Parametric study on lateral behavior of totally precast RC shear wall with horizontal bolted connection

被引:9
|
作者
Sun, Jian [1 ]
Wang, Tianmeng [1 ]
Sun, Haoyuan [1 ]
Ruan, Shihao [1 ]
Qiu, Hongxing [1 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Nanjing 211102, Peoples R China
关键词
Totally precast reinforced concrete shear wall; Horizontal connection; High strength bolt; ABAQUS; Finite element analysis; SEISMIC PERFORMANCE;
D O I
10.1016/j.istruc.2023.105100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dry-type connections have gained considerable popularity worldwide due to their superior construction efficiency and quality. However, a significant drawback of most conventional dry-type connections is the direct embedding of connectors in the concrete wall panel, consequently causing stress concentration in the connections and leading to extensive spalling of concrete. This study introduces an innovative high-strength bolted connection as a solution to address the problem of stress concentration in concrete. To evaluate the seismic performance of the high-strength bolted connection, monotonic lateral loading tests were conducted. In this study, a finite element (FE) model was developed using ABAQUS software, and validated through experimental results. Furthermore, a parametric study was conducted using the FE model to assess the influence of several key design parameters on the lateral response and anti-slip capacity of the bolted connection in the precast shear wall. These parameters include bolt specifications, anti-slip coefficient, flange thickness of the H-connector, widths of the initial gap, axial compression ratio, and connection arrangement. The results indicate that the antislip capacity is not significantly influenced by the flange thickness of H-connectors and initial gap width, but it increases with an increase in bolt specification, slip coefficient, and axial compression ratio. Additionally, the ultimate bearing capacity of the precast shear wall remains unaffected by both the anti-slip coefficient and the initial gap width. Moreover, the high-stress area of the H-connector is concentrated at the ends. Finally, the design parameters are recommended according to the numerical analysis results.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Experimental study of lateral load behavior of H-shaped precast reinforced concrete shear walls with bolted steel connections
    Sun, Jian
    Qiu, Hongxing
    Lu, Yong
    Jiang, Hongbo
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (15):
  • [32] A Numerical Study on the Seismic Performance of a Horizontal Dry Connection for Precast Concrete Shear Walls
    Emmanuel Wayne Sookree
    Zhuye Huang
    Zhenyu Wang
    KSCE Journal of Civil Engineering, 2023, 27 : 1617 - 1639
  • [33] A Numerical Study on the Seismic Performance of a Horizontal Dry Connection for Precast Concrete Shear Walls
    Sookree, Emmanuel Wayne
    Huang, Zhuye
    Wang, Zhenyu
    KSCE JOURNAL OF CIVIL ENGINEERING, 2023, 27 (04) : 1617 - 1639
  • [34] Experimental and numerical study on mechanical properties of PC shear wall bolted connection joints
    Gong, Yindong
    Chu, Yunpeng
    Liu, Yanhui
    Zhai, Zhipeng
    ADVANCES IN STRUCTURAL ENGINEERING, 2025, 28 (02) : 227 - 245
  • [35] Shear behavior of horizontal joints between precast panels
    Pramodh R.
    Shripriyadharshini V.
    Vidjeapriya R.
    Asian Journal of Civil Engineering, 2018, 19 (6) : 651 - 662
  • [36] A Precast Shear Wall Case Study
    Harasimowicz, Anthony P.
    Concrete International, 2021, 43 (06) : 45 - 47
  • [37] Experimental Study on Seismic Behavior of Double-Wall Precast Concrete Shear Wall
    Xiao, Quandong
    Guo, Zhengxing
    ADVANCED CONSTRUCTION TECHNOLOGIES, 2014, 919-921 : 1812 - 1816
  • [38] Research on design and mechanical behavior of a new horizontal connection device of prefabricated shear wall
    Xiong, Ergang
    Zhang, Hairong
    Fu, Chongyang
    Hu, Qinbin
    Fan, Yujiang
    Taciroglu, Ertugrul
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 370
  • [39] Study on seismic performance and construction measures optimization of precast fabricated RC integration shear wall
    Hu W.
    Zhai X.
    Jiang H.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2016, 37 (08): : 1 - 10
  • [40] Restoring force model for bolted-connection assembled shear wall
    Jiang S.
    Zhao J.
    Lian S.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2022, 54 (04): : 55 - 64