Effects of parameters on radiofrequency guidewire ablation: In vitro and in vivo experiments

被引:1
|
作者
Zuo, Zhongyin [1 ,2 ]
Li, Sainan [3 ]
Xuan, Fengqi [3 ]
Zhang, Jie [3 ]
Liu, Zichen [3 ]
Zhang, Shibei [4 ]
Liang, Ming [4 ,5 ]
Wang, Zulu [4 ,5 ]
机构
[1] Gen Hosp Northern Theater Command Jinzhou Med Univ, Dept Cardiol, Shenyang, Peoples R China
[2] Tongji Univ, Dept Cardiol, Shanghai Peoples Hosp 4, Sch Med, Shanghai, Peoples R China
[3] China Med Univ, Dept Cardiol, Gen Hosp Northern Theater Command, Shenyang, Peoples R China
[4] Gen Hosp Northern Theater Command, Dept Cardiol, Shenyang 110016, Peoples R China
[5] Gen Hosp Northern Theater Command, Natl Key Lab Frigid Zone Cardiovasc Dis, Shenyang, Peoples R China
关键词
guidewire ablation; lesion radius; radiofrequency ablation; safety power; ELECTRODE-TISSUE CONTACT; VENTRICULAR-ARRHYTHMIAS; CATHETER ABLATION; IMPEDANCE; TEMPERATURE;
D O I
10.1111/jce.16066
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundA novel ablation technique with guidewire has emerged as a promising approach for mapping and ablation of arrhythmias originating from left ventricular summit. However, its biophysical characteristics have not been fully clarified.Methods and ResultsIn the in vitro experiment, guidewire ablation (GA) was performed in vessel models of 1.17 and 2.24 mm to determine the maximum safety power. Then with the maximum safety power, the predictive value of generator impedance (GI) drop on lesion radius was explored. In the in vivo experiment, the feasibility of the maximum safety power and lesion formation was verified in the living swine. It was found that in both groups, the incidence of steam pops increased along with the raise of ablation power, and the maximum safety power was 10 W for the 1.17-mm group and 15 W for the 2.24-mm group. There was a strong linear correlation between GI drop and maximum lesion radius (in 1.17 mm-10-W group: r = .961; in 2.24 mm-15-W group: r = .918). In the in vivo experiment, besides ventricular fibrillation happened once, no other complications were observed, and lesions were found at both 48-h and 8-week groups.ConclusionsThe safety power of GA should be adjusted according to the diameter of the vessel. Besides, the GI drop can predict the lesion radius during GA.
引用
收藏
页码:2535 / 2544
页数:10
相关论文
共 50 条
  • [31] Intrahepatic radiofrequency ablation versus electrochemical treatment in vivo
    Czymek, Ralf
    Nassrallah, Jan
    Gebhard, Maximilian
    Schmidt, Andreas
    Limmer, Stefan
    Kleemann, Markus
    Bruch, Hans-Peter
    Hildebrand, Philipp
    SURGICAL ONCOLOGY-OXFORD, 2012, 21 (02): : 79 - 86
  • [32] Experiments In Vivo, In Vitro, and In Cathedra
    Buss, Sarah
    ETHICS, 2014, 124 (04) : 860 - 881
  • [33] Autonomic effects of radiofrequency catheter ablation
    Duru, F
    Bauersfeld, U
    Candinas, R
    EUROPACE, 2000, 2 (02): : 181 - 185
  • [34] Steam Ablation Versus Radiofrequency and Laser Ablation: An In Vivo Histological Comparative Trial
    Thomis, S.
    Verbrugghe, P.
    Milleret, R.
    Verbeken, E.
    Fourneau, I.
    Herijgers, P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (03) : 378 - 382
  • [35] SIGNIFICANCE OF PHYSICAL PARAMETERS FOR THE EFFICACY OF RADIOFREQUENCY CATHETER ABLATION
    HOFFMANN, E
    DORWARTH, U
    PULTER, R
    GOKEL, M
    STEINBECK, G
    BIOMEDIZINISCHE TECHNIK, 1992, 37 (04): : 62 - 68
  • [36] IN-VITRO STUDY OF A RADIOFREQUENCY GUIDEWIRE AIMED AT RECANALIZATION OF TOTALLY OCCLUDED PERIPHERAL ARTERIES
    MELNIK, I
    DUPOUY, P
    KVASNICKA, J
    BHATIA, A
    GESCHWIND, HJ
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (02): : 189 - 196
  • [37] Radiofrequency ablation using injectable cooled electrode: the effects of lidocaine injection in ex vivo study
    Park, Sun-Young
    Chung, Hye Won
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Lee, Min Hee
    Lee, Joon Woo
    ACTA RADIOLOGICA, 2020, 61 (02) : 219 - 226
  • [38] Radiofrequency ablation of porcine liver in vivo -: Effects of blood flow and treatment time on lesion size
    Patterson, EJ
    Scudamore, CH
    Nagy, AG
    Buczkowski, AK
    ANNALS OF SURGERY, 1998, 227 (04) : 559 - 565
  • [39] Effects of vascular perfusion on coagulation size in radiofrequency ablation of ex vivo perfused bovine livers
    Bitsch, RG
    Düx, M
    Helmberger, T
    Lubienski, A
    INVESTIGATIVE RADIOLOGY, 2006, 41 (04) : 422 - 427
  • [40] The effect of radiofrequency ablation on different organs: Ex vivo and in vivo comparative studies
    Kim, Yoo Na
    Rhim, Hyunchul
    Choi, Dongil
    Kim, Young-sun
    Lee, Min Woo
    Chang, Ilsoo
    Lee, Won Jae
    Lim, Hyo K.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 526 - 532