Ion transmission in an electrospray ionization-mass spectrometry interface using an S-lens

被引:1
|
作者
Yan, Yihui [1 ]
Schmitt, Lucas [1 ]
Khramchenkova, Anastasiya [1 ]
Lengyel, Jozef [1 ,2 ]
机构
[1] Tech Univ Munich, Chair Phys Chem, TUM Sch Nat Sci, Garching, Germany
[2] Tech Univ Munich, TUM Sch Nat Sci, Lichtenbergstr 4, D-85748 Garching, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2023年 / 58卷 / 07期
关键词
ion trajectory simulation; ion transfer; nanoelectrospray; RF focusing; stacked ring ion guide; FUNNEL INTERFACE; GAS-FLOW; ESI; MS; EFFICIENCY; TRANSPORT; NANOELECTROSPRAY; EMITTERS; TRAP;
D O I
10.1002/jms.4955
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present the design and performance of an in-house built electrospray ionization-mass spectrometry (ESI-MS) interface equipped with an S-lens ion guide. The ion source was designed specifically for our ion beam experiments to investigate the chemical reactivity and deposition of the clusters and nanoparticles. It includes standard ESI-MS interface components, such as nanoelectrospray, ion transfer capillary, and the S-lens. A custom design enables systematic optimization of all relevant factors influencing ion formation and transfer through the interface. By varying the ESI voltage and flow rate, we determined the optimal operating conditions for selected silica emitters. A comparison of the pulled silica emitters with different tip inner diameters reveals that the total ion current is highest for the largest tip, whereas a tip with the smallest diameter exhibited the highest transmission efficiency through the ESI-MS interface. Ion transmission through the transfer capillary is strongly limited by its length, but the loss of ions can be reduced by increasing the capillary voltage and temperature. The S-lens was characterized over a wide range of RF frequencies and amplitudes. Maximum ion current was detected at RF amplitudes greater than 50 V peak-to-peak (p/p) and frequencies above 750 kHz, with a stable ion transmission region of about 20%. A factor of 2.6 increase in total ion current is observed for 650 kHz as RF amplitudes reach 400 V p/p. Higher RF amplitudes also focus the ions into a narrow beam, which mitigates their losses when passing through the ion guide.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Ionization and transmission efficiency in an electrospray ionization-mass spectrometry interface
    Page, Jason S.
    Kelly, Ryan T.
    Tang, Keqi
    Smith, Richard D.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (09) : 1582 - 1590
  • [2] Biases in Ion Transmission Through an Electrospray Ionization-Mass Spectrometry Capillary Inlet
    Page, Jason S.
    Marginean, Ioan
    Baker, Erin S.
    Kelly, Ryan T.
    Tang, Keqi
    Smith, Richard D.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (12) : 2265 - 2272
  • [3] CAPILLARY ELECTROPHORESIS ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
    EDMONDS, CG
    LOO, JA
    BARINAGA, CJ
    UDSETH, HR
    SMITH, RD
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 474 (01): : 21 - 37
  • [4] Desorption electrospray ionization-mass spectrometry of proteins
    Shin, Yong-Seung
    Drolet, Barbara
    Mayer, Richard
    Dolence, Kurt
    Basile, Franco
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (09) : 3514 - 3518
  • [5] Chiral electrokinetic chromatography-electrospray ionization-mass spectrometry using a double junction interface
    Hung, Sih-Hua
    Cheng, Wen-Shuo
    Huang, Ju-Li
    Wang, Che-Wei
    Her, Guor-Rong
    [J]. ELECTROPHORESIS, 2012, 33 (04) : 546 - 551
  • [6] On an Aerodynamic Mechanism to Enhance Ion Transmission and Sensitivity of FAIMS for Nano-Electrospray Ionization-Mass Spectrometry
    Prasad, Satendra
    Belford, Michael W.
    Dunyach, Jean-Jacques
    Purves, Randy W.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (12) : 2143 - 2153
  • [7] Detection and identification of phytobacteria using PCR/electrospray ionization-mass spectrometry
    Postnikova, E.
    Baldwin, C.
    Whitehouse, C. A.
    Sechler, A.
    Schaad, N.
    Sampath, R.
    Harpin, V.
    Li, F.
    Melton, R.
    Blin, L.
    Drader, J.
    Hofstadler, S.
    Schneider, W. L.
    [J]. PHYTOPATHOLOGY, 2007, 97 (07) : S94 - S94
  • [8] CONFIRMATION OF OLIGONUCLEOTIDE SYNTHESIS BY ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
    REDDY, DM
    IDEN, CR
    [J]. AMERICAN LABORATORY, 1995, 27 (09) : 15 - +
  • [9] Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry
    Maxwell, E. Jane
    Chen, David D. Y.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 627 (01) : 25 - 33
  • [10] An ion funnel interface for improved ion focusing and sensitivity using electrospray ionization mass spectrometry
    Shaffer, SA
    Prior, DC
    Anderson, GA
    Udseth, HR
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (19) : 4111 - 4119