcrt.jcrt_11_22
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Aim of radiotherapy is precise dose delivery with objective of achieving maximum local control and minimal toxicity by decreasing dose to organ at risk (OAR).This aim can be achieved by technologies like intensity-modulated radiotherapy (IMRT) and volumetric arc therapy. However, later offers comparable or even better plan quality with shorter treatment time. It is important to note that low dose regions are also a concern due long-term risk of developing a second cancer after radiotherapy. The objective of our study is to do dosimetric comparison of IMRT vs. Rapid arc (RA) plan in gynecology cancer and specifically to assess dose beyond planning target volume (PTV), precisely 5 Gy volume. Methods: Each 20 eligible patients underwent radiotherapy planning on eclipse by both IMRT and RA plans as per institution protocols. Comparative dosimetric analysis of both plans was done by paired sample t-test. PTV metrics compared were D95%, homogenecity index (HI), and conformity index (CI). OAR dose compared were bowel V40 Gy <30%, Rectum V30 Gy <60%, Bladder V45 Gy <35%, and bilateral femur head and neck V30 Gy < 50%. Futhermore, calculated monitor units (MUs) were also compared. Finally, volume of normal tissue beyond the PTV, specifically 5 Gy volume, was compared between plans. Results: Dosimetric plan comparison showed statistically significant difference in RA and IMRT plans with improved PTV coverage and better OAR tolerance with RA plan. In addition, MU used were significantly less in RA plan, coupled with reduced V5 Gy volume. Conclusion: In sum, RA plans are dosimetrically significantly better compared to IMRT plans in gynecological malignancies in terms of PTV coverage and OAR sparing. Importantly, not only less MU used but also significantly less normal tissue V5 Gy volume is less in RA compared to IMRT plans.
引用
收藏
页码:1267 / 1271
页数:5
相关论文
共 50 条
  • [41] Dosimetric Comparison of Helical Tomotherapy, Volume-Modulated Arc Therapy, and Fixed-Field Intensity-Modulated Radiation Therapy in Locally Advanced Nasopharyngeal Carcinoma
    Lu, Shan
    Fan, Huiqi
    Hu, Xueyuan
    Li, Xin
    Kuang, Yingying
    Yu, Deyang
    Yang, Shanshan
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [42] Potential for dose escalation in the postprostatectomy setting with intensity-modulated radiation therapy: a dosimetric study using EORTC consensus guidelines for target volume contours
    Harrison, Amy
    Studenski, Matthew
    Harvey, Arthur
    Trabulsi, Edouard J.
    Xiao, Ying
    Yu, Yan
    Dicker, Adam P.
    Showalter, Timothy N.
    PRACTICAL RADIATION ONCOLOGY, 2011, 1 (02) : 105 - 114
  • [43] Why subclinical involvement is prescribed the same high dose as gross tumor volume: A study on high-dose clinical target volume in intensity-modulated radiotherapy plan of nasopharyngeal carcinoma
    Qiu, Zichen
    Lin, Feifei
    Wu, Zheng
    Wu, Taihua
    Wang, Mingli
    Hu, Jiang
    Xie, Dehuan
    Lyu, Shaowen
    Ma, Jun
    Tao, Yalan
    Su, Yong
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2023, 45 (05): : 1206 - 1214
  • [44] Local Failure Rate in Oropharyngeal Carcinoma Patients Treated with Intensity-modulated Radiotherapy Without High-dose Clinical Target Volume
    Almarzouki, Hatim
    Niazi, Tamim
    Hier, Michael
    Mlynarek, Alex
    Lavoie, Isabelle
    Sultanem, Khalil
    CUREUS, 2018, 10 (07):
  • [45] Dose as a function of liver volume and planning target volume in helical tomotherapy, intensity-modulated radiation therapy-based stereotactic body radiation therapy for hepatic metastasis
    Baisden, Joseph M.
    Reish, Andrew G.
    Sheng, Ke
    Larner, James M.
    Kavanagh, Brian D.
    Read, Paul W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (02): : 620 - 625
  • [46] Dosimetric effect of intensity-modulated radiation therapy for postoperative non-small cell lung cancer with and without air cavity in the planning target volume
    Gan, Wutian
    Duan, Yanhua
    Wang, Hao
    Shao, Yan
    Chen, Hua
    Feng, Aihui
    Gu, Hengle
    Huang, Ying
    Ying, Yanchen
    Fu, Xiaolong
    Quan, Hong
    Xu, Zhiyong
    MEDICAL DOSIMETRY, 2022, 47 (01) : 32 - 37
  • [47] Dosimetric comparison of volumetric-arc therapy versus sliding window intensity-modulated radiotherapy in postoperative treatment for primary soft tissue sarcoma of the thigh
    Ortiz Gonzalez, Irene
    Morera Cano, Daniel
    Roncero Sanchez, Raquel
    Mateos Salvador, Pedro
    Valencia Blanco, Lourdes
    Vidal Borras, Meritxell
    Aymar Salis, Neus
    Gadea Quinteiro, Jon
    Jimenez Jimenez, Esther
    Font Gelabert, Joan
    Pardo Masferrer, Jose
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2019, 15 (06) : 371 - 376
  • [48] Comparison of biologically effective dose for treatment planning in the fixed-beam intensity-modulated radiotherapy and the volumetric-modulated arc therapy for the typical types of cancer
    Wang, Shichao
    Zhou, Lin
    Xue, Jianxin
    Lan, Jie
    Deng, Lei
    Yi, Tingwu
    Lu, You
    RADIATION PHYSICS AND CHEMISTRY, 2019, 157 : 102 - 108
  • [49] Dosimetric differences between intensity-modulated radiotherapy based on equivalent uniform dose and dose-volume optimization in stage III non-small cell lung cancer
    Li, Zhenhu
    Zhao, Qiuxia
    Yin, Haitao
    Ren, Hongrong
    Zhou, Yun
    Zhou, Chong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (07): : 5195 - 5200
  • [50] Estimated limits of dose escalation for localized prostate cancer using intensity modulated radiotherapy, varied planning target volume margins and established dose constraints: Correlation with prostate size and target volume overlap with the rectum
    Goulet, CC
    Herman, MG
    Hillman, DW
    Davis, BJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S209 - S209