Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study

被引:8
|
作者
Kernen, Florian [1 ]
Braendle, Dominik [1 ]
Wagendorf, Oliver [2 ,3 ,4 ,5 ]
Recca, Mario [6 ]
Mehrhof, Juergen [7 ]
Vach, Kirstin [8 ]
Nahles, Susanne [6 ]
Nelson, Katja [1 ]
Fluegge, Tabea [6 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg Translat Implantol, Freiburg, Germany
[2] Dept Oral & Maxillofacial Surg, Berlin, Germany
[3] Free Univ Berlin, Berlin, Germany
[4] Humboldt Univ, Berlin, Germany
[5] Charite Univ Med Berlin, Berlin Inst Hlth, Berlin, Germany
[6] Univ Freiburg, Fac Med, Med Ctr, Dept Prosthet Dent, Freiburg, Germany
[7] Mehrhof Implant Technol GmbH, Berlin, Germany
[8] Univ Freiburg, Fac Med, Med Ctr, Inst Med Biometry & Stat, Freiburg, Germany
关键词
accuracy; dental implant; dental Impression; digital Dentistry; digital impression; intraoral scanner; optical Imaging; scan body; SURFACE RECONSTRUCTION; IMPRESSIONS;
D O I
10.1111/clr.14107
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo. Materials and Methods: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (alpha =.05). Results: Total mean linear deviation within the CS group was 189 mu m without scan aid and 135 mu m when using the scan aid. The TR group's total mean deviation was 165 mu m with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p =.001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR-SA group compared to 86% for the TR-NO group, 83% for the CS-SA, and 70% for the CS-NO group, respectively. Conclusions: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.
引用
收藏
页码:793 / 801
页数:9
相关论文
共 50 条
  • [21] Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
    Mueller, Philipp
    Ender, Andreas
    Joda, Tim
    Katsoulis, Joannis
    QUINTESSENCE INTERNATIONAL, 2016, 47 (04): : 343 - 349
  • [22] Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study
    Osman, Reham Bassuni
    Alharbi, Nawal Murshed
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 821 - 828
  • [23] Superimposition of intraoral scans of an edentulous arch with implants and implant-supported provisional restoration, implementing a novel implant prosthetic scan body
    Ntovas, Panagiotis
    Spanopoulou, Maria
    Martin, William
    Sykaras, Nikitas
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (03) : 475 - 480
  • [24] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572
  • [25] Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study
    Motel, Constantin
    Kirchner, Elena
    Adler, Werner
    Wichmann, Manfred
    Matta, Ragai Edward
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (04): : 309 - 314
  • [26] Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan
    Deferm, Julie Tilly
    Baan, Frank
    Nijsink, Johan
    Verhamme, Luc
    Maal, Thomas
    Meijer, Gert
    IMAGING SCIENCE IN DENTISTRY, 2023, 53 (01) : 21 - 26
  • [27] Comparative Analysis of Intraoral Scanner Accuracy in a Six-Implant Complete-Arch Model: An In Vitro Study
    Ferrini, Francesco
    Mazzoleni, Federica
    Barbini, Matteo
    Coppo, Carlotta
    Di Domenico, Giovanna Laura
    Gherlone, Enrico Felice
    PROSTHESIS, 2024, 6 (02): : 401 - 412
  • [28] Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study
    Elawady, Dina Mohamed Ahmed
    Ibrahim, Wafaa Ibrahim
    Ghanem, Radwa Gamal
    Osman, Reham Bassuni
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (04): : 201 - 211
  • [29] Accuracy of Additively Manufactured Dental Casts Compared with That of Virtual Scan Data Obtained with an Intraoral Scanner: An In Vitro Study
    Kim, Gi Youn
    Li, Jiayi
    Moon, Hong Seok
    Oh, Kyung Chul
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [30] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180