ACCURACY OF THE DEXCOM G6 CONTINUOUS GLUCOSE MONITOR IN HOSPITALIZED PEDIATRIC PATIENTS WITH TYPE 1 DIABETES

被引:0
|
作者
Cobry, E. [1 ]
Pyle, L. [2 ]
Towers, L. [1 ]
Jost, E. [1 ]
Karami, A. [1 ]
Berget, C. [1 ]
Forlenza, G. [1 ]
Waterman, L. [1 ]
Wadwa, P. [1 ]
机构
[1] Univ Colorado Anschutz Med Campus, Barbara Davis Ctr, Aurora, CO USA
[2] Colorado Sch Publ Hlth Biostat & Informat, Aurora, CO USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
437
引用
收藏
页码:A205 / A206
页数:2
相关论文
共 50 条
  • [31] Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes
    Garg, Satish K.
    Kipnes, Mark
    Castorino, Kristin
    Bailey, Timothy S.
    Akturk, Halis Kaan
    Welsh, John B.
    Christiansen, Mark P.
    Balo, Andrew K.
    Brown, Sue A.
    Reid, Jennifer L.
    Beck, Stayce E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (06) : 373 - 380
  • [32] Pediatric Medicaid Patients With Type 1 Diabetes Benefit From Continuous Glucose Monitor Technology
    Ravi, Sonalee J.
    Coakley, Alexander
    Vigers, Tim
    Pyle, Laura
    Forlenza, Gregory P.
    Alonso, Todd
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (03): : 630 - 635
  • [33] The accuracy of the Guardian® RT continuous glucose monitor in children with type 1 diabetes
    Tansey, Michael
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (04) : 266 - 272
  • [34] Continuous Glucose Monitoring in the Intensive Care Unit Following Total Pancreatectomy with Islet Autotransplantation in Children: Establishing Accuracy of the Dexcom G6 Model
    Segev, Natalie
    Hornung, Lindsey N.
    Tellez, Siobhan E.
    Courter, Joshua D.
    Lawson, Sarah A.
    Nathan, Jaimie D.
    Abu-El-Haija, Maisam
    Elder, Deborah A.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [35] Effectiveness of real-time continuous glucose monitoring (Dexcom G6) among cardiac surgery patients: a randomised controlled trial
    Moon, S. -J.
    Kim, M. -S.
    Lee, H. -E.
    Lee, Y. -W.
    Lee, S. -J.
    Chung, E. -S.
    Park, C. -Y.
    DIABETOLOGIA, 2024, 67 : S391 - S392
  • [36] Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus
    Levitt, David L.
    Spanakis, Elias K.
    Ryan, Kathleen A.
    Silver, Kristi D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (01) : 32 - 38
  • [37] Omnipod 5 outcomes comparing Dexcom G6 and Freestyle Libre 2 plus users in adults with type 1 diabetes
    Stimson, Roland H.
    Dover, Anna R.
    Lyall, Marcus J.
    Kyle, Catriona J.
    Wright, Rohana J.
    McRobert, Gayle
    Strachan, Mark W. J.
    Gibb, Fraser W.
    DIABETIC MEDICINE, 2025, 42 (03)
  • [38] Performance of the Dexcom G6 Continuous Glucose Monitoring System During Cardiac Surgery Using Hypothermic Extracorporeal Circulation
    Herzig, David
    Vettoretti, Martina
    Guensch, Dominik P.
    Melmer, Andreas
    Schuerch, Daniel
    Roos, Jonathan
    Goerg, Arna M. C.
    Krutkyte, Gabija
    Cecchini, Luca
    Facchinetti, Andrea
    Vogt, Andreas P.
    Bally, Lia
    DIABETES CARE, 2023, 46 (04) : 864 - 867
  • [39] Long-Term Cost-Effectiveness the Dexcom G6 Real-Time Continuous Glucose Monitoring System Compared with Self-Monitoring of Blood Glucose in People with Type 1 Diabetes in France
    Stéphane Roze
    John J. Isitt
    Jayne Smith-Palmer
    Peter Lynch
    Brigitte Klinkenbijl
    Gerald Zammit
    Pierre-Yves Benhamou
    Diabetes Therapy, 2021, 12 : 235 - 246
  • [40] Modeling the error of factory-calibrated continuous glucose monitoring sensors: application to Dexcom G6 sensor data
    Vettoretti, Martina
    Del Favero, Simone
    Sparacino, Giovanni
    Facchinetti, Andrea
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 750 - 753