Calibration-free blood pressure estimation based on a convolutional neural network

被引:0
|
作者
Cho, Jinwoo [1 ]
Shin, Hangsik [2 ,5 ]
Choi, Ahyoung [3 ,4 ]
机构
[1] Bud on Co Ltd, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Digital Med, Seoul, South Korea
[3] Gachon Univ, Dept AI Software, Seongnam, South Korea
[4] Gachon Univ, Dept AI Software, Seongnam 13120, South Korea
[5] Univ Ulsan, Asan Med Ctr, Dept Digital Med, Coll Med, Seoul 05505, South Korea
基金
新加坡国家研究基金会;
关键词
blood pressure estimation; convolutional neural network; electrocardiogram; photoplethysmogram; wearable environment; PULSE TRANSIT-TIME; WAVE; VARIABILITY; DISPERSION; DURATION;
D O I
10.1111/psyp.14480
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
In this study, we conducted research on a deep learning-based blood pressure (BP) estimation model suitable for wearable environments. To measure BP while wearing a wearable watch, it needs to be considered that computing power for signal processing is limited and the input signals are subject to noise interference. Therefore, we employed a convolutional neural network (CNN) as the BP estimation model and utilized time-series electrocardiogram (ECG) and photoplethysmogram (PPG) signals, which are quantifiable in a wearable context. We generated periodic input signals and used differential and thresholding methods to decrease noise in the preprocessing step. We then applied a max-pooling technique with filter sizes of 2 x 1 and 5 x 1 within a 3-layer convolutional neural network to estimate BP. Our method was trained, validated, and tested using 2.4 million data samples from 49 patients in the intensive care unit. These samples, totaling 3.1 GB were obtained from the publicly accessible MIMIC database. As a result of a test with 480,000 data samples, the average root mean square error in BP estimation was 3.41, 5.80, and 2.78 mm Hg in the prediction of pulse pressure, systolic BP (SBP), and diastolic BP (DBP), respectively. The cumulative error percentage less than 5 mm Hg was 68% and 93% for SBP and DBP, respectively. In addition, the cumulative error percentage less than 15 mm Hg was 98% and 99% for SBP and DBP. Subsequently, we evaluated the impact of changes in input signal length (1 cycle vs. 30 s) and the introduction of noise on BP estimation results. The experimental results revealed that the length of the input signal did not significantly affect the performance of CNN-based analysis. When estimating BP using noise-added ECG signals, the mean absolute error (MAE) for SBP and DBP was 9.72 and 6.67 mm Hg, respectively. Meanwhile, when using noise-added PPG signals, the MAE for SBP and DBP was 26.85 and 14.00 mm Hg, respectively. Therefore, this study confirmed that using ECG signals rather than PPG signals is advantageous for noise reduction in a wearable environment. Besides, short sampling frames without calibration can be effective as input signals. Furthermore, it demonstrated that using a model suitable for information extraction rather than a specialized deep learning model for sequential data can yield satisfactory results in BP estimation.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Age estimation based on integrated convolutional neural network
    Feng Yanyan
    Zhou Yue
    Zeng Shangyou
    Pan Bing
    Li Daihui
    2019 18TH INTERNATIONAL SYMPOSIUM ON DISTRIBUTED COMPUTING AND APPLICATIONS FOR BUSINESS ENGINEERING AND SCIENCE (DCABES 2019), 2019, : 5 - 8
  • [32] Prediction of Uncertainty Estimation and Confidence Calibration Using Fully Convolutional Neural Network
    Gasmi, Karim
    Ben Ammar, Lassaad
    Elshammari, Hmoud
    Yahya, Fadwa
    CMC-COMPUTERS MATERIALS & CONTINUA, 2023, 75 (02): : 2557 - 2573
  • [33] Calibration-free deep optics for depth estimation with precise simulation
    Zhuge Z.
    Xu H.
    Chen S.
    Xu J.
    Li Q.
    Feng H.
    Xu Z.
    Chen Y.
    Optics and Lasers in Engineering, 2024, 180
  • [34] Continuous Blood Pressure Estimation using 1D Convolutional Neural Network and Attention Mechanism
    Seo Y.
    Lee J.
    Sunarya U.
    Lee K.
    Park C.
    IEIE Transactions on Smart Processing and Computing, 2022, 11 (03): : 169 - 173
  • [35] Cuffless blood pressure estimation from photoplethysmography using deep convolutional neural network and transfer learning
    Koparir, Hueseyin Murat
    Arslan, Ozkan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 93
  • [36] Calibration-Free Gaze Estimation Using Human Gaze Patterns
    Alnajar, Fares
    Gevers, Theo
    Valenti, Roberto
    Ghebreab, Sennay
    2013 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2013, : 137 - 144
  • [37] A Novel Convolutional Neural Network Deep Learning Implementation for Cuffless Heart Rate and Blood Pressure Estimation
    Bossavi, Geraud
    Yan, Rongguo
    Irfan, Muhammad
    APPLIED SCIENCES-BASEL, 2023, 13 (22):
  • [38] Blind, Cuff-less, Calibration-Free and Continuous Blood Pressure Estimation using Optimized Inductive Group Method of Data Handling
    Mohebbian, Mohammad Reza
    Anh Dinh
    Wahid, Khan
    Alam, Mohammad Sami
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [39] Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals
    Sanuki, Haruyuki
    Rui Fukui
    Inajima, Tsukasa
    Warisawa, Shin'ichi
    PROCEEDINGS OF THE 10TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2017, : 42 - 48
  • [40] Calibration-Free Footstep Frequency Estimation Using Structural Vibration
    Mirshekari, Mostafa
    Zhang, Pei
    Noh, Hae Young
    DYNAMICS OF CIVIL STRUCTURES, VOL 2, 2017, : 287 - 289