A Horizontal Stiffener Detailing for Shear Links at the Link-to-Column Connection in Eccentrically Braced Frames

被引:5
|
作者
Chao, Shih-Ho [1 ]
Almasabha, Ghassan [2 ]
Price, Brandon [3 ]
Jiansinlapadamrong, Chatchai [4 ]
机构
[1] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
[2] Hashemite Univ, Fac Engn, Dept Civil Engn, Zarqa 13133, Jordan
[3] DN Tanks, 410 E Trinity Blvd, Dallas, TX 75050 USA
[4] AG&E, 15280 Addison Rd, Addison, TX 75001 USA
关键词
Eccentrically braced frames; Shear link; Steel frames; Seismic design; Seismic analysis; Steel columns; Digital image correlation; PLASTIC OVERSTRENGTH; BEHAVIOR; FRACTURE;
D O I
10.1061/JSENDH.STENG-12090
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the performance and viability of a horizontal stiffener detailing (HSD) to (1) be used at the link-to-column connection in a D-braced eccentrically braced frame layout where conventional link-to-column connections show poor performance, (2) minimize the overstrength factor of shear links caused by the hardening of link flanges, and (3) mitigate an undesirable failure mechanism previously observed in shear links fabricated using ASTM A992 steel. HSD and conventional stiffener detailing (CSD) were tested using W460x60 sections under two loading protocols, including one simulating near-collapse excitation. While the flanges of CSD shear links are greatly stiffened by vertical stiffeners, webs of HSD shear links exhibit inelastic buckling at large rotation angles. This allows the flanges to freely deform, thereby reducing the likelihood of brittle fracture at the flange connections, as well as undesirable link overstrength induced by the flange contribution. This study shows that the horizontal stiffener configuration developed a ductile failure mechanism resulting from gradually increasing local buckling in the web. The strength degradation of links with horizontal stiffener detailing was much more gradual due to the ever-increasing web buckling, unlike the sudden brittle fracture at the flange-to-column face of links with CSD. This research shows that the HSD is a viable and economic alternative for shear links, which has the potential to decrease welding in the shear link while exhibiting adequate seismic performance. HSD also maintains a low overstrength factor and utilizes a simplistic design approach. Finally, the bolted extended end-plate connection and its details at the link ends used in the test experiment provided a viable solution for replaceable links.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] BOLTED LINK-COLUMN JOINTS IN ECCENTRICALLY BRACED FRAMES
    GHOBARAH, A
    RAMADAN, T
    ENGINEERING STRUCTURES, 1994, 16 (01) : 33 - 41
  • [22] BEHAVIOR OF BOLTED LINK COLUMN JOINTS IN ECCENTRICALLY BRACED FRAMES
    RAMADAN, T
    GHOBARAH, A
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1995, 22 (04) : 745 - 754
  • [23] Experimental investigation of an innovative very short shear link with shear slotted bolted connection in eccentrically braced frames
    Hu, Shujun
    Liu, Shangwen
    Xu, Hongwei
    Zeng, Sizhi
    Zhang, Bo
    Yu, Yujie
    STRUCTURES, 2024, 66
  • [24] Experimental study of replaceable shear links for eccentrically braced steel frames
    Yin Z.
    Li J.
    Dong L.
    Xu J.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (09): : 157 - 165
  • [25] Experimental Validation of Replaceable Shear Links for Eccentrically Braced Steel Frames
    Mansour, Nabil
    Christopoulos, Constantin
    Tremblay, Robert
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2011, 137 (10): : 1141 - 1152
  • [26] Frictional mid-spliced shear links for eccentrically braced frames
    Ozkilic, Yasin Onuralp
    Un, Elif Muge
    Topkaya, Cem
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (15): : 5050 - 5071
  • [27] Proposed Stiffener Spacing Requirements for the Seismic Design of Short Links in Eccentrically Braced Steel Frames
    Skretas, Nikolaos G.
    Karavasilis, Theodore L.
    Lignos, Dimitrios G.
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (06)
  • [28] Seismic performance assessment of eccentrically braced steel frames with variable-cross-section horizontal shear links
    Ma, Kang
    Ye, Xihao
    Wu, Ruoyang
    Yu, Haifeng
    Wu, Yangzhou
    Jiang, Luzhen
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (10) : 2089 - 2102
  • [29] Experimental Testing and Design of High Performance Shear Links for Eccentrically Braced Frames
    Volynkin-Ewens D.
    Clifton G.C.
    Dusicka P.
    Volynkin-Ewens, Dimitry (dim.voly@gmail.com), 2018, Trans Tech Publications Ltd (763 KEM) : 384 - 393
  • [30] Column Link Behavior in Eccentrically Braced Composite 3-Dimensional Frames
    Reena, G. Celine
    Gurupatham, Beulah Gnana Ananthi
    Tsavdaridis, Konstantinos Daniel
    BUILDINGS, 2023, 13 (12)