Orientation estimation of cryo-EM images using projected gradient descent method

被引:1
|
作者
Pan, Huan [1 ,3 ]
Lu, Jian [1 ,3 ]
Wen, You-Wei [2 ]
Xu, Chen [1 ]
Zeng, Tieyong [4 ]
机构
[1] Shenzhen Univ, Coll Math & Stat, Shenzhen Key Lab Adv Machine Learning & Applicat, Shenzhen 518060, Peoples R China
[2] Yunnan Normal Univ, Sch Math, Kunming 650092, Yunnan, Peoples R China
[3] Natl Ctr Appl Math Shenzhen NCAMS, Shenzhen 518055, Peoples R China
[4] Chinese Univ Hong Kong, Dept Math, Shatin, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
cryo-EM; single particle reconstruction; common lines; orientation estimation; non-convex; orthogonal constraint; projected gradient descent; GENERALIZED POWER METHOD; COMMON-LINES; OPTIMIZATION; PERFORMANCE; ALGORITHMS; RECOVERY;
D O I
10.1088/1361-6420/acbe5f
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Orientation estimation is an important task in three-dimensional cryo-EM image reconstruction. By applying the common line method, the orientation estimation task can be formulated as a least squares (LS) problem or a least un-squared deviation (LUD) problem with orthogonality constraint. However, the non-convexity of the orthogonality constraint introduces numerical difficulties to the orientation estimation. The conventional approach is to reformulate the orthogonality constrained minimization problem into a semi-definite programming problem using convex relaxation strategies. In this paper, we consider a direct way to solve the constrained minimization problem without relaxation. We focus on the weighted LS problem because the LUD problem can be reformulated into a sequence of weighted LS problems using the iteratively re-weighted LS approach. As a classical approach, the projected gradient descent (PGD) method has been successfully applied to solve the convex constrained minimization problem. We apply the PGD method to the minimization problem with orthogonality constraint and show that the constraint set is a generalized prox-regular set, and it satisfies the norm compatibility condition. We also demonstrate that the objective function of the minimization problem satisfies the restricted strong convexity and the restricted strong smoothness over a constraint set. Therefore, the sequence generated by the PGD method converges when the initial conditions are satisfied. Experimental results show that the PGD method significantly outperforms the semi-definite relaxation methods from a computation standpoint, and the mean square error is almost the same or smaller.
引用
收藏
页数:27
相关论文
共 50 条
  • [21] Getting Better Images Easier for Single Particle Cryo-EM
    Cheng, Anchi
    FASEB JOURNAL, 2019, 33
  • [22] The cryo-EM method microcrystal electron diffraction (MicroED)
    Nannenga, Brent L.
    Gonen, Tamir
    NATURE METHODS, 2019, 16 (05) : 369 - 379
  • [23] The cryo-EM method microcrystal electron diffraction (MicroED)
    Brent L. Nannenga
    Tamir Gonen
    Nature Methods, 2019, 16 : 369 - 379
  • [24] Estimation of IMU and MARG orientation using a gradient descent algorithm
    Madgwick, Sebastian O. H.
    Harrison, Andrew J. L.
    Vaidyanathan, Ravi
    2011 IEEE INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2011,
  • [25] CESPED: A benchmark for supervised particle pose estimation in cryo-EM
    Sanchez-Garcia, Ruben
    Saur, Michael
    Vargas, Javier
    Poelking, Carl
    Deane, Charlotte M.
    PHYSICAL REVIEW RESEARCH, 2024, 6 (02):
  • [26] A NEW AND SIMPLE METHOD FOR CRYO-EM SPECIMEN PREPARATION
    Zhou, Jingjing
    Xu, Hongyi
    Carroni, Marta
    Lebrette, Hugo
    Wallden, Karin
    Hogbom, Martin
    Zou, Xiaodong
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2019, 75 : E82 - E82
  • [27] Urdnet: A Cryo-EM Particle Automatic Picking Method
    Ouyang, Jianquan
    Zhang, Yue
    Fang, Kun
    Liu, Tianming
    Pan, Xiangyu
    CMC-COMPUTERS MATERIALS & CONTINUA, 2022, 72 (01): : 1593 - 1610
  • [28] A Dimension Reduction Method for cryo-EM Image Analysis
    Tu, I-Ping
    BIOPHYSICAL JOURNAL, 2018, 114 (03) : 42A - 42A
  • [29] Efficient Cryo-Em: Measuring the Effect of Particle Orientation Distribution on Resolution
    Naydenova, Katerina
    Russo, Christopher J.
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 576A - 576A
  • [30] A Method for Generation of Synthetic 2D and 3D Cryo-EM Images
    N. A. Anoshina
    T. B. Sagindykov
    D. V. Sorokin