Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China: A single-center experience

被引:0
|
作者
Zhang, Lei [1 ,2 ]
Li, Xiao [1 ,2 ]
Liang, Yixiu [1 ,2 ]
Wang, Jingfeng [1 ,2 ]
Li, Minghui [1 ,2 ]
Pan, Lei [1 ,2 ]
Chen, Xueying [1 ,2 ]
Qin, Shengmei [1 ,2 ]
Bai, Jin [1 ,2 ]
Wang, Wei [1 ,2 ]
Su, Yangang [1 ,2 ,3 ]
Ge, Junbo [1 ,2 ,3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Dept Cardiol, Shanghai, Peoples R China
[2] Shanghai Clin Res Ctr Intervent Med, Natl Clin Res Ctr Intervent Med, Shanghai, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Shanghai Inst Cardiovasc Dis, Dept Cardiol, Xietu Rd 1069, Shanghai, Peoples R China
关键词
Subcutaneous implantable cardioverter-defibrillator; Sudden cardiac death; Efficacy; Safety; Chinese population; S-ICD; OUTCOMES; PREVENTION; SOCIETY; SHOCKS;
D O I
10.1007/s00059-023-05192-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSubcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S-ICD implantation in the Chinese population is safe and feasible and should be promoted in the future.MethodsConsecutive patients undergoing S-ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed.ResultsIn total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%.ConclusionBased on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S-ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.
引用
收藏
页码:462 / 469
页数:8
相关论文
共 50 条
  • [22] Is it safe to allow patients with implantable cardioverter-defibrillators to drive? Learnings from a single center experience
    Curnis, Antonio
    Mascioli, Giosue
    Bontempi, Luca
    Cerini, Manuel
    Bignotti, Tommaso
    Bonetti, Gabriele
    Cas, Livio Dei
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (12) : 1241 - 1245
  • [23] Implantable cardioverter-defibrillators in heart transplant recipients - a single centre experience
    Neylon, A.
    Canniffe, C.
    Parlon, B.
    Mahon, N.
    Egan, J.
    McCarthy, J.
    O'Neill, J. O.
    EUROPEAN HEART JOURNAL, 2013, 34 : 258 - 258
  • [24] Implantable Cardioverter-Defibrillators in Heart Transplant Recipients: A Single Centre Experience
    Neylon, A.
    Canniffe, C.
    Parlon, B.
    Egan, J.
    McCarthy, J.
    Mahon, N.
    O'Neill, J. O.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2013, 182 : S380 - S381
  • [25] BETTER THAN YOU THINK: APPROPRIATE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS AT A SINGLE ACADEMIC CENTER
    Shah, N.
    Ross, S.
    Njapo, S. Noutong
    Merritt, J.
    Kolarich, A.
    Kaufmann, M.
    Burkart, T.
    Miles, W.
    Winchester, D.
    McKillop, M.
    CARDIOLOGY, 2017, 137 : 246 - 246
  • [26] Single-Center Experience With Implantable Cardioverter Defibrillators in Adults With Complex Congenital Heart Disease
    Khanna, Amber D.
    Warnes, Carole A.
    Phillips, Sabrina D.
    Lin, Grace
    Brady, Peter A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (05): : 729 - 734
  • [27] Anesthesia care for subcutaneous implantable cardioverter/defibrillator placement: a single-center experience
    Essandoh, Michael K.
    Portillo, Juan G.
    Weiss, Raul
    Otey, Andrew J.
    Zuleta-Alarcon, Alix N.
    Humeidan, Michelle L.
    Torres, Jose L.
    Flores, Antolin S.
    Castellon-Larios, Karina
    Abdel-Rasoul, Mahmoud
    Andritsos, Michael J.
    Perez, William J.
    Stein, Erica J.
    Turner, Katja R.
    Dimitrova, Galina T.
    Awad, Hamdy
    Bhandary, Sujatha P.
    Tripathi, Ravi S.
    Joseph, Nicholas C.
    Hummel, John D.
    Augostini, Ralph S.
    Kalbfleisch, Steven J.
    Tyler, Jaret D.
    Houmsse, Mahmoud
    Daoud, Emile G.
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 31 : 53 - 59
  • [28] Mortality benefit of implantable cardioverter-defibrillators for primary prevention of sudden cardiac death: a real-world analysis
    Auricchio, A.
    Ahmed, A.
    Mittal, S.
    Pickett, R. A.
    Wilkoff, B. L.
    Jacobsen, L.
    Marti, A. K.
    Soderland, D. M.
    Curtis, A. B.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [29] REAL-WORLD EXPERIENCE FOR BIOLOGIC USE IN IBD IN THAI: A SINGLE-CENTER EXPERIENCE
    Limsrivilai, Julajak
    Chaemsupaphan, Thanaboon
    Sattayalertyanyong, Onuma
    Subdee, Nichcha
    Permpim, Parinya
    Pausawasdi, Nonthalee
    GASTROENTEROLOGY, 2023, 164 (04) : S69 - S69
  • [30] “Real-world” analysis of battery longevity of implantable cardioverter-defibrillators: an in-depth analysis of a prospective defibrillator database
    Diogo de Almeida Fernandes
    Natália António
    Pedro A. Sousa
    Leonor Preto
    Marta Madeira
    Luís Elvas
    Lino Gonçalves
    BMC Cardiovascular Disorders, 23