Parametric study on lateral behavior of totally precast RC shear wall with horizontal bolted connection

被引:9
|
作者
Sun, Jian [1 ]
Wang, Tianmeng [1 ]
Sun, Haoyuan [1 ]
Ruan, Shihao [1 ]
Qiu, Hongxing [1 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab Concrete & Prestressed Concrete Struct, Nanjing 211102, Peoples R China
关键词
Totally precast reinforced concrete shear wall; Horizontal connection; High strength bolt; ABAQUS; Finite element analysis; SEISMIC PERFORMANCE;
D O I
10.1016/j.istruc.2023.105100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Dry-type connections have gained considerable popularity worldwide due to their superior construction efficiency and quality. However, a significant drawback of most conventional dry-type connections is the direct embedding of connectors in the concrete wall panel, consequently causing stress concentration in the connections and leading to extensive spalling of concrete. This study introduces an innovative high-strength bolted connection as a solution to address the problem of stress concentration in concrete. To evaluate the seismic performance of the high-strength bolted connection, monotonic lateral loading tests were conducted. In this study, a finite element (FE) model was developed using ABAQUS software, and validated through experimental results. Furthermore, a parametric study was conducted using the FE model to assess the influence of several key design parameters on the lateral response and anti-slip capacity of the bolted connection in the precast shear wall. These parameters include bolt specifications, anti-slip coefficient, flange thickness of the H-connector, widths of the initial gap, axial compression ratio, and connection arrangement. The results indicate that the antislip capacity is not significantly influenced by the flange thickness of H-connectors and initial gap width, but it increases with an increase in bolt specification, slip coefficient, and axial compression ratio. Additionally, the ultimate bearing capacity of the precast shear wall remains unaffected by both the anti-slip coefficient and the initial gap width. Moreover, the high-stress area of the H-connector is concentrated at the ends. Finally, the design parameters are recommended according to the numerical analysis results.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Research on seismic behavior of precast concrete shear wall with new steel plate-bolted horizontal connection
    Yu, Haifeng
    Zhang, Huijie
    Zhang, Pengfei
    Ma, Kang
    Zhang, Hua
    Qiao, Jin
    JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [2] Experimental validation of horizontal joints in an innovative totally precast shear wall system
    Sun, Jian
    Qiu, Hongxing
    Lu, Bo
    Journal of Southeast University (English Edition), 2015, 31 (01) : 124 - 129
  • [3] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    SUN Jian
    QIU HongXing
    YANG Yuan
    LU Bo
    Science China(Technological Sciences), 2015, 58 (08) : 1439 - 1448
  • [4] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    SUN Jian
    QIU HongXing
    YANG Yuan
    LU Bo
    Science China(Technological Sciences), 2015, (08) : 1439 - 1448
  • [5] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    Jian Sun
    HongXing Qiu
    Yuan Yang
    Bo Lu
    Science China Technological Sciences, 2015, 58 : 1439 - 1448
  • [6] Experimental and analytical studies on the deformability of a precast RC shear wall involving bolted connections
    Sun Jian
    Qiu HongXing
    Yang Yuan
    Lu Bo
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2015, 58 (08) : 1439 - 1448
  • [7] Experimental Study and Numerical Simulation of Precast Shear Wall with Rabbet-Unbonded Horizontal Connection
    Chong-fang Sun
    Shu-ting Liang
    Xiao-jun Zhu
    Hu Li
    Jian-min Guo
    Gang Li
    Ya-min Song
    Dong-yue Wu
    International Journal of Concrete Structures and Materials, 2020, 14
  • [8] Experimental Study and Numerical Simulation of Precast Shear Wall with Rabbet-Unbonded Horizontal Connection
    Sun, Chong-fang
    Liang, Shu-ting
    Zhu, Xiao-jun
    Li, Hu
    Guo, Jian-min
    Li, Gang
    Song, Ya-min
    Wu, Dong-yue
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2020, 14 (01)
  • [9] Lateral load behaviour of a rectangular precast shear wall involving vertical bolted connections
    Sun, Jian
    Qiu, Hongxing
    Jiang, Hongbo
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (05) : 1211 - 1224
  • [10] Experiment and numerical study of a new bolted steel plate horizontal joints for precast concrete shear wall structures
    Cheng, Bei
    Cai, Yuan
    Looi, Daniel T. W.
    STRUCTURES, 2021, 32 : 760 - 777