Accurate LC-MS/MS Analysis of Diacylglycerols in Human Plasma with Eliminating Matrix Effect by Phospholipids Using Fluorous Biphasic Extraction

被引:3
|
作者
Nishijo, Nao [1 ]
Hayama, Tadashi [1 ]
Tomita, Ryoko [1 ]
Fujioka, Toshihiro [1 ]
机构
[1] Fukuoka Univ, Fac Pharmaceut Sci, Johnan, Fukuoka 8140180, Japan
关键词
CHROMATOGRAPHY/TANDEM MASS-SPECTROMETRY; CHELATE AFFINITY EXTRACTION; LABELED INTERNAL STANDARDS; ION SUPPRESSION; SOLVENT; MS; NUCLEOTIDES; BIOANALYSIS; ENHANCEMENT; IONIZATION;
D O I
10.1021/acs.analchem.3c01998
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed an accurate method for determining diacylglycerols (DAGs) in human plasma using a fluorous biphasic liquid-liquid extraction method, followed by liquid chromatography with tandem mass spectrometry (LC-MS/MS) analysis. The lipid mixture in the plasma was first extracted with chloroform by using the Bligh-Dyer method. The resulting solution was subjected to fluorous biphasic liquid-liquid extraction to remove phospholipids, which are known to cause matrix effects during the LC-MS/MS analysis. In this method, phospholipids in a lipid mixture solution (nonfluorous solvent) were selectively extracted to tetradecafluorohexane (fluorous solvent) via the specificity of fluorous affinity by forming a complex with a perfluoro-polyether-carboxylic acid-lanthanum(III) salt. The remaining DAGs in the nonfluorous solvent could be directly injected into the LC system through the positive electrospray ionization-MS/MS mode. The removal rate of the phospholipids through the fluorous biphasic extraction was more than 99.9%; thus, the matrix-effect-eliminating analysis of DAGs in human plasma with LC-MS/MS was enabled. Furthermore, the applicability of this method and the possibility of using DAGs as biomarkers were evaluated by applying this method to human plasma samples obtained from major depressive disorder as a related disease.
引用
收藏
页码:14898 / 14904
页数:7
相关论文
共 50 条
  • [1] Analysis of valsartan, clindamycin and mesalamine in human plasma by LC-MS/MS using different extraction methodologies to overcome matrix effect
    Trivedi, Vikas
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    CHEMICAL PAPERS, 2020, 74 (12): : 4365 - 4378
  • [2] Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction elution conditions
    Lahaie, Mathieu
    Mess, Jean-Nicholas
    Furtado, Milton
    Garofolo, Fabio
    BIOANALYSIS, 2010, 2 (06) : 1011 - 1021
  • [3] Evaluation of oxidized phospholipids analysis by LC-MS/MS
    Khoury, Spiro
    Pouyet, Corinne
    Lyan, Bernard
    Pujos-Guillot, Estelle
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (02) : 633 - 647
  • [4] Evaluation of oxidized phospholipids analysis by LC-MS/MS
    Spiro Khoury
    Corinne Pouyet
    Bernard Lyan
    Estelle Pujos-Guillot
    Analytical and Bioanalytical Chemistry, 2018, 410 : 633 - 647
  • [5] Determination of Orelabrutinib in Human Plasma Using LC-MS/MS
    Zhao, Yang
    Guo, Yu-Jiao
    Chen, Xiang-Long
    Yang, Yan-Ling
    Ma, Hong
    Wang, Yong-Qing
    Sun, Lu-Ning
    THERAPEUTIC DRUG MONITORING, 2023, 45 (05) : 599 - 605
  • [6] Determination of ambroxol in human plasma using LC-MS/MS
    Kim, H
    Yoo, JY
    Han, SB
    Lee, HJ
    Lee, KR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (02) : 209 - 216
  • [7] Quantitative Analysis of Busulfan in Human Plasma by LC-MS–MS
    Lingyun Chen
    Zhifeng Zhou
    Mei Shen
    Ande Ma
    Chromatographia, 2009, 70 : 1727 - 1732
  • [8] Solid phase extraction and LC-MS/MS quantification of ibandronate in human plasma
    Moustapha, Moustapha E.
    Abdel-Gawad, Sherif A.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2020, 19 (06) : 1295 - 1302
  • [9] Analysis of valsartan, clindamycin and mesalamine in human plasma by LC–MS/MS using different extraction methodologies to overcome matrix effect
    Vikas Trivedi
    Priyanka A. Shah
    Pranav S. Shrivastav
    Mallika Sanyal
    Chemical Papers, 2020, 74 : 4365 - 4378
  • [10] Impact of electrospray ion source platforms on matrix effect due to plasma phospholipids in the determination of rivastigmine by LC-MS/MS
    Trivedi, Vikas
    Upadhyay, Vivek
    Yadav, Manish
    Shrivastav, Pranav S.
    Sanyal, Mallika
    BIOANALYSIS, 2014, 6 (17) : 2301 - 2316